DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive
DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive
Part #: DC3R-12D-4X-010-DN Manufactured by: Reliance Electric

DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive

Regular price
$2,269.00
Sale price
$2,269.00
Regular price
Never Used Surplus
1 in Stock
Product Overview
The DC3R-12D-4X-010-DN, part of the Reliance Electric DC3 series, is a regenerative drive enclosed in a NEMA 12/4/4x encl...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
Product comes with IQElectro 2-Year Warranty
Warranty for item #: DC3R-12D-4X-010-DN
IQElectro International provides a 2-year warranty on every product we offer. Our complimentary 2-year warranty ensures that every IQElectro purchase is a trustworthy and reliable investment in the future of your company.
IQElectro is NOT an authorized distributor for Reliance Electric
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive
    DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive
DC3R-12D-4X-010-DN | Reliance Electric DC3 1 Phase Motor Controller Drive
Return/Exchange within 30-Days.
If any product is damaged upon delivery, you may request an Exchange or Refund within 30 days of receiving your order.
2-3-Day Free Shipping
"IQElectro provides free shipping within 2-3 days from the moment the order is placed on our website.

Product Description P/N: DC3R-12D-4X-010-DN

Description / Specifications

Description 

The DC3R-12D-4X-010-DN is a Reliance Electric DC3 series regenerative drive enclosed in a NEMA 12/4/4x enclosure. The "DN" designation indicates the inclusion of features such as jog, cyclic reversing by limit-switches, and independent forward/reverse speed pots. Additionally, the drive incorporates separate potentiometers for minimum and maximum speed, forward and reverse torque, forward and reverse acceleration, IR drop compensation, deadband compensation, and tachometer feedback. The instruction manual for this drive is D2-3453, and it does not require an additional heat sink. Reliance Electric drives comply with CE standards. 

Regenerative drives operate in 4 quadrants, facilitating motor torque opposite to motor rotation. These drives eliminate the need for contactors, switches, brake resistors, or inhibit plugs for motor reversal. They also effectively control overhauling loads and accelerate load deceleration. Troubleshooting issues such as motor speed discrepancies, pulsing or surging under load, and blown line fuses are addressed in the user manual. It is crucial to verify AC line voltage alignment with the drive nameplate and ensure proper sizing of the line fuse. Terminal connections must align with those specified in the user manual. Troubleshooting should not be attempted while AC power is applied. 

 

  

Technical Specifications 

Part # 

DC3R-12D-4X-010-DN 

Category 

Drives 

Subcategory 

Drive 

Manufacturer 

Reliance Electric 

Series 

DC3 

HP 

0.25/2 HP 

Input Voltage 

115/230 VAC 

Phase 

1 Phase 

 


Information About DC3R-12D-4X-010-DN

The DC3R-12D-4X-010-DN, belonging to the Reliance Electric DC3 series, is a regenerative drive housed in a NEMA 12/4/4x enclosure denoted by the "4X" designation. Featuring "DN" attributes, this drive incorporates functionalities such as jog, cyclic reversing by limit-switches, and independent forward/reverse speed pots. Additionally, it includes separate potentiometers catering to minimum and maximum speed, forward and reverse torque, forward and reverse acceleration, IR drop compensation, deadband compensation, and tachometer feedback. The instruction manual for this drive is D2-3453, and it does not necessitate an additional heat sink. Reliance Electric drives adhere to CE compliance standards. 

Regenerative drives operate across 4 quadrants, enabling motor torque direction opposite to motor rotation. These drives offer motor reversal capabilities without the need for contactors, switches, brake resistors, or inhibit plugs. Moreover, they effectively manage overhauling loads and expedite load deceleration beyond the speed achievable through coasting. The user manual comprehensively addresses troubleshooting scenarios, encompassing issues like failure to achieve desired motor speed, motor running excessively fast, motor failure despite intact line fuse, motor pulsing or surging under load, and blown line fuses. It is imperative to verify AC line voltage alignment with the drive nameplate and confirm proper sizing of the line fuse. Furthermore, ensuring consistency of terminal connections with those delineated in the user manual is crucial. Troubleshooting activities should abstain from execution when AC power is applied to the equipment. 

 

Manufacturer information

Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.

Warrany image

IQElectro 2 Year Warranty

IQElectro offers a 2-Year Warranty on all our products. This complimentary two-year warranty ensures that every purchase from IQElectro is a secure investment in the future of your company.
Warranty Terms and Conditions
warningIQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses. Some hardware products may contain software and firmware and may not be legally operated without first obtaining an appropriate license from the manufacturer. IQElectro makes no representation as to whether a product will or will not have software or firmware and, if it does, whether the software or firmware is the revision level that you need for your application. IQElectro also makes no representations as to your ability or right to download or otherwise obtain software or firmware for the product from the Original Manufacturer, its distributors, or any other source. IQElectro also makes no representations as to your right to install any such software or firmware on the product. IQElectro will not obtain or supply software or firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing software or firmware. Customer acknowledges and agrees that IQElectro DOES NOT provide any software, firmware, operating system, or right-to-use licenses with the products it sells. Customers understand and agree that proper software (firmware) licensing, maintenance, and upgrades are subject to the applicable manufacturer's Licensing Agreement or similar document. Disclaimer Policy.
Description / Specifications

Description 

The DC3R-12D-4X-010-DN is a Reliance Electric DC3 series regenerative drive enclosed in a NEMA 12/4/4x enclosure. The "DN" designation indicates the inclusion of features such as jog, cyclic reversing by limit-switches, and independent forward/reverse speed pots. Additionally, the drive incorporates separate potentiometers for minimum and maximum speed, forward and reverse torque, forward and reverse acceleration, IR drop compensation, deadband compensation, and tachometer feedback. The instruction manual for this drive is D2-3453, and it does not require an additional heat sink. Reliance Electric drives comply with CE standards. 

Regenerative drives operate in 4 quadrants, facilitating motor torque opposite to motor rotation. These drives eliminate the need for contactors, switches, brake resistors, or inhibit plugs for motor reversal. They also effectively control overhauling loads and accelerate load deceleration. Troubleshooting issues such as motor speed discrepancies, pulsing or surging under load, and blown line fuses are addressed in the user manual. It is crucial to verify AC line voltage alignment with the drive nameplate and ensure proper sizing of the line fuse. Terminal connections must align with those specified in the user manual. Troubleshooting should not be attempted while AC power is applied. 

 

  

Technical Specifications 

Part # 

DC3R-12D-4X-010-DN 

Category 

Drives 

Subcategory 

Drive 

Manufacturer 

Reliance Electric 

Series 

DC3 

HP 

0.25/2 HP 

Input Voltage 

115/230 VAC 

Phase 

1 Phase 

 


Information About DC3R-12D-4X-010-DN

The DC3R-12D-4X-010-DN, belonging to the Reliance Electric DC3 series, is a regenerative drive housed in a NEMA 12/4/4x enclosure denoted by the "4X" designation. Featuring "DN" attributes, this drive incorporates functionalities such as jog, cyclic reversing by limit-switches, and independent forward/reverse speed pots. Additionally, it includes separate potentiometers catering to minimum and maximum speed, forward and reverse torque, forward and reverse acceleration, IR drop compensation, deadband compensation, and tachometer feedback. The instruction manual for this drive is D2-3453, and it does not necessitate an additional heat sink. Reliance Electric drives adhere to CE compliance standards. 

Regenerative drives operate across 4 quadrants, enabling motor torque direction opposite to motor rotation. These drives offer motor reversal capabilities without the need for contactors, switches, brake resistors, or inhibit plugs. Moreover, they effectively manage overhauling loads and expedite load deceleration beyond the speed achievable through coasting. The user manual comprehensively addresses troubleshooting scenarios, encompassing issues like failure to achieve desired motor speed, motor running excessively fast, motor failure despite intact line fuse, motor pulsing or surging under load, and blown line fuses. It is imperative to verify AC line voltage alignment with the drive nameplate and confirm proper sizing of the line fuse. Furthermore, ensuring consistency of terminal connections with those delineated in the user manual is crucial. Troubleshooting activities should abstain from execution when AC power is applied to the equipment. 

 

Manufacturer information

Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)