DR45AT-1000-00-000-0-00000E-0 | Honeywell 12-Inch Single-Channel Chart Recorder 120/240 VAC
- Regular price
 - $2,964.00
 - Sale price
 - $2,964.00
 - Regular price
 - 
        
 
Couldn't load pickup availability
Do you need help?
Product Description P/N: DR45AT-1000-00-000-0-00000E-0
Description
The Honeywell DR45AT-1000-00-000-0-00000E-0 is a robust industrial chart recorder designed for accurate single-channel process data logging. Operating on 120/240 VAC power at 50–60 Hz, it features a large 12-inch circular chart face for clear data visualization. This model is built for reliable performance in demanding environments requiring long-term paper-based recording.
Technical Specifications
| Condition | New/Never Used Surplus | 
| Brand | Honeywell | 
| Category | Data Control System | 
| Part Number | DR45AT-1000-00-000-0-00000E-0 | 
| Subcategory | Chart Recorder | 
| Chart Size | 12 in circular | 
| Number of Channels | 1 | 
| Power Supply | 120/240 VAC | 
| Frequency | 50–60 Hz | 
| Display Window | Glass | 
| Chart Type | Paper circular chart | 
| Recording Type | Mechanical pen drive | 
| Operating Environment | Industrial process monitoring | 
| Mounting Style | Panel mount | 
| Input Type | Configurable for process signals | 
| Construction | Heavy-duty industrial-grade | 
| Maintenance | Easy chart replacement | 
| Weight | 14.27 lbs | 
Information About DR45AT-1000-00-000-0-00000E-0
The DR45AT-1000-00-000-0-00000E-0 is part of Honeywell’s DR45A series of industrial chart recorders, known for their durability and precision in process monitoring applications. It offers a single-channel configuration, making it ideal for recording one primary variable such as temperature, pressure, or flow. With its large glass-window front and 12-inch chart, it provides excellent readability for on-site operators. Designed for use in manufacturing plants, laboratories, and industrial facilities, it supports continuous monitoring and archival record-keeping for regulatory and quality assurance purposes.
Key Features:
- Large 12-Inch Chart Face: Provides enhanced visibility for recorded data.
 - Single-Channel Recording: Suitable for logging one primary process variable.
 - Glass Window: Ensures chart protection while allowing easy visual inspection.
 - Dual Voltage Operation: Compatible with 120/240 VAC power at 50–60 Hz.
 - Durable Construction: Built for industrial environments with continuous operation.
 - Accurate Data Capture: Maintains consistent chart movement for reliable readings.
 - Clear Marking System: Supports precise trend tracking and regulatory compliance.
 - Easy Chart Replacement: Simplifies maintenance and reduces downtime.
 
The DR45AT-1000-00-000-0-00000E-0 delivers the reliability and precision required for critical process monitoring in industrial applications.
Description
The Honeywell DR45AT-1000-00-000-0-00000E-0 is a robust industrial chart recorder designed for accurate single-channel process data logging. Operating on 120/240 VAC power at 50–60 Hz, it features a large 12-inch circular chart face for clear data visualization. This model is built for reliable performance in demanding environments requiring long-term paper-based recording.
Technical Specifications
| Condition | New/Never Used Surplus | 
| Brand | Honeywell | 
| Category | Data Control System | 
| Part Number | DR45AT-1000-00-000-0-00000E-0 | 
| Subcategory | Chart Recorder | 
| Chart Size | 12 in circular | 
| Number of Channels | 1 | 
| Power Supply | 120/240 VAC | 
| Frequency | 50–60 Hz | 
| Display Window | Glass | 
| Chart Type | Paper circular chart | 
| Recording Type | Mechanical pen drive | 
| Operating Environment | Industrial process monitoring | 
| Mounting Style | Panel mount | 
| Input Type | Configurable for process signals | 
| Construction | Heavy-duty industrial-grade | 
| Maintenance | Easy chart replacement | 
| Weight | 14.27 lbs | 
Information About DR45AT-1000-00-000-0-00000E-0
The DR45AT-1000-00-000-0-00000E-0 is part of Honeywell’s DR45A series of industrial chart recorders, known for their durability and precision in process monitoring applications. It offers a single-channel configuration, making it ideal for recording one primary variable such as temperature, pressure, or flow. With its large glass-window front and 12-inch chart, it provides excellent readability for on-site operators. Designed for use in manufacturing plants, laboratories, and industrial facilities, it supports continuous monitoring and archival record-keeping for regulatory and quality assurance purposes.
Key Features:
- Large 12-Inch Chart Face: Provides enhanced visibility for recorded data.
 - Single-Channel Recording: Suitable for logging one primary process variable.
 - Glass Window: Ensures chart protection while allowing easy visual inspection.
 - Dual Voltage Operation: Compatible with 120/240 VAC power at 50–60 Hz.
 - Durable Construction: Built for industrial environments with continuous operation.
 - Accurate Data Capture: Maintains consistent chart movement for reliable readings.
 - Clear Marking System: Supports precise trend tracking and regulatory compliance.
 - Easy Chart Replacement: Simplifies maintenance and reduces downtime.
 
The DR45AT-1000-00-000-0-00000E-0 delivers the reliability and precision required for critical process monitoring in industrial applications.