Product Description P/N: 1950-00-2F
Description
The Dwyer 1950-00-2F is an explosion-proof differential pressure switch with an adjustable set-point range of 0.07–0.15 inches w.c. It provides SPDT switching for monitoring small pressure differences in air and compatible noncombustible gas systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | 1950-00-2F |
| Subcategory | Pressure Switches |
| Series | 1950 |
| Pressure Type | Differential |
| Adjustable Set-Point Range | 0.07–0.15 inches w.c. |
| Service | Air and compatible noncombustible gases |
| Switch Type | SPDT |
| Electrical Rating | 15 A at 125, 250, or 480 VAC, 60 Hz |
| Approximate Deadband | 0.04 inch w.c. at minimum set point; 0.05 inch w.c. at maximum set point |
| Continuous Pressure Limit | 45 inches w.c. |
| Surge Pressure Limit | 10 psi |
| Process Connections | 1/8-inch female NPT |
| Conduit Connection | 1/2-inch female NPT |
| Electrical Connections | Three screw terminals: common, NO, NC |
| Enclosure Rating | NEMA 3 / IP54; NEMA 7 and 9 |
| Operating Temperature | −40°F to +140°F (−40°C to +60°C) |
| Weight | 3.25 lb (1.5 kg) |
Information About 1950-00-2F
The 1950-00-2F is part of Dwyer’s Series 1950 differential pressure switches. Its integrated weatherproof housing contains the diaphragm-operated switching mechanism and screw terminals. An external adjustment screw allows set-point changes without removing the enclosure cover. Separate high- and low-pressure ports connect to compatible fittings, with installation requiring the diaphragm to remain vertical.
Key Features:
- Low-Pressure Switching: Detects differential pressure within a 0.07–0.15-inch w.c. set-point range.
- SPDT Contacts: Provides common, normally open, and normally closed connections.
- External Adjustment: Set point can be changed without opening the housing.
- Dual Pressure Ports: Separate connections accommodate high- and low-pressure sensing lines.
- Explosion-Proof Housing: Supports installation within the specified hazardous-location classifications.
- Weatherproof Construction: O-ring cover seal and drain plug support outdoor applications.
- Screw Terminals: Provides accessible field wiring connections behind the front cover.
The 1950-00-2F delivers the reliability and precision required for low differential pressure switching in HVAC and compatible process systems.
Description
The Dwyer 1950-00-2F is an explosion-proof differential pressure switch with an adjustable set-point range of 0.07–0.15 inches w.c. It provides SPDT switching for monitoring small pressure differences in air and compatible noncombustible gas systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | 1950-00-2F |
| Subcategory | Pressure Switches |
| Series | 1950 |
| Pressure Type | Differential |
| Adjustable Set-Point Range | 0.07–0.15 inches w.c. |
| Service | Air and compatible noncombustible gases |
| Switch Type | SPDT |
| Electrical Rating | 15 A at 125, 250, or 480 VAC, 60 Hz |
| Approximate Deadband | 0.04 inch w.c. at minimum set point; 0.05 inch w.c. at maximum set point |
| Continuous Pressure Limit | 45 inches w.c. |
| Surge Pressure Limit | 10 psi |
| Process Connections | 1/8-inch female NPT |
| Conduit Connection | 1/2-inch female NPT |
| Electrical Connections | Three screw terminals: common, NO, NC |
| Enclosure Rating | NEMA 3 / IP54; NEMA 7 and 9 |
| Operating Temperature | −40°F to +140°F (−40°C to +60°C) |
| Weight | 3.25 lb (1.5 kg) |
Information About 1950-00-2F
The 1950-00-2F is part of Dwyer’s Series 1950 differential pressure switches. Its integrated weatherproof housing contains the diaphragm-operated switching mechanism and screw terminals. An external adjustment screw allows set-point changes without removing the enclosure cover. Separate high- and low-pressure ports connect to compatible fittings, with installation requiring the diaphragm to remain vertical.
Key Features:
- Low-Pressure Switching: Detects differential pressure within a 0.07–0.15-inch w.c. set-point range.
- SPDT Contacts: Provides common, normally open, and normally closed connections.
- External Adjustment: Set point can be changed without opening the housing.
- Dual Pressure Ports: Separate connections accommodate high- and low-pressure sensing lines.
- Explosion-Proof Housing: Supports installation within the specified hazardous-location classifications.
- Weatherproof Construction: O-ring cover seal and drain plug support outdoor applications.
- Screw Terminals: Provides accessible field wiring connections behind the front cover.
The 1950-00-2F delivers the reliability and precision required for low differential pressure switching in HVAC and compatible process systems.