Product Description P/N: CDT-2N40-LCD
Description
The Dwyer CDT-2N40-LCD is a wall-mounted carbon dioxide transmitter with an LCD for monitoring indoor air quality. Its NDIR sensor measures 0–2000 ppm CO2 and provides a selectable analog output for demand-controlled ventilation and building automation systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | CDT-2N40-LCD |
| Subcategory | CO2 Sensors |
| Series | CDT |
| Measured Gas | Carbon dioxide |
| Sensing Technology | Non-dispersive infrared (NDIR) |
| CO2 Measurement Range | 0–2000 ppm |
| CO2 Accuracy | ±40 ppm +3% of reading, subject to manufacturer’s operating conditions |
| Response Time | 2 minutes for a 90% step change |
| Display | Integral LCD |
| CO2 Output | Selectable 4–20 mA, 0–5 VDC, or 0–10 VDC |
| Supply Voltage | 16–35 VDC or 19–28 VAC |
| Power Consumption | 2 W average; 3.75 W peak |
| Operating Temperature | 0°C to +50°C |
| Operating Humidity | 0–85% RH, noncondensing |
| Mounting | North American-style wall mount |
| Weight | 125 g (4.4 oz) |
Information About CDT-2N40-LCD
The CDT-2N40-LCD is part of Dwyer’s CDT series of carbon dioxide and temperature instruments. This configuration uses a North American-style wall housing with backplate electrical connections. Automatic Baseline Correction compensates for sensor drift, while barometric pressure adjustment supports measurement setup. The model provides a CO2 output without a separate temperature output or humidity output.
Key Features:
- NDIR Measurement: Uses non-dispersive infrared technology to detect carbon dioxide.
- CO2 Range: Measures concentrations from 0 to 2000 ppm.
- Integral LCD: Provides local indication for occupied-space monitoring.
- Selectable Output: Supports 4–20 mA, 0–5 VDC, or 0–10 VDC signals.
- Drift Compensation: Automatic Baseline Correction helps maintain sensor performance.
- Wall Installation: North American-style housing mounts within the monitored space.
- Backplate Wiring: Electrical connections on the backplate simplify installation.
- Button Lockout: Internal selection can restrict changes through the front controls.
The CDT-2N40-LCD delivers the reliability and precision required for indoor CO2 monitoring and demand-controlled ventilation.
Description
The Dwyer CDT-2N40-LCD is a wall-mounted carbon dioxide transmitter with an LCD for monitoring indoor air quality. Its NDIR sensor measures 0–2000 ppm CO2 and provides a selectable analog output for demand-controlled ventilation and building automation systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | CDT-2N40-LCD |
| Subcategory | CO2 Sensors |
| Series | CDT |
| Measured Gas | Carbon dioxide |
| Sensing Technology | Non-dispersive infrared (NDIR) |
| CO2 Measurement Range | 0–2000 ppm |
| CO2 Accuracy | ±40 ppm +3% of reading, subject to manufacturer’s operating conditions |
| Response Time | 2 minutes for a 90% step change |
| Display | Integral LCD |
| CO2 Output | Selectable 4–20 mA, 0–5 VDC, or 0–10 VDC |
| Supply Voltage | 16–35 VDC or 19–28 VAC |
| Power Consumption | 2 W average; 3.75 W peak |
| Operating Temperature | 0°C to +50°C |
| Operating Humidity | 0–85% RH, noncondensing |
| Mounting | North American-style wall mount |
| Weight | 125 g (4.4 oz) |
Information About CDT-2N40-LCD
The CDT-2N40-LCD is part of Dwyer’s CDT series of carbon dioxide and temperature instruments. This configuration uses a North American-style wall housing with backplate electrical connections. Automatic Baseline Correction compensates for sensor drift, while barometric pressure adjustment supports measurement setup. The model provides a CO2 output without a separate temperature output or humidity output.
Key Features:
- NDIR Measurement: Uses non-dispersive infrared technology to detect carbon dioxide.
- CO2 Range: Measures concentrations from 0 to 2000 ppm.
- Integral LCD: Provides local indication for occupied-space monitoring.
- Selectable Output: Supports 4–20 mA, 0–5 VDC, or 0–10 VDC signals.
- Drift Compensation: Automatic Baseline Correction helps maintain sensor performance.
- Wall Installation: North American-style housing mounts within the monitored space.
- Backplate Wiring: Electrical connections on the backplate simplify installation.
- Button Lockout: Internal selection can restrict changes through the front controls.
The CDT-2N40-LCD delivers the reliability and precision required for indoor CO2 monitoring and demand-controlled ventilation.