Dwyer TDFS2-1-P-06 Thermal Dispersion Flow Switch with Adjustable Set Point and Complementary Outputs
- Regular price
- $515.00
- Sale price
- $515.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: TDFS2-1-P-06
Description
The Dwyer TDFS2-1-P-06 is a thermal dispersion flow switch for detecting flow above or below an adjustable threshold in compatible water-based fluids. Designed for 1/2- to 1-1/2-inch piping, it combines a stainless-steel sensing probe with complementary NPN outputs and LED status indication.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | TDFS2-1-P-06 |
| Subcategory | Flow Switches |
| Series | TDFS2 |
| Sensing Technology | Thermal dispersion |
| Service | Compatible water-based fluids |
| Nominal Pipe Range | 1/2–1-1/2 inches (15–40 mm) |
| Wetted Material | 316 stainless steel |
| Process Connection | 1/2-inch male NPT |
| Set-Point Range | 0.5–10 ft/s (0.15–3.0 m/s) |
| Supply Voltage | 9–24 VDC |
| Outputs | One NO NPN and one NC NPN |
| Switching Current | 400 mA; derate 5 mA/°C above 23°C |
| Current Consumption | 93 mA average; 300 mA peak |
| Maximum Pressure | 300 psig (20.67 bar) |
| Ambient and Process Temperature | −15°C to +60°C |
| Cable / Enclosure | 6 ft (1.83 m) PVC-jacketed cable with gland; NEMA 4X / IP65 |
| Weight | 1.3 lb (0.59 kg) |
Information About TDFS2-1-P-06
The TDFS2-1-P-06 is part of Dwyer’s TDFS2 thermal dispersion flow switch series. Its sensing mechanism operates without a moving paddle or vane. A supplied magnet allows field adjustment of the switching point without opening the housing. This configuration includes a 1/2-inch male NPT process connection and a six-foot PVC-jacketed cable secured through a cable gland.
Key Features:
- Thermal Sensing: Detects flow using heat transfer rather than mechanical paddle movement.
- Adjustable Threshold: Supports set points from 0.5 to 10 ft/s.
- Complementary Outputs: Provides one normally open and one normally closed NPN output.
- Visual Indication: Two LEDs display switch status.
- Stainless-Steel Probe: Uses 316 stainless steel for wetted components.
- Compact Pipe Compatibility: Designed for nominal pipe sizes from 1/2 to 1-1/2 inches.
- Protected Housing: Meets NEMA 4X and IP65 enclosure requirements.
- Electrical Protection: Includes resettable fuse protection and reverse-polarity protection.
The TDFS2-1-P-06 delivers the reliability and precision required for flow monitoring in chillers, water-heating equipment, and liquid transfer systems.
Description
The Dwyer TDFS2-1-P-06 is a thermal dispersion flow switch for detecting flow above or below an adjustable threshold in compatible water-based fluids. Designed for 1/2- to 1-1/2-inch piping, it combines a stainless-steel sensing probe with complementary NPN outputs and LED status indication.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Dwyer |
| Category | Sensors & Switches |
| Part Number | TDFS2-1-P-06 |
| Subcategory | Flow Switches |
| Series | TDFS2 |
| Sensing Technology | Thermal dispersion |
| Service | Compatible water-based fluids |
| Nominal Pipe Range | 1/2–1-1/2 inches (15–40 mm) |
| Wetted Material | 316 stainless steel |
| Process Connection | 1/2-inch male NPT |
| Set-Point Range | 0.5–10 ft/s (0.15–3.0 m/s) |
| Supply Voltage | 9–24 VDC |
| Outputs | One NO NPN and one NC NPN |
| Switching Current | 400 mA; derate 5 mA/°C above 23°C |
| Current Consumption | 93 mA average; 300 mA peak |
| Maximum Pressure | 300 psig (20.67 bar) |
| Ambient and Process Temperature | −15°C to +60°C |
| Cable / Enclosure | 6 ft (1.83 m) PVC-jacketed cable with gland; NEMA 4X / IP65 |
| Weight | 1.3 lb (0.59 kg) |
Information About TDFS2-1-P-06
The TDFS2-1-P-06 is part of Dwyer’s TDFS2 thermal dispersion flow switch series. Its sensing mechanism operates without a moving paddle or vane. A supplied magnet allows field adjustment of the switching point without opening the housing. This configuration includes a 1/2-inch male NPT process connection and a six-foot PVC-jacketed cable secured through a cable gland.
Key Features:
- Thermal Sensing: Detects flow using heat transfer rather than mechanical paddle movement.
- Adjustable Threshold: Supports set points from 0.5 to 10 ft/s.
- Complementary Outputs: Provides one normally open and one normally closed NPN output.
- Visual Indication: Two LEDs display switch status.
- Stainless-Steel Probe: Uses 316 stainless steel for wetted components.
- Compact Pipe Compatibility: Designed for nominal pipe sizes from 1/2 to 1-1/2 inches.
- Protected Housing: Meets NEMA 4X and IP65 enclosure requirements.
- Electrical Protection: Includes resettable fuse protection and reverse-polarity protection.
The TDFS2-1-P-06 delivers the reliability and precision required for flow monitoring in chillers, water-heating equipment, and liquid transfer systems.