Product Description P/N: LT360033
Description
The Eaton LT360033 is a molded case circuit breaker trip unit designed to provide reliable overcurrent protection control within Eaton Series C breaker systems. This Eaton part number LT360033 supports applications rated up to 600 amps and is engineered for integration with compatible J-K frame molded case circuit breakers. It delivers accurate trip functionality to help protect electrical distribution equipment from overload and fault conditions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton |
| Category | Circuit Breaker |
| Part Number | LT360033 |
| Subcategory | Circuit Breaker Trip |
| Product Type | Molded Case Circuit Breaker Trip Unit |
| Series | Series C |
| Circuit Breaker Type | LT |
| Frame Compatibility | Frame J-K |
| Number of Poles | Three-pole |
| Trip Type | T38 |
| Amperage Rating | 600 A |
| Application | Overcurrent trip control for molded case circuit breakers |
| HACR Rating | HACR Rated |
| Certifications | Refer to manufacturer |
| Dimensions (L × W × H) | 8.5 × 4.63 × 4.38 in |
| Weight | 2.66 lb |
Information About LT360033
The LT360033 is a circuit breaker accessory trip unit manufactured by Eaton for use with Series C molded case circuit breakers. It is designed to control the tripping mechanism of compatible breakers and provide dependable protection against electrical overloads and short circuits. The unit is intended for J-K frame breakers and supports three-pole configurations commonly used in industrial and commercial three-phase power systems. With a T38 trip type and robust internal design, it helps ensure stable protection performance within switchboards, panelboards, and distribution assemblies.
Key Features:
- 600 Amp Trip Rating: Designed for breaker systems protecting circuits up to 600 amps.
- Series C Compatibility: Built for Eaton Series C molded case circuit breaker platforms.
- J-K Frame Integration: Compatible with breakers using J-K frame sizes.
- T38 Trip Unit Design: Provides dependable control of breaker tripping under overload and fault conditions.
- Three-Pole System Support: Suitable for three-phase electrical distribution systems.
- Replacement or Upgrade Component: Can be installed as an accessory to maintain or restore breaker protection functionality.
- Industrial-Grade Construction: Designed for reliable operation in demanding electrical environments.
- HACR Application Compatibility: Suitable for HVAC and refrigeration equipment rated under HACR guidelines.
The LT360033 delivers the reliability and precision required for accurate overcurrent protection control within industrial circuit breaker systems.
Description
The Eaton LT360033 is a molded case circuit breaker trip unit designed to provide reliable overcurrent protection control within Eaton Series C breaker systems. This Eaton part number LT360033 supports applications rated up to 600 amps and is engineered for integration with compatible J-K frame molded case circuit breakers. It delivers accurate trip functionality to help protect electrical distribution equipment from overload and fault conditions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton |
| Category | Circuit Breaker |
| Part Number | LT360033 |
| Subcategory | Circuit Breaker Trip |
| Product Type | Molded Case Circuit Breaker Trip Unit |
| Series | Series C |
| Circuit Breaker Type | LT |
| Frame Compatibility | Frame J-K |
| Number of Poles | Three-pole |
| Trip Type | T38 |
| Amperage Rating | 600 A |
| Application | Overcurrent trip control for molded case circuit breakers |
| HACR Rating | HACR Rated |
| Certifications | Refer to manufacturer |
| Dimensions (L × W × H) | 8.5 × 4.63 × 4.38 in |
| Weight | 2.66 lb |
Information About LT360033
The LT360033 is a circuit breaker accessory trip unit manufactured by Eaton for use with Series C molded case circuit breakers. It is designed to control the tripping mechanism of compatible breakers and provide dependable protection against electrical overloads and short circuits. The unit is intended for J-K frame breakers and supports three-pole configurations commonly used in industrial and commercial three-phase power systems. With a T38 trip type and robust internal design, it helps ensure stable protection performance within switchboards, panelboards, and distribution assemblies.
Key Features:
- 600 Amp Trip Rating: Designed for breaker systems protecting circuits up to 600 amps.
- Series C Compatibility: Built for Eaton Series C molded case circuit breaker platforms.
- J-K Frame Integration: Compatible with breakers using J-K frame sizes.
- T38 Trip Unit Design: Provides dependable control of breaker tripping under overload and fault conditions.
- Three-Pole System Support: Suitable for three-phase electrical distribution systems.
- Replacement or Upgrade Component: Can be installed as an accessory to maintain or restore breaker protection functionality.
- Industrial-Grade Construction: Designed for reliable operation in demanding electrical environments.
- HACR Application Compatibility: Suitable for HVAC and refrigeration equipment rated under HACR guidelines.
The LT360033 delivers the reliability and precision required for accurate overcurrent protection control within industrial circuit breaker systems.