Edwards D02604000 APG100-XLC Corrosion-Resistant Active Pirani Vacuum Gauge
- Regular price
- $1,319.00
- Sale price
- $1,319.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: D02604000
Description
The Edwards D02604000 is an APG100-XLC active Pirani vacuum gauge designed for pressure monitoring from atmosphere down to 1 × 10⁻⁴ mbar. Its corrosion-resistant sensor configuration and NW25 connection support installation in compatible laboratory and industrial vacuum systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Edwards |
| Category | Vacuum Measurement |
| Part Number | D02604000 |
| Subcategory | Active Pirani Vacuum Gauges |
| Measurement Technology | Pirani thermal conductivity |
| Pressure Range | Atmosphere to 1 × 10⁻⁴ mbar |
| Vacuum Connection | NW25 / DN 25 ISO-KF |
| Sensor Version | Corrosion-resistant |
| Controller Compatibility | Edwards TIC and compatible active gauge controllers and displays |
| Typical Accuracy | ±15% below 10 mbar |
| Nominal Supply Voltage | 15–30 V DC |
| Power Consumption | 1 W |
| Nominal Output Signal | 0–10 V DC; pressure scaling of 1 V per decade |
| Setpoint Output | Open-collector transistor, rated 30 V DC, 100 mA |
| Operating Temperature | +5 to +60 °C |
| Storage Temperature | −30 to +70 °C |
| Maximum Bakeout Temperature | 150 °C with electronics removed |
| Enclosure Rating | IP40 |
| Weight | 0.22 lb |
Information About D02604000
The D02604000 is the NW25-flanged corrosion-resistant model in the Edwards APG100 series. Its compact assembly combines a replaceable sensor tube with removable electronics for component servicing. The gauge connects to Edwards TIC instrument controllers and other compatible active gauge controllers and displays. A pressure output scaled at one volt per decade supports integration with vacuum monitoring and control equipment.
Key Features:
- Extended Measurement Range: Measures pressure from atmosphere down to 1 × 10⁻⁴ mbar.
- Corrosion-Resistant Design: Uses the APG100-XLC sensor configuration for improved corrosion resistance.
- Controller Compatibility: Works with Edwards TIC instruments and compatible active gauge controllers and displays.
- Pressure Signal Output: Provides a logarithmic pressure signal scaled at one volt per decade.
- Replaceable Sensor Tube: Allows sensor replacement while retaining serviceable electronics.
- Adjustable Setpoint: Provides a configurable switching output for pressure-based control and interlocking.
- Status Indicator: Uses an LED to indicate normal operation and fault conditions.
- Bakeout Capability: Permits sensor tube bakeout up to 150 °C with the electronics removed.
The D02604000 delivers the reliability and precision required for vacuum pressure monitoring and pressure-based process control in laboratory and industrial systems.
Description
The Edwards D02604000 is an APG100-XLC active Pirani vacuum gauge designed for pressure monitoring from atmosphere down to 1 × 10⁻⁴ mbar. Its corrosion-resistant sensor configuration and NW25 connection support installation in compatible laboratory and industrial vacuum systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Edwards |
| Category | Vacuum Measurement |
| Part Number | D02604000 |
| Subcategory | Active Pirani Vacuum Gauges |
| Measurement Technology | Pirani thermal conductivity |
| Pressure Range | Atmosphere to 1 × 10⁻⁴ mbar |
| Vacuum Connection | NW25 / DN 25 ISO-KF |
| Sensor Version | Corrosion-resistant |
| Controller Compatibility | Edwards TIC and compatible active gauge controllers and displays |
| Typical Accuracy | ±15% below 10 mbar |
| Nominal Supply Voltage | 15–30 V DC |
| Power Consumption | 1 W |
| Nominal Output Signal | 0–10 V DC; pressure scaling of 1 V per decade |
| Setpoint Output | Open-collector transistor, rated 30 V DC, 100 mA |
| Operating Temperature | +5 to +60 °C |
| Storage Temperature | −30 to +70 °C |
| Maximum Bakeout Temperature | 150 °C with electronics removed |
| Enclosure Rating | IP40 |
| Weight | 0.22 lb |
Information About D02604000
The D02604000 is the NW25-flanged corrosion-resistant model in the Edwards APG100 series. Its compact assembly combines a replaceable sensor tube with removable electronics for component servicing. The gauge connects to Edwards TIC instrument controllers and other compatible active gauge controllers and displays. A pressure output scaled at one volt per decade supports integration with vacuum monitoring and control equipment.
Key Features:
- Extended Measurement Range: Measures pressure from atmosphere down to 1 × 10⁻⁴ mbar.
- Corrosion-Resistant Design: Uses the APG100-XLC sensor configuration for improved corrosion resistance.
- Controller Compatibility: Works with Edwards TIC instruments and compatible active gauge controllers and displays.
- Pressure Signal Output: Provides a logarithmic pressure signal scaled at one volt per decade.
- Replaceable Sensor Tube: Allows sensor replacement while retaining serviceable electronics.
- Adjustable Setpoint: Provides a configurable switching output for pressure-based control and interlocking.
- Status Indicator: Uses an LED to indicate normal operation and fault conditions.
- Bakeout Capability: Permits sensor tube bakeout up to 150 °C with the electronics removed.
The D02604000 delivers the reliability and precision required for vacuum pressure monitoring and pressure-based process control in laboratory and industrial systems.