Description
The Edwards Signaling 878EX-G5 is a heavy-duty vibrating horn designed to deliver high-decibel audible signaling in hazardous industrial environments. Manufactured by Edwards Signaling, the 878EX-G5 operates on 24 VAC and produces up to 110 dB of sound output for effective warning and emergency notification. Its corrosion-resistant construction and NEMA 4X enclosure make it suitable for demanding indoor and outdoor industrial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Edwards Signaling |
| Category | Audible Signaling |
| Part Number | 878EX-G5 |
| Subcategory | Vibrating Horn |
| Series | 878EX Series |
| Product Type | Heavy-Duty Vibrating Horn with Grill |
| Nominal Voltage | 24 VAC |
| Frequency | 50/60 Hz |
| Current Rating | 0.625 A |
| Power Rating | 15 VA |
| Sound Intensity | 110 dB at 1 m; 100 dB at 10 ft |
| Housing Material | Corrosion-Resistant Heat-Flowed Epoxy |
| Mounting | Wall Mount |
| Conduit Tapping Size | 3/4 in. |
| Enclosure Rating | NEMA 4X |
| Hazardous Location | Yes |
| Hazardous Area Classification | Class I Div. 1 & 2 Groups B, C, D; Class II Div. 1 & 2 Groups E, F, G; Class III |
| Approvals | UL |
| DC Coil Resistance | 5.2 Ω |
| Dimensions | 7-3/8 in. W × 4-3/16 in. D × 7-5/8 in. H |
| Application | Indoor/Outdoor, Mines, Petroleum Plants, Gas Plants, Grain Elevators, Flour Mills, Paper Mills, Textile Plants, Tankers |
| Weight | 11 lb (4.99 kg) |
Information About 878EX-G5
The 878EX-G5 is part of the Edwards Signaling 878EX Series of industrial audible signaling devices developed for use in hazardous and severe-duty environments. It features a corrosion-resistant heat-flowed epoxy housing with wall mounting and a 3/4-inch conduit entry for secure installation. The vibrating horn is intended for facilities such as petroleum plants, gas plants, mines, grain elevators, paper mills, textile plants, flour mills, and tankers where dependable audible warning is essential. Its rugged enclosure is designed to withstand harsh environmental conditions while providing consistent signaling performance in hazardous locations.
Key Features:
- High-Decibel Output: Produces up to 110 dB at 1 meter for clear audible warning.
- 24 VAC Operation: Designed for 24 VAC, 50/60 Hz industrial control systems.
- Heavy-Duty Vibrating Horn: Provides reliable mechanical audible signaling.
- Hazardous Location Application: Suitable for industrial hazardous environments requiring robust warning devices.
- NEMA 4X Enclosure: Protects against water, corrosion, dust, and harsh weather conditions.
- Corrosion-Resistant Housing: Constructed with heat-flowed epoxy for long service life.
- Flexible Installation: Wall-mounted design with 3/4-inch conduit tapping for convenient wiring.
- UL Listed: Certified to meet recognized industrial safety standards.
The 878EX-G5 delivers the reliability and precision required for hazardous-area audible warning, industrial safety notification, and emergency signaling applications.
Description
The Edwards Signaling 878EX-G5 is a heavy-duty vibrating horn designed to deliver high-decibel audible signaling in hazardous industrial environments. Manufactured by Edwards Signaling, the 878EX-G5 operates on 24 VAC and produces up to 110 dB of sound output for effective warning and emergency notification. Its corrosion-resistant construction and NEMA 4X enclosure make it suitable for demanding indoor and outdoor industrial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Edwards Signaling |
| Category | Audible Signaling |
| Part Number | 878EX-G5 |
| Subcategory | Vibrating Horn |
| Series | 878EX Series |
| Product Type | Heavy-Duty Vibrating Horn with Grill |
| Nominal Voltage | 24 VAC |
| Frequency | 50/60 Hz |
| Current Rating | 0.625 A |
| Power Rating | 15 VA |
| Sound Intensity | 110 dB at 1 m; 100 dB at 10 ft |
| Housing Material | Corrosion-Resistant Heat-Flowed Epoxy |
| Mounting | Wall Mount |
| Conduit Tapping Size | 3/4 in. |
| Enclosure Rating | NEMA 4X |
| Hazardous Location | Yes |
| Hazardous Area Classification | Class I Div. 1 & 2 Groups B, C, D; Class II Div. 1 & 2 Groups E, F, G; Class III |
| Approvals | UL |
| DC Coil Resistance | 5.2 Ω |
| Dimensions | 7-3/8 in. W × 4-3/16 in. D × 7-5/8 in. H |
| Application | Indoor/Outdoor, Mines, Petroleum Plants, Gas Plants, Grain Elevators, Flour Mills, Paper Mills, Textile Plants, Tankers |
| Weight | 11 lb (4.99 kg) |
Information About 878EX-G5
The 878EX-G5 is part of the Edwards Signaling 878EX Series of industrial audible signaling devices developed for use in hazardous and severe-duty environments. It features a corrosion-resistant heat-flowed epoxy housing with wall mounting and a 3/4-inch conduit entry for secure installation. The vibrating horn is intended for facilities such as petroleum plants, gas plants, mines, grain elevators, paper mills, textile plants, flour mills, and tankers where dependable audible warning is essential. Its rugged enclosure is designed to withstand harsh environmental conditions while providing consistent signaling performance in hazardous locations.
Key Features:
- High-Decibel Output: Produces up to 110 dB at 1 meter for clear audible warning.
- 24 VAC Operation: Designed for 24 VAC, 50/60 Hz industrial control systems.
- Heavy-Duty Vibrating Horn: Provides reliable mechanical audible signaling.
- Hazardous Location Application: Suitable for industrial hazardous environments requiring robust warning devices.
- NEMA 4X Enclosure: Protects against water, corrosion, dust, and harsh weather conditions.
- Corrosion-Resistant Housing: Constructed with heat-flowed epoxy for long service life.
- Flexible Installation: Wall-mounted design with 3/4-inch conduit tapping for convenient wiring.
- UL Listed: Certified to meet recognized industrial safety standards.
The 878EX-G5 delivers the reliability and precision required for hazardous-area audible warning, industrial safety notification, and emergency signaling applications.