EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit
EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit
EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit
    EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit
EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit

EL3202 | Beckhoff EtherCAT Terminal, 2-Channel RTD Temperature Input, 16-bit

Part #: EL3202 Manufactured by: Beckhoff
Regular price
$289.00
Sale price
$289.00
Regular price
4 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
Beckhoff El3202 2 Channel Analog Input Pt100 Module
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: EL3202
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Beckhoff
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: EL3202

Description / Specifications

Description

The Beckhoff EL3202 is a 2-channel analog input EtherCAT terminal designed for precise temperature measurement using RTD sensors such as Pt100, Pt200, Pt500, Pt1000, and Ni series sensors. With 16-bit measurement resolution and support for both 2-wire and 3-wire connections, it provides highly accurate temperature acquisition for industrial automation and process monitoring applications.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Manufacturer Beckhoff
Part Number EL3202
Category PLCs / Machine Control
Subcategory EtherCAT Analog Input Terminal
Number of Inputs 2 RTD Inputs
Supported Sensor Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, KTY, Resistive sensors (10 Ω…1.2 kΩ / 4 kΩ)
Connection Method 2-wire or 3-wire (default: 3-wire)
Resolution 16-bit (0.1 °C per digit)
Temperature Range Pt: -200…+850 °C; Ni: -60…+250 °C
Measuring Current < 0.5 mA (load dependent)
Conversion Time 85 ms default; configurable 2…800 ms
Input Filter Limit Frequency typ. 1 kHz
Measuring Error < ±0.5 °C (Pt sensors)
Electrical Isolation 500 V (E-bus / signal voltage)
E-bus Current Consumption typ. 190 mA
Operating Temperature -25…+60 °C
Storage Temperature -40…+85 °C
Relative Humidity 95% (no condensation)

  

 

Information About EL3202

The EL3202 is part of the Beckhoff EtherCAT Terminal system and is specifically designed for high-accuracy RTD temperature measurement. It supports direct connection of two resistive temperature sensors, and the terminal can output either raw resistance values or converted temperature readings based on selectable sensor characteristics. Configured through Beckhoff TwinCAT software, the EL3202 allows users to choose the desired temperature conversion curve (Pt, Ni, KTY, etc.) and measurement mode. It supports both 2-wire and 3-wire sensor compensation, with 3-wire being the preferred method for reducing lead-wire resistance errors.

Key Features:

  • 2 RTD Measurement Channels supporting Pt100, Pt1000, Ni100, Ni1000, and various resistive sensors.
  • High Accuracy: 16-bit resolution with < ±0.5 °C error for Pt sensors.
  • Flexible Connection: Supports 2-wire and 3-wire RTD wiring.
  • Configurable Conversion: Outputs temperature or raw resistance with selectable curves.
  • Fast and Adjustable Sampling: Conversion times from 2 ms to 800 ms.
  • Industrial Reliability: Electrical isolation and robust EMC performance.
  • Easy Integration: Seamlessly connects to TwinCAT and EtherCAT automation systems.

The EL3202 delivers the precision, flexibility, and reliability required for accurate temperature acquisition in distributed EtherCAT-based automation systems.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description

The Beckhoff EL3202 is a 2-channel analog input EtherCAT terminal designed for precise temperature measurement using RTD sensors such as Pt100, Pt200, Pt500, Pt1000, and Ni series sensors. With 16-bit measurement resolution and support for both 2-wire and 3-wire connections, it provides highly accurate temperature acquisition for industrial automation and process monitoring applications.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Manufacturer Beckhoff
Part Number EL3202
Category PLCs / Machine Control
Subcategory EtherCAT Analog Input Terminal
Number of Inputs 2 RTD Inputs
Supported Sensor Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, KTY, Resistive sensors (10 Ω…1.2 kΩ / 4 kΩ)
Connection Method 2-wire or 3-wire (default: 3-wire)
Resolution 16-bit (0.1 °C per digit)
Temperature Range Pt: -200…+850 °C; Ni: -60…+250 °C
Measuring Current < 0.5 mA (load dependent)
Conversion Time 85 ms default; configurable 2…800 ms
Input Filter Limit Frequency typ. 1 kHz
Measuring Error < ±0.5 °C (Pt sensors)
Electrical Isolation 500 V (E-bus / signal voltage)
E-bus Current Consumption typ. 190 mA
Operating Temperature -25…+60 °C
Storage Temperature -40…+85 °C
Relative Humidity 95% (no condensation)

  

 

Information About EL3202

The EL3202 is part of the Beckhoff EtherCAT Terminal system and is specifically designed for high-accuracy RTD temperature measurement. It supports direct connection of two resistive temperature sensors, and the terminal can output either raw resistance values or converted temperature readings based on selectable sensor characteristics. Configured through Beckhoff TwinCAT software, the EL3202 allows users to choose the desired temperature conversion curve (Pt, Ni, KTY, etc.) and measurement mode. It supports both 2-wire and 3-wire sensor compensation, with 3-wire being the preferred method for reducing lead-wire resistance errors.

Key Features:

  • 2 RTD Measurement Channels supporting Pt100, Pt1000, Ni100, Ni1000, and various resistive sensors.
  • High Accuracy: 16-bit resolution with < ±0.5 °C error for Pt sensors.
  • Flexible Connection: Supports 2-wire and 3-wire RTD wiring.
  • Configurable Conversion: Outputs temperature or raw resistance with selectable curves.
  • Fast and Adjustable Sampling: Conversion times from 2 ms to 800 ms.
  • Industrial Reliability: Electrical isolation and robust EMC performance.
  • Easy Integration: Seamlessly connects to TwinCAT and EtherCAT automation systems.

The EL3202 delivers the precision, flexibility, and reliability required for accurate temperature acquisition in distributed EtherCAT-based automation systems.

Check Out These Related Products