Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems
Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems
Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems
    Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems
Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems

Emerson White-Rodgers 50A67-476-01 Integrated Furnace Control Board for Trane and American Standard Systems

Part #: 50A67-476-01 Manufactured by: Emerson
Regular price
$499.00
Sale price
$499.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The 50A67-476-01 is an Emerson White-Rodgers integrated furnace control board used in compatible Trane and American Standa...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 8:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: 50A67-476-01
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro BBB Business Review
IQElectro is Not an authorized distributor for Emerson
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: 50A67-476-01

Description / Specifications

Description

The Emerson White-Rodgers 50A67-476-01 is an integrated furnace control board designed to manage ignition sequencing, burner operation, blower control, and safety monitoring in compatible gas furnace systems. It coordinates signals from the thermostat, flame sensor, and safety switches to control the furnace operating cycle. The board is associated with Trane and American Standard furnace applications.



Technical Specifications

Condition New/Never Used Surplus
Brand Emerson / White-Rodgers
Category HVAC Equipment
Part Number 50A67-476-01
Subcategory Furnace Control Boards
Product Type Integrated Furnace Control Board
Application Gas Furnace Control
System Type Single-Stage Furnace Applications
Control Functions Ignition, flame monitoring, blower operation, safety monitoring
Compatible Equipment Brands Trane / American Standard
Manufacturer Cross-References CNT03076; CNT5164; D341213P01; L46-846
Ignition System Compatibility Confirm original ignitor voltage and furnace configuration
Replacement Considerations Some universal replacement controls require a 120 V ignitor upgrade
Manufacturer Emerson Electric Co.
Resolution at 4–20 mA 4 µA per count
Resolution at 0–20 mA 5 µA per count
External Supply Voltage 20–30 VDC
Backplane Current Consumption 120 mA at 5 VDC
External Supply Current Consumption 65 mA at 24 VDC, plus current-loop loads
Isolation Optical field-to-backplane isolation; 250 VAC continuous, 1500 VAC for 1 minute
Low-Alarm Monitoring Available on all input ranges
Open-Wire Detection Supported in enhanced 4–20 mA mode
Status Indicators Module OK and User Supply LEDs
Installation Any I/O slot in a compatible RX3i system
Revision DB
Weight 1.5 lb

 

 

Information About 50A67-476-01

The 50A67-476-01 belongs to the White-Rodgers family of integrated furnace control boards manufactured by Emerson. It is identified in manufacturer cross-reference documentation as an OEM control number for compatible single-stage furnace applications. The board manages ignition and heating-cycle functions while monitoring safety inputs and controlling connected furnace components. Its exact compatibility depends on the furnace model, original ignition system, and wiring configuration.

Key Features:

  • Integrated Furnace Control: Coordinates the main electrical control functions of a compatible gas furnace.

  • Ignition Sequence Management: Controls the timing and operation of the furnace ignition cycle.

  • Flame Monitoring: Works with the flame-sensing circuit to monitor burner operation.

  • Blower Control: Coordinates blower operation during heating cycles.

  • Safety Monitoring: Monitors connected safety switches and furnace operating conditions.

  • OEM Cross-Reference: Identified in White-Rodgers and Trane-related replacement documentation.

  • Single-Stage Applications: Associated with compatible single-stage furnace control systems.

  • Replacement Compatibility: Cross-referenced with several Trane and American Standard control-board numbers.

The 50A67-476-01 delivers the control functionality required for furnace ignition management, heating-cycle operation, and equipment safety monitoring.

      Get fast quote and compatibility check
      Compatibility check available   ·   Alternative parts suggested
      Get a response to your request within 5 minutes
      Talk to a real industrial automation specialist.
      We verify compatibility, suggest alternatives, and provide fast quotes.
      Something went wrong, please try again
      Form image
      Arty A.
      Senior Sales Manager
      Daniel S.
      Parts Specialist
      Request successfully sent!
      Estimated response time: 1 to 5 minutes.
      Description / Specifications

      Description

      The Emerson White-Rodgers 50A67-476-01 is an integrated furnace control board designed to manage ignition sequencing, burner operation, blower control, and safety monitoring in compatible gas furnace systems. It coordinates signals from the thermostat, flame sensor, and safety switches to control the furnace operating cycle. The board is associated with Trane and American Standard furnace applications.



      Technical Specifications

      Condition New/Never Used Surplus
      Brand Emerson / White-Rodgers
      Category HVAC Equipment
      Part Number 50A67-476-01
      Subcategory Furnace Control Boards
      Product Type Integrated Furnace Control Board
      Application Gas Furnace Control
      System Type Single-Stage Furnace Applications
      Control Functions Ignition, flame monitoring, blower operation, safety monitoring
      Compatible Equipment Brands Trane / American Standard
      Manufacturer Cross-References CNT03076; CNT5164; D341213P01; L46-846
      Ignition System Compatibility Confirm original ignitor voltage and furnace configuration
      Replacement Considerations Some universal replacement controls require a 120 V ignitor upgrade
      Manufacturer Emerson Electric Co.
      Resolution at 4–20 mA 4 µA per count
      Resolution at 0–20 mA 5 µA per count
      External Supply Voltage 20–30 VDC
      Backplane Current Consumption 120 mA at 5 VDC
      External Supply Current Consumption 65 mA at 24 VDC, plus current-loop loads
      Isolation Optical field-to-backplane isolation; 250 VAC continuous, 1500 VAC for 1 minute
      Low-Alarm Monitoring Available on all input ranges
      Open-Wire Detection Supported in enhanced 4–20 mA mode
      Status Indicators Module OK and User Supply LEDs
      Installation Any I/O slot in a compatible RX3i system
      Revision DB
      Weight 1.5 lb

       

       

      Information About 50A67-476-01

      The 50A67-476-01 belongs to the White-Rodgers family of integrated furnace control boards manufactured by Emerson. It is identified in manufacturer cross-reference documentation as an OEM control number for compatible single-stage furnace applications. The board manages ignition and heating-cycle functions while monitoring safety inputs and controlling connected furnace components. Its exact compatibility depends on the furnace model, original ignition system, and wiring configuration.

      Key Features:

      • Integrated Furnace Control: Coordinates the main electrical control functions of a compatible gas furnace.

      • Ignition Sequence Management: Controls the timing and operation of the furnace ignition cycle.

      • Flame Monitoring: Works with the flame-sensing circuit to monitor burner operation.

      • Blower Control: Coordinates blower operation during heating cycles.

      • Safety Monitoring: Monitors connected safety switches and furnace operating conditions.

      • OEM Cross-Reference: Identified in White-Rodgers and Trane-related replacement documentation.

      • Single-Stage Applications: Associated with compatible single-stage furnace control systems.

      • Replacement Compatibility: Cross-referenced with several Trane and American Standard control-board numbers.

      The 50A67-476-01 delivers the control functionality required for furnace ignition management, heating-cycle operation, and equipment safety monitoring.