Endress+Hauser CPS11D-7AA21 Memosens Digital pH Electrode with 120 mm Shaft
- Regular price
- $865.00
- Sale price
- $865.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: CPS11D-7AA21
Description
The Endress+Hauser CPS11D-7AA21 is a digital combination pH electrode with Memosens functionality for standard process measurements. It measures from pH 1 to 12 and combines a 120 mm shaft, PTFE ring diaphragm, and integrated temperature sensor.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Endress+Hauser |
| Category | Sensors & Switches |
| Part Number | CPS11D-7AA21 |
| Subcategory | PH Electrode |
| Product Type | Digital combination pH electrode |
| Version | Basic |
| Application | Standard process |
| Measurement Range | pH 1–12 |
| Process Temperature Range | −15 °C to +80 °C |
| Maximum Process Pressure | 6 bar |
| Shaft Length | 120 mm |
| Diaphragm | PTFE ring junction |
| Reference System | Gel |
| Minimum Medium Conductivity | 50 µS/cm |
| Temperature Sensor | Integrated NTC30K |
| Signal Transmission | Digital, Memosens |
| Connection Head | Memosens inductive plug-in head |
| Process Mounting Thread | PG 13.5 |
| Area Classification | Non-hazardous area |
| Weight | 0.99 lbs |
Information About CPS11D-7AA21
The CPS11D-7AA21 is a basic-version electrode from the Endress+Hauser CPS11D range. Its gel reference system and PTFE diaphragm provide the electrochemical reference connection to the process medium. The Memosens plug-in head transfers measurement data digitally through an inductive connection to compatible measuring equipment. This configuration is intended for non-hazardous areas and process media with a minimum conductivity of 50 µS/cm.
Key Features:
- Defined pH Range: Measures process conditions between pH 1 and pH 12.
- Memosens Interface: Provides inductive digital signal transmission to compatible measurement systems.
- PTFE Ring Diaphragm: Uses a large, dirt-repellent junction to resist contamination.
- Gel Reference System: Incorporates a gel-filled reference for standard process applications.
- Integrated Temperature Sensing: Includes an NTC30K sensor for measuring temperature alongside pH.
- Standard Shaft Length: Provides a 120 mm insertion shaft for compatible electrode assemblies.
- Process Operating Limits: Supports temperatures from −15 °C to +80 °C and pressure up to 6 bar.
- Non-Hazardous Configuration: Specifies use in installations outside hazardous areas.
The CPS11D-7AA21 delivers the reliability and precision required for digital pH monitoring in standard industrial process systems.
Description
The Endress+Hauser CPS11D-7AA21 is a digital combination pH electrode with Memosens functionality for standard process measurements. It measures from pH 1 to 12 and combines a 120 mm shaft, PTFE ring diaphragm, and integrated temperature sensor.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Endress+Hauser |
| Category | Sensors & Switches |
| Part Number | CPS11D-7AA21 |
| Subcategory | PH Electrode |
| Product Type | Digital combination pH electrode |
| Version | Basic |
| Application | Standard process |
| Measurement Range | pH 1–12 |
| Process Temperature Range | −15 °C to +80 °C |
| Maximum Process Pressure | 6 bar |
| Shaft Length | 120 mm |
| Diaphragm | PTFE ring junction |
| Reference System | Gel |
| Minimum Medium Conductivity | 50 µS/cm |
| Temperature Sensor | Integrated NTC30K |
| Signal Transmission | Digital, Memosens |
| Connection Head | Memosens inductive plug-in head |
| Process Mounting Thread | PG 13.5 |
| Area Classification | Non-hazardous area |
| Weight | 0.99 lbs |
Information About CPS11D-7AA21
The CPS11D-7AA21 is a basic-version electrode from the Endress+Hauser CPS11D range. Its gel reference system and PTFE diaphragm provide the electrochemical reference connection to the process medium. The Memosens plug-in head transfers measurement data digitally through an inductive connection to compatible measuring equipment. This configuration is intended for non-hazardous areas and process media with a minimum conductivity of 50 µS/cm.
Key Features:
- Defined pH Range: Measures process conditions between pH 1 and pH 12.
- Memosens Interface: Provides inductive digital signal transmission to compatible measurement systems.
- PTFE Ring Diaphragm: Uses a large, dirt-repellent junction to resist contamination.
- Gel Reference System: Incorporates a gel-filled reference for standard process applications.
- Integrated Temperature Sensing: Includes an NTC30K sensor for measuring temperature alongside pH.
- Standard Shaft Length: Provides a 120 mm insertion shaft for compatible electrode assemblies.
- Process Operating Limits: Supports temperatures from −15 °C to +80 °C and pressure up to 6 bar.
- Non-Hazardous Configuration: Specifies use in installations outside hazardous areas.
The CPS11D-7AA21 delivers the reliability and precision required for digital pH monitoring in standard industrial process systems.