Faraday MPC-DACT Digital Alarm Communicator Transmitter Module for MPC Fire Panels
- Regular price
- $2,199.00
- Sale price
- $2,199.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: MPC-DACT
Description
The Faraday MPC-DACT is a Digital Alarm Communicator Transmitter module designed to provide communication between compatible fire alarm control panels and central or remote monitoring stations. It transmits alarm and system status information through telephone lines, supporting remote supervision of MPC-6000 and MPC-7000 fire alarm systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Faraday |
| Category | Fire Safety |
| Part Number | MPC-DACT |
| Subcategory | Fire Alarm Communicators |
| Product Type | Digital Alarm Communicator Transmitter (DACT) Module |
| Compatible Systems | MPC-6000, MPC-7000, RND-2 |
| Primary Function | Transmits fire alarm system signals to central or remote monitoring stations |
| Telephone Lines | 2 |
| Reported Event Types | Alarm, Supervisory, Trouble, Reset, Trouble Restore |
| Communication Protocols | SIA DCS 8, SIA DCS 20, Ademco Contact ID, 3/1 1400 Hz, 3/1 2300 Hz, 4/2 1400 Hz, 4/2 2300 Hz |
| Serial Information | Supports transmission of serial event information, including event addresses |
| Automatic Test | 24-hour automatic communication test available |
| Mounting Location | Directly on main termination board within compatible MPC enclosure |
| Programming | Integrated through CIS-4 system configuration |
| Agency Listings | UL 864 9th Edition Listed; NFPA 72 compliant monitoring application; FM Approved |
| Testing | Factory validated |
| Weight | 0.25 lb. |
Information About MPC-DACT
The MPC-DACT is a Faraday Digital Alarm Communicator Transmitter designed for installation directly within compatible MPC-6000 or MPC-7000 control panel enclosures. It mounts on the main termination board without requiring an external enclosure, separate wiring between the panel and dialer, or an external programmer. The module supports two telephone lines and two separate monitoring accounts, allowing configured transmission of alarm, supervisory, trouble, reset, and trouble restore events. Communication and account settings are programmed as part of the CIS-4 system configuration.
Key Features:
- Dual Telephone Lines: Supports two separate telephone-line connections for monitoring communication.
- Two Monitoring Accounts: Allows configuration of two independent central or remote monitoring accounts.
- Event Transmission: Transmits alarm, supervisory, trouble, reset, and trouble restore information.
- Serial Information Support: Can transmit serial event information, including event addresses, to the monitoring station.
- Multiple Protocols: Supports seven standard communication formats for compatibility with monitoring receivers.
- Direct Panel Mounting: Installs directly on the main termination board within compatible MPC panel enclosures.
- Automatic Testing: Supports the automatic 24-hour communication test required for applicable NFPA 72 monitoring configurations.
- Integrated Programming: Account and dialing information are configured through the CIS-4 system configuration without a separate dialer programmer.
The MPC-DACT delivers the reliability and precision required for transmitting fire alarm system events to central and remote monitoring stations.
Description
The Faraday MPC-DACT is a Digital Alarm Communicator Transmitter module designed to provide communication between compatible fire alarm control panels and central or remote monitoring stations. It transmits alarm and system status information through telephone lines, supporting remote supervision of MPC-6000 and MPC-7000 fire alarm systems.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Faraday |
| Category | Fire Safety |
| Part Number | MPC-DACT |
| Subcategory | Fire Alarm Communicators |
| Product Type | Digital Alarm Communicator Transmitter (DACT) Module |
| Compatible Systems | MPC-6000, MPC-7000, RND-2 |
| Primary Function | Transmits fire alarm system signals to central or remote monitoring stations |
| Telephone Lines | 2 |
| Reported Event Types | Alarm, Supervisory, Trouble, Reset, Trouble Restore |
| Communication Protocols | SIA DCS 8, SIA DCS 20, Ademco Contact ID, 3/1 1400 Hz, 3/1 2300 Hz, 4/2 1400 Hz, 4/2 2300 Hz |
| Serial Information | Supports transmission of serial event information, including event addresses |
| Automatic Test | 24-hour automatic communication test available |
| Mounting Location | Directly on main termination board within compatible MPC enclosure |
| Programming | Integrated through CIS-4 system configuration |
| Agency Listings | UL 864 9th Edition Listed; NFPA 72 compliant monitoring application; FM Approved |
| Testing | Factory validated |
| Weight | 0.25 lb. |
Information About MPC-DACT
The MPC-DACT is a Faraday Digital Alarm Communicator Transmitter designed for installation directly within compatible MPC-6000 or MPC-7000 control panel enclosures. It mounts on the main termination board without requiring an external enclosure, separate wiring between the panel and dialer, or an external programmer. The module supports two telephone lines and two separate monitoring accounts, allowing configured transmission of alarm, supervisory, trouble, reset, and trouble restore events. Communication and account settings are programmed as part of the CIS-4 system configuration.
Key Features:
- Dual Telephone Lines: Supports two separate telephone-line connections for monitoring communication.
- Two Monitoring Accounts: Allows configuration of two independent central or remote monitoring accounts.
- Event Transmission: Transmits alarm, supervisory, trouble, reset, and trouble restore information.
- Serial Information Support: Can transmit serial event information, including event addresses, to the monitoring station.
- Multiple Protocols: Supports seven standard communication formats for compatibility with monitoring receivers.
- Direct Panel Mounting: Installs directly on the main termination board within compatible MPC panel enclosures.
- Automatic Testing: Supports the automatic 24-hour communication test required for applicable NFPA 72 monitoring configurations.
- Integrated Programming: Account and dialing information are configured through the CIS-4 system configuration without a separate dialer programmer.
The MPC-DACT delivers the reliability and precision required for transmitting fire alarm system events to central and remote monitoring stations.