Product Description P/N: MAUV1
Description
The Fireye MAUV1 is an M-Series II ultraviolet amplifier module designed to process flame signals from compatible UV scanners in burner safeguard systems. It provides a 2–4 second Flame Failure Response Time (FFRT), enabling the associated control to respond to loss of detected flame during burner operation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Fireye |
| Category | Burner Controls |
| Part Number | MAUV1 |
| Subcategory | Flame Amplifier Modules |
| Product Type | Ultra-Violet Amplifier Module |
| Series | M-Series II |
| Detection Technology | Ultraviolet (UV) |
| Flame Failure Response Time | 2–4 seconds |
| Control Compatibility | Fireye Modular M-Series II |
| Compatible Scanner | UV1A |
| Compatible Scanner | UV2 |
| Compatible Scanner | UV8A |
| Compatible Scanner | 45UV3-1050 |
| Installation Type | Plug-In Module |
| Diagnostic Feature | Flame Signal Test Jacks |
| Application | Burner Flame Safeguard and Supervision |
| Weight | 2 lb |
Information About MAUV1
The MAUV1 is a plug-in ultraviolet flame amplifier developed for the Fireye Modular M-Series II control platform. It is compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 ultraviolet flame scanners and is not intended for self-check scanner applications. The amplifier processes scanner signals while the installed programmer module determines operating characteristics such as purge timing, relight behavior, and burner sequencing. Integrated test jacks allow flame-signal measurement during operation for system setup, diagnostics, and maintenance.
Key Features:
- UV Flame Amplification: Processes ultraviolet flame signals from compatible Fireye scanners.
- 2–4 Second FFRT: Provides a Flame Failure Response Time of approximately 2 to 4 seconds.
- M-Series II Compatibility: Designed specifically for Fireye Modular M-Series II flame safeguard controls.
- Multiple Scanner Support: Compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 UV scanners.
- Plug-In Construction: Uses a modular plug-in design for integration with the appropriate M-Series II chassis.
- Flame Signal Test Jacks: Provides test points for measuring flame signal strength during burner operation.
- Standard UV Operation: Intended for standard ultraviolet flame scanners rather than self-check UV scanners.
- Burner Safeguard Application: Supports flame-presence supervision in automatically fired burner systems.
The MAUV1 delivers the reliability and precision required for ultraviolet flame detection and burner safeguard control applications.
Description
The Fireye MAUV1 is an M-Series II ultraviolet amplifier module designed to process flame signals from compatible UV scanners in burner safeguard systems. It provides a 2–4 second Flame Failure Response Time (FFRT), enabling the associated control to respond to loss of detected flame during burner operation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Fireye |
| Category | Burner Controls |
| Part Number | MAUV1 |
| Subcategory | Flame Amplifier Modules |
| Product Type | Ultra-Violet Amplifier Module |
| Series | M-Series II |
| Detection Technology | Ultraviolet (UV) |
| Flame Failure Response Time | 2–4 seconds |
| Control Compatibility | Fireye Modular M-Series II |
| Compatible Scanner | UV1A |
| Compatible Scanner | UV2 |
| Compatible Scanner | UV8A |
| Compatible Scanner | 45UV3-1050 |
| Installation Type | Plug-In Module |
| Diagnostic Feature | Flame Signal Test Jacks |
| Application | Burner Flame Safeguard and Supervision |
| Weight | 2 lb |
Information About MAUV1
The MAUV1 is a plug-in ultraviolet flame amplifier developed for the Fireye Modular M-Series II control platform. It is compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 ultraviolet flame scanners and is not intended for self-check scanner applications. The amplifier processes scanner signals while the installed programmer module determines operating characteristics such as purge timing, relight behavior, and burner sequencing. Integrated test jacks allow flame-signal measurement during operation for system setup, diagnostics, and maintenance.
Key Features:
- UV Flame Amplification: Processes ultraviolet flame signals from compatible Fireye scanners.
- 2–4 Second FFRT: Provides a Flame Failure Response Time of approximately 2 to 4 seconds.
- M-Series II Compatibility: Designed specifically for Fireye Modular M-Series II flame safeguard controls.
- Multiple Scanner Support: Compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 UV scanners.
- Plug-In Construction: Uses a modular plug-in design for integration with the appropriate M-Series II chassis.
- Flame Signal Test Jacks: Provides test points for measuring flame signal strength during burner operation.
- Standard UV Operation: Intended for standard ultraviolet flame scanners rather than self-check UV scanners.
- Burner Safeguard Application: Supports flame-presence supervision in automatically fired burner systems.
The MAUV1 delivers the reliability and precision required for ultraviolet flame detection and burner safeguard control applications.