FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector
FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector
FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector
    FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector
FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector

FP-11 | Siemens Intelligent FirePrintTM Smoke/Heat Detector

Part #: FP-11 Manufactured by: Siemens
Regular price
$77.00
Sale price
$77.00
Regular price
10 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The Siemens FP-11 is a FirePrint™-enabled smoke and heat detector that integrates dual sensing technology with intelligent...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: FP-11
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Siemens
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: FP-11

Description / Specifications

Description 

The FP-11 is an intelligent smoke and heat detector featuring FirePrint™ technology, which delivers advanced sensing for a wide range of fire conditions. Engineered for compatibility with the Siemens MXL series fire alarm control panels, this 2-wire detector offers both early fire detection and high immunity to false alarms.

 

 

Technical Specifications 

Condition

New/Never Used Surplus

Brand Siemens

Category

Fire Safety

Part Number

FP-11

Subcatecory
Fire Alarm Systems

Detection Type Smoke/Heat (Intelligent FirePrint™)
Operating Voltage 16–27V DC
Supervisory Current 110μA max
Alarm Current 33–50mA
Alarm Temperature 135°F (57°C)
Operating Temperature Range 32°F to 100°F (0°C to 38°C)
Humidity Range Up to 93% RH (non-condensing)
Weight 0.11 kg

  

 

Information About FP-11

The FP-11 is a part of Siemens’ MXL-compatible FirePrint™ detection family, combining multiple sensing elements and sophisticated algorithms to accurately distinguish between real fire threats and nuisance sources. Powered by 16–27V DC, the detector operates reliably across various environmental conditions.

It is engineered to detect both smoke and heat, with a preset alarm threshold of 135°F (57°C). It operates efficiently in environments with humidity up to 93% (non-condensing) and without being affected by atmospheric pressure changes.

Key Features:

  • Advanced FirePrint™ Technology: Enhances fire detection while minimizing nuisance alarms through intelligent analysis of smoke and thermal signatures.

  • Dual Sensing Capability: Combines smoke and heat detection in one device for greater coverage and faster response time.

  • Wide Operating Range: Functions between 32°F to 100°F with high humidity tolerance (up to 93%).

  • Energy-Efficient Operation: Consumes only 110μA in supervisory mode and 33–50mA in alarm state.

  • System Compatibility: Fully compatible with Siemens MXL family fire alarm control panels via 2-wire interface.

  • Fixed Heat Detection Threshold: Triggers heat alarm at 135°F (57°C), providing secondary detection layer.

The FP-11 intelligently responds to genuine fire conditions while reducing false alarms, offering reliable performance for commercial fire safety systems.

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The FP-11 is an intelligent smoke and heat detector featuring FirePrint™ technology, which delivers advanced sensing for a wide range of fire conditions. Engineered for compatibility with the Siemens MXL series fire alarm control panels, this 2-wire detector offers both early fire detection and high immunity to false alarms.

 

 

Technical Specifications 

Condition

New/Never Used Surplus

Brand Siemens

Category

Fire Safety

Part Number

FP-11

Subcatecory
Fire Alarm Systems

Detection Type Smoke/Heat (Intelligent FirePrint™)
Operating Voltage 16–27V DC
Supervisory Current 110μA max
Alarm Current 33–50mA
Alarm Temperature 135°F (57°C)
Operating Temperature Range 32°F to 100°F (0°C to 38°C)
Humidity Range Up to 93% RH (non-condensing)
Weight 0.11 kg

  

 

Information About FP-11

The FP-11 is a part of Siemens’ MXL-compatible FirePrint™ detection family, combining multiple sensing elements and sophisticated algorithms to accurately distinguish between real fire threats and nuisance sources. Powered by 16–27V DC, the detector operates reliably across various environmental conditions.

It is engineered to detect both smoke and heat, with a preset alarm threshold of 135°F (57°C). It operates efficiently in environments with humidity up to 93% (non-condensing) and without being affected by atmospheric pressure changes.

Key Features:

  • Advanced FirePrint™ Technology: Enhances fire detection while minimizing nuisance alarms through intelligent analysis of smoke and thermal signatures.

  • Dual Sensing Capability: Combines smoke and heat detection in one device for greater coverage and faster response time.

  • Wide Operating Range: Functions between 32°F to 100°F with high humidity tolerance (up to 93%).

  • Energy-Efficient Operation: Consumes only 110μA in supervisory mode and 33–50mA in alarm state.

  • System Compatibility: Fully compatible with Siemens MXL family fire alarm control panels via 2-wire interface.

  • Fixed Heat Detection Threshold: Triggers heat alarm at 135°F (57°C), providing secondary detection layer.

The FP-11 intelligently responds to genuine fire conditions while reducing false alarms, offering reliable performance for commercial fire safety systems.