FRS-R-100 | Eaton Bussmann Class RK5 100A Time-Delay Fuse, Blade End
- Regular price
- $62.00
- Sale price
- $62.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: FRS-R-100
Description
The Eaton Bussmann FRS-R-100 is a Class RK5 dual-element time-delay fuse rated at 100 amps. It provides overcurrent protection for AC and DC systems with high interrupting capacity. This fuse is designed for blade-end mounting and non-indicating operation in industrial and commercial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton Bussmann |
| Category | Panel Accessories |
| Part Number | FRS-R-100 |
| Subcategory | Fuse |
| Fuse Class | RK5 |
| Amperage Rating | 100 A |
| Voltage Rating | 600 VAC, 300 VDC |
| Interrupt Rating (AC) | 200 kAIC at 600 VAC |
| Interrupt Rating (DC) | 20 kAIC at 300 VDC |
| Response Time | 10 seconds at 500% overload |
| Number of Elements | Dual |
| Terminal Type | Blade end × blade end |
| Indication Type | Non-indicating |
| Length | 5 in |
| Height | 0.81 in |
| Width | 0.81 in |
| Compliance | CE Marked |
Information About RS-R-100
The FRS-R-100 is a Class RK5 fuse within the Eaton Bussmann series of circuit protection devices. It is constructed as a dual-element, time-delay fuse to accommodate temporary overloads while maintaining protection against sustained overcurrent conditions. The fuse features blade-end connections for secure installation in compatible fuse holders and disconnects. It is typically used in motor circuits, feeders, and branch circuits where controlled time-delay response and high interrupt ratings are required.
Key Features:
- Class RK5 fuse design: Provides standardized protection for industrial circuits.
- Dual-element construction: Allows time-delay response to motor starting currents.
- Time-delay characteristic: Rated at 10 seconds at 500% overload.
- High interrupting capacity: Supports both AC and DC fault conditions.
- Blade end terminals: Ensures secure and consistent electrical connections.
- Non-indicating type: Designed for applications not requiring visual status indication.
- Compact fuse body: Suitable for dense panel and disconnect installations.
The FRS-R-100 delivers the reliability and precision required for overcurrent protection in motor, feeder, and industrial power distribution systems.
Description
The Eaton Bussmann FRS-R-100 is a Class RK5 dual-element time-delay fuse rated at 100 amps. It provides overcurrent protection for AC and DC systems with high interrupting capacity. This fuse is designed for blade-end mounting and non-indicating operation in industrial and commercial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton Bussmann |
| Category | Panel Accessories |
| Part Number | FRS-R-100 |
| Subcategory | Fuse |
| Fuse Class | RK5 |
| Amperage Rating | 100 A |
| Voltage Rating | 600 VAC, 300 VDC |
| Interrupt Rating (AC) | 200 kAIC at 600 VAC |
| Interrupt Rating (DC) | 20 kAIC at 300 VDC |
| Response Time | 10 seconds at 500% overload |
| Number of Elements | Dual |
| Terminal Type | Blade end × blade end |
| Indication Type | Non-indicating |
| Length | 5 in |
| Height | 0.81 in |
| Width | 0.81 in |
| Compliance | CE Marked |
Information About RS-R-100
The FRS-R-100 is a Class RK5 fuse within the Eaton Bussmann series of circuit protection devices. It is constructed as a dual-element, time-delay fuse to accommodate temporary overloads while maintaining protection against sustained overcurrent conditions. The fuse features blade-end connections for secure installation in compatible fuse holders and disconnects. It is typically used in motor circuits, feeders, and branch circuits where controlled time-delay response and high interrupt ratings are required.
Key Features:
- Class RK5 fuse design: Provides standardized protection for industrial circuits.
- Dual-element construction: Allows time-delay response to motor starting currents.
- Time-delay characteristic: Rated at 10 seconds at 500% overload.
- High interrupting capacity: Supports both AC and DC fault conditions.
- Blade end terminals: Ensures secure and consistent electrical connections.
- Non-indicating type: Designed for applications not requiring visual status indication.
- Compact fuse body: Suitable for dense panel and disconnect installations.
The FRS-R-100 delivers the reliability and precision required for overcurrent protection in motor, feeder, and industrial power distribution systems.