Part #: FX-5R Manufactured by: Edwards Signaling
Regular price
$675.00
Sale price
$675.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The FX-5R is a conventional 5-zone fire alarm control panel from Edwards Signaling, offering a balance of durability, prog...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 8:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: FX-5R
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro BBB Business Review
IQElectro is Not an authorized distributor for Edwards Signaling
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: FX-5R

Description / Specifications

Description 

The Edwards Signaling FX-5R is a 5-zone conventional fire alarm control panel designed for reliable fire detection and notification in commercial and institutional applications. This steel-constructed unit supports Class B IDCs and NACs, with the option to convert to Class A circuits, ensuring flexible installation and dependable operation. With integrated features such as CleanMe and drift compensation, the FX-5R reduces false alarms and extends detector life.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Edwards Signaling
Category Fire Safety
Part Number FX-5R
Subcategory Fire Alarm Control
Type 5-Zone Conventional Fire Alarm Control Panel
Series FX Series
Circuit Inputs 5 IDCs (Class B, convertible to Class A)
Circuit Outputs 2 NACs (Class B, convertible to Class A)
NAC Power Capacity 3.5 A per panel, 2 A per circuit
Input Power 120 VAC
Output Power 24 VDC
Display Type LCD
Temperature Rating 32°F to 120°F (0°C to 49°C)
Cabinet Material Steel
Color Red
Dimensions 19.5 in H × 14.25 in W × 3.75 in D
Certifications ANSI/UL 864 9th Edition, CSFM Approved, FDNY Approved
Mounting Wall mount
Weight 24.00 lbs

 

 

Information About FX-5R

The FX-5R is part of the Edwards FX Series, which includes conventional fire alarm panels built to meet ANSI/UL 864 9th Edition standards. It is equipped with five initiating device circuits and two notification appliance circuits, both convertible to Class A configurations for added system resilience. The panel provides 3.5A of NAC power and includes features such as zone-level programmability, annunciation, and synchronization with compatible notification appliances. Its rugged steel housing, LCD display, and compatibility with serial annunciator and relay modules make it suitable for a wide range of fire protection systems in mid-sized facilities.

Key Features:

  • Five Initiating Device Circuits: Supports up to five Class B IDCs, convertible to Class A.
  • Two Notification Appliance Circuits: Each Class B, with option to convert to Class A for enhanced reliability.
  • 3.5A NAC Power Supply: Provides sufficient capacity for multiple notification appliances.
  • CleanMe and Drift Compensation: Maintains detector sensitivity and reduces nuisance alarms.
  • Programmable Operation: Allows zone and NAC customization directly from the front panel.
  • Integrated DACT Option: Enables upload/download capability and PC programming.
  • Steel Cabinet Construction: Ensures durability and long service life in demanding environments.
  • UL and CSFM Approved: Meets industry safety standards for fire alarm systems.

The FX-5R delivers the reliability and flexibility required for professional fire detection and alarm installations.

Get fast quote and compatibility check
Compatibility check available   ·   Alternative parts suggested
Get a response to your request within 5 minutes
Talk to a real industrial automation specialist.
We verify compatibility, suggest alternatives, and provide fast quotes.
Something went wrong, please try again
Form image
Arty A.
Senior Sales Manager
Daniel S.
Parts Specialist
Request successfully sent!
Estimated response time: 1 to 5 minutes.
Description / Specifications

Description 

The Edwards Signaling FX-5R is a 5-zone conventional fire alarm control panel designed for reliable fire detection and notification in commercial and institutional applications. This steel-constructed unit supports Class B IDCs and NACs, with the option to convert to Class A circuits, ensuring flexible installation and dependable operation. With integrated features such as CleanMe and drift compensation, the FX-5R reduces false alarms and extends detector life.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Edwards Signaling
Category Fire Safety
Part Number FX-5R
Subcategory Fire Alarm Control
Type 5-Zone Conventional Fire Alarm Control Panel
Series FX Series
Circuit Inputs 5 IDCs (Class B, convertible to Class A)
Circuit Outputs 2 NACs (Class B, convertible to Class A)
NAC Power Capacity 3.5 A per panel, 2 A per circuit
Input Power 120 VAC
Output Power 24 VDC
Display Type LCD
Temperature Rating 32°F to 120°F (0°C to 49°C)
Cabinet Material Steel
Color Red
Dimensions 19.5 in H × 14.25 in W × 3.75 in D
Certifications ANSI/UL 864 9th Edition, CSFM Approved, FDNY Approved
Mounting Wall mount
Weight 24.00 lbs

 

 

Information About FX-5R

The FX-5R is part of the Edwards FX Series, which includes conventional fire alarm panels built to meet ANSI/UL 864 9th Edition standards. It is equipped with five initiating device circuits and two notification appliance circuits, both convertible to Class A configurations for added system resilience. The panel provides 3.5A of NAC power and includes features such as zone-level programmability, annunciation, and synchronization with compatible notification appliances. Its rugged steel housing, LCD display, and compatibility with serial annunciator and relay modules make it suitable for a wide range of fire protection systems in mid-sized facilities.

Key Features:

  • Five Initiating Device Circuits: Supports up to five Class B IDCs, convertible to Class A.
  • Two Notification Appliance Circuits: Each Class B, with option to convert to Class A for enhanced reliability.
  • 3.5A NAC Power Supply: Provides sufficient capacity for multiple notification appliances.
  • CleanMe and Drift Compensation: Maintains detector sensitivity and reduces nuisance alarms.
  • Programmable Operation: Allows zone and NAC customization directly from the front panel.
  • Integrated DACT Option: Enables upload/download capability and PC programming.
  • Steel Cabinet Construction: Ensures durability and long service life in demanding environments.
  • UL and CSFM Approved: Meets industry safety standards for fire alarm systems.

The FX-5R delivers the reliability and flexibility required for professional fire detection and alarm installations.