Gamewell-FCI ASD-IL Analog Addressable Ionization Smoke Detector
- Regular price
- $417.00
- Sale price
- $417.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: ASD-IL
Description
The Gamewell-FCI ASD-IL is an analog addressable ionization smoke detector designed to provide fast and reliable smoke detection for Gamewell-FCI fire alarm control systems. It uses advanced communication technology to improve data exchange speed between detectors and compatible analog addressable panels while maintaining low standby current operation. The detector is intended for commercial fire protection applications requiring early detection and dependable alarm reporting.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Gamewell-FCI |
| Category | Fire Alarm Systems |
| Part Number | ASD-IL |
| Subcategory | Ionization Smoke Detector |
| Product Type | Analog Addressable Ionization Smoke Detector |
| Detection Technology | Ionization smoke sensing |
| Communication Type | Analog addressable communication |
| Compatible Systems | Gamewell-FCI analog addressable fire alarm controls |
| Operating Voltage | 15–32 VDC |
| Standby Current | Low standby current operation |
| Communication Method | Group polling protocol |
| Test Method | External magnetic test switch |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Relative Humidity | 10% to 93% RH non-condensing |
| Housing Design | Low-profile detector body |
| Installation Type | Ceiling-mounted detector base installation |
| Application | Commercial fire detection systems |
| Signal Processing | Microprocessor-controlled detector communication |
| Weight | Approximately 0.35 lbs |
Information About ASD-IL
The ASD-IL is part of the Gamewell-FCI analog addressable smoke detector family, developed for integration with compatible fire alarm control panels using addressable communication protocols. The detector features a low-profile housing design, noise-resistant communication, and grouped polling technology that improves response speed during system events. It includes a built-in magnetic test switch for simplified functional testing and maintenance procedures. The ASD-IL is designed for indoor fire detection applications where stable ionization sensing and reliable panel communication are required.
Key Features:
- Ionization Smoke Detection: Provides fast response to combustion particles and smoke conditions using ionization sensing technology.
- Analog Addressable Communication: Allows individual detector identification and status monitoring through compatible Gamewell-FCI control panels.
- High-Speed Communication Protocol: Uses advanced polling technology to improve communication response compared with earlier detector designs.
- Group Polling Operation: Enables the control panel to quickly identify devices with changed conditions within a detector group.
- Low Standby Current: Reduces system power consumption during normal monitoring operation.
- Noise-Resistant Communication: Provides stable data transmission in electrically demanding environments.
- Low-Profile Housing: Features a compact design suitable for modern fire alarm installations.
- Magnetic Test Function: Includes an external magnet-activated functional test switch for maintenance checks.
- Wide Compatibility: Designed for use with compatible Gamewell-FCI analog addressable fire alarm systems.
- Supervised Operation: Provides continuous monitoring and status reporting to the connected fire alarm panel.
- Indoor Application Support: Suitable for commercial buildings and general fire detection installations.
- Simple Installation: Designed for straightforward mounting and integration with existing detector bases.
The ASD-IL delivers the reliability and precision required for analog addressable smoke detection and commercial fire alarm system protection.
Description
The Gamewell-FCI ASD-IL is an analog addressable ionization smoke detector designed to provide fast and reliable smoke detection for Gamewell-FCI fire alarm control systems. It uses advanced communication technology to improve data exchange speed between detectors and compatible analog addressable panels while maintaining low standby current operation. The detector is intended for commercial fire protection applications requiring early detection and dependable alarm reporting.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Gamewell-FCI |
| Category | Fire Alarm Systems |
| Part Number | ASD-IL |
| Subcategory | Ionization Smoke Detector |
| Product Type | Analog Addressable Ionization Smoke Detector |
| Detection Technology | Ionization smoke sensing |
| Communication Type | Analog addressable communication |
| Compatible Systems | Gamewell-FCI analog addressable fire alarm controls |
| Operating Voltage | 15–32 VDC |
| Standby Current | Low standby current operation |
| Communication Method | Group polling protocol |
| Test Method | External magnetic test switch |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Relative Humidity | 10% to 93% RH non-condensing |
| Housing Design | Low-profile detector body |
| Installation Type | Ceiling-mounted detector base installation |
| Application | Commercial fire detection systems |
| Signal Processing | Microprocessor-controlled detector communication |
| Weight | Approximately 0.35 lbs |
Information About ASD-IL
The ASD-IL is part of the Gamewell-FCI analog addressable smoke detector family, developed for integration with compatible fire alarm control panels using addressable communication protocols. The detector features a low-profile housing design, noise-resistant communication, and grouped polling technology that improves response speed during system events. It includes a built-in magnetic test switch for simplified functional testing and maintenance procedures. The ASD-IL is designed for indoor fire detection applications where stable ionization sensing and reliable panel communication are required.
Key Features:
- Ionization Smoke Detection: Provides fast response to combustion particles and smoke conditions using ionization sensing technology.
- Analog Addressable Communication: Allows individual detector identification and status monitoring through compatible Gamewell-FCI control panels.
- High-Speed Communication Protocol: Uses advanced polling technology to improve communication response compared with earlier detector designs.
- Group Polling Operation: Enables the control panel to quickly identify devices with changed conditions within a detector group.
- Low Standby Current: Reduces system power consumption during normal monitoring operation.
- Noise-Resistant Communication: Provides stable data transmission in electrically demanding environments.
- Low-Profile Housing: Features a compact design suitable for modern fire alarm installations.
- Magnetic Test Function: Includes an external magnet-activated functional test switch for maintenance checks.
- Wide Compatibility: Designed for use with compatible Gamewell-FCI analog addressable fire alarm systems.
- Supervised Operation: Provides continuous monitoring and status reporting to the connected fire alarm panel.
- Indoor Application Support: Suitable for commercial buildings and general fire detection installations.
- Simple Installation: Designed for straightforward mounting and integration with existing detector bases.
The ASD-IL delivers the reliability and precision required for analog addressable smoke detection and commercial fire alarm system protection.