Product Description P/N: SB364RG
Description
The General Electric SB364RG is a 200 A fusible bus plug designed to connect and protect three-phase electrical equipment supplied by compatible GE Spectra Series busway systems. General Electric part number SB364RG operates at up to 600 VAC and features a three-pole, three-wire configuration with a grounded connection and a specified 200 kA short-circuit rating. Its busway-mounted design provides a dedicated power takeoff point with fused circuit protection for commercial and industrial electrical distribution applications.
Technical Specifications
|
Condition |
New/Never Used Surplus |
|
Brand |
General Electric (GE) |
|
Category |
Electrical Distribution & Power Control |
|
Part Number |
SB364RG |
|
Subcategory |
Fusible Bus Plugs |
|
Product Type |
Switch-Operated Fusible Bus Plug |
|
Product Family |
Spectra Series |
|
Series / Frame |
SB |
|
Rated Current |
200 A |
|
Rated Voltage |
480/600 VAC |
|
Number of Poles |
3 |
|
Phase |
3-Phase |
|
Wire Configuration |
3-Wire with Ground |
|
Switch Type |
QMR Interrupter |
|
Fuse Compatibility |
Class H / Class R |
|
Short-Circuit Rating |
Up to 200 kA at 480 VAC, with Appropriate Fuses |
|
Fuse Inclusion |
Fuses Not Included |
|
Enclosure Rating |
NEMA 1 |
|
Enclosure Material |
Aluminum |
|
Mounting Type |
Busway Plug-In |
|
Compatible Equipment |
GE Spectra Series Busway |
|
Plug Assist |
Standard |
|
Grounding |
Grounding Stab |
|
Connection Terminals |
Mechanical Lugs |
|
Height |
18.75 in |
|
Width |
16 in |
|
Depth |
8.75 in |
|
Standards |
UL Listed |
|
UPC |
783175004560 |
|
Weight |
52 lb |
Information About SB364RG
The SB364RG is part of the General Electric Spectra Series SB family of busway plug-in units, developed for distributing electrical power from busway systems to connected equipment. Its aluminum enclosure houses a fusible disconnect assembly designed for three-phase applications with a nominal current rating of 200 amperes. The unit is intended for installation at compatible GE Spectra busway plug-in locations, where it provides a protected branch connection without requiring a separate feeder run from the main distribution panel. Its grounded construction and manually operated disconnect arrangement support electrical isolation during equipment servicing, subject to the installation and safety requirements of the connected system.
Key Features:
-
200 A Current Rating: Provides a rated power takeoff capacity of 200 amperes for compatible electrical distribution circuits.
-
600 VAC Maximum Voltage: Designed for three-phase electrical systems operating at 480 VAC or 600 VAC.
-
Three-Pole Configuration: Provides three-pole switching for three-phase power distribution.
-
Fusible Protection: Uses a fused disconnect arrangement to provide overcurrent protection with appropriately selected fuses.
-
200 kA Short-Circuit Rating: Supports the specified high short-circuit current rating when installed with the required protective components.
-
Spectra Busway Compatibility: Designed for compatible General Electric Spectra Series busway installations.
-
Plug-In Busway Connection: Provides an equipment power takeoff point directly from the busway distribution system.
-
Three-Wire Design: Supports three-phase, three-wire electrical distribution configurations.
-
Grounding Provision: Includes a grounding connection for integration with the equipment grounding system.
-
Aluminum Enclosure: Uses an aluminum housing to protect the internal electrical components.
-
SB Frame Design: Identified as an SB Series bus plug for matching busway applications.
-
UL Standard Compliance: Identified for use in electrical distribution installations subject to applicable UL requirements.
The SB364RG delivers the reliability and precision required for protected industrial power distribution, busway branch connections, and electrical equipment isolation.
Description
The General Electric SB364RG is a 200 A fusible bus plug designed to connect and protect three-phase electrical equipment supplied by compatible GE Spectra Series busway systems. General Electric part number SB364RG operates at up to 600 VAC and features a three-pole, three-wire configuration with a grounded connection and a specified 200 kA short-circuit rating. Its busway-mounted design provides a dedicated power takeoff point with fused circuit protection for commercial and industrial electrical distribution applications.
Technical Specifications
|
Condition |
New/Never Used Surplus |
|
Brand |
General Electric (GE) |
|
Category |
Electrical Distribution & Power Control |
|
Part Number |
SB364RG |
|
Subcategory |
Fusible Bus Plugs |
|
Product Type |
Switch-Operated Fusible Bus Plug |
|
Product Family |
Spectra Series |
|
Series / Frame |
SB |
|
Rated Current |
200 A |
|
Rated Voltage |
480/600 VAC |
|
Number of Poles |
3 |
|
Phase |
3-Phase |
|
Wire Configuration |
3-Wire with Ground |
|
Switch Type |
QMR Interrupter |
|
Fuse Compatibility |
Class H / Class R |
|
Short-Circuit Rating |
Up to 200 kA at 480 VAC, with Appropriate Fuses |
|
Fuse Inclusion |
Fuses Not Included |
|
Enclosure Rating |
NEMA 1 |
|
Enclosure Material |
Aluminum |
|
Mounting Type |
Busway Plug-In |
|
Compatible Equipment |
GE Spectra Series Busway |
|
Plug Assist |
Standard |
|
Grounding |
Grounding Stab |
|
Connection Terminals |
Mechanical Lugs |
|
Height |
18.75 in |
|
Width |
16 in |
|
Depth |
8.75 in |
|
Standards |
UL Listed |
|
UPC |
783175004560 |
|
Weight |
52 lb |
Information About SB364RG
The SB364RG is part of the General Electric Spectra Series SB family of busway plug-in units, developed for distributing electrical power from busway systems to connected equipment. Its aluminum enclosure houses a fusible disconnect assembly designed for three-phase applications with a nominal current rating of 200 amperes. The unit is intended for installation at compatible GE Spectra busway plug-in locations, where it provides a protected branch connection without requiring a separate feeder run from the main distribution panel. Its grounded construction and manually operated disconnect arrangement support electrical isolation during equipment servicing, subject to the installation and safety requirements of the connected system.
Key Features:
-
200 A Current Rating: Provides a rated power takeoff capacity of 200 amperes for compatible electrical distribution circuits.
-
600 VAC Maximum Voltage: Designed for three-phase electrical systems operating at 480 VAC or 600 VAC.
-
Three-Pole Configuration: Provides three-pole switching for three-phase power distribution.
-
Fusible Protection: Uses a fused disconnect arrangement to provide overcurrent protection with appropriately selected fuses.
-
200 kA Short-Circuit Rating: Supports the specified high short-circuit current rating when installed with the required protective components.
-
Spectra Busway Compatibility: Designed for compatible General Electric Spectra Series busway installations.
-
Plug-In Busway Connection: Provides an equipment power takeoff point directly from the busway distribution system.
-
Three-Wire Design: Supports three-phase, three-wire electrical distribution configurations.
-
Grounding Provision: Includes a grounding connection for integration with the equipment grounding system.
-
Aluminum Enclosure: Uses an aluminum housing to protect the internal electrical components.
-
SB Frame Design: Identified as an SB Series bus plug for matching busway applications.
-
UL Standard Compliance: Identified for use in electrical distribution installations subject to applicable UL requirements.
The SB364RG delivers the reliability and precision required for protected industrial power distribution, busway branch connections, and electrical equipment isolation.