General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection
General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection
General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection
    General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection
General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection

General Electric TED136150 E150 Thermal-Magnetic Molded Case Circuit Breaker with Fixed Trip Protection

Part #: TED136150 Manufactured by: General Electric
Regular price
$2,999.00
Sale price
$2,999.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The TED136150 is an E150-frame breaker for three-phase systems requiring thermal-magnetic circuit protection. Its defined ...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 8:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: TED136150
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro BBB Business Review
IQElectro is Not an authorized distributor for General Electric
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: TED136150

Description / Specifications

Description

The General Electric TED136150 is a three-pole molded case circuit breaker for protecting compatible power circuits against overloads and short circuits. Its 150 A current rating and voltage capability up to 600 Vac support commercial and industrial distribution applications.


 

Technical Specifications

Condition New/Never Used Surplus
Brand General Electric
Category Electrical Distribution
Part Number TED136150
Subcategory Molded Case Circuit Breakers
Product Family E150
Breaker Type TED
Rated Current 150 A
Number of Poles 3
Phase Three-phase
Maximum AC Voltage 600 Vac
AC Interrupting Ratings 18 kA at 240 Vac; 18 kA at 480 Vac; 14 kA at 600 Vac
DC Interrupting Ratings 10 kA at 250/500 VDC; prescribed pole wiring required
Trip Technology Thermal-magnetic
Trip Functions LI: Long-time and instantaneous
Trip Adjustment Fixed
Trip Unit Construction Non-interchangeable
Mounting Style Bolt-on; compatible mounting hardware required
Reverse Feed Suitable
Conductor Temperature Rating 75°C for this current rating
Weight 4.09 lb (1.86 kg)



Information About TED136150

The TED136150 is part of the General Electric E150 thermal-magnetic circuit breaker family. Its LI protection combines long-time overload response with instantaneous magnetic tripping. The fixed, non-interchangeable trip configuration provides predetermined protection settings for appropriately matched circuits. The manufacturer distinguishes the base catalog number from the WL version, which specifies copper/aluminum line and load lugs.

Key Features:

                                                          • Current Rating: Provides a 150 A rating for compatible branch or feeder circuits.
                                                          • Three-Pole Operation: Provides common-trip disconnection across three circuit poles.
                                                          • Thermal Protection: Responds to sustained overload conditions through the thermal trip mechanism.
                                                          • Magnetic Protection: Provides instantaneous tripping for sufficiently high fault currents.
                                                          • AC Voltage Capability: Supports applications rated up to 600 Vac.
                                                          • Interrupting Ratings: Specifies 18 kA at 240/480 Vac and 14 kA at 600 Vac.
                                                          • Fixed Trip Configuration: Incorporates non-adjustable long-time and instantaneous protection.
                                                          • Reverse-Feed Suitability: Identified by the manufacturer as suitable for reverse-feed applications.

                                                          The TED136150 delivers the reliability and precision required for overload and short-circuit protection in compatible electrical distribution installations.

                                                          Get fast quote and compatibility check
                                                          Compatibility check available   ·   Alternative parts suggested
                                                          Get a response to your request within 5 minutes
                                                          Talk to a real industrial automation specialist.
                                                          We verify compatibility, suggest alternatives, and provide fast quotes.
                                                          Something went wrong, please try again
                                                          Form image
                                                          Arty A.
                                                          Senior Sales Manager
                                                          Daniel S.
                                                          Parts Specialist
                                                          Request successfully sent!
                                                          Estimated response time: 1 to 5 minutes.
                                                          Description / Specifications

                                                          Description

                                                          The General Electric TED136150 is a three-pole molded case circuit breaker for protecting compatible power circuits against overloads and short circuits. Its 150 A current rating and voltage capability up to 600 Vac support commercial and industrial distribution applications.


                                                           

                                                          Technical Specifications

                                                          Condition New/Never Used Surplus
                                                          Brand General Electric
                                                          Category Electrical Distribution
                                                          Part Number TED136150
                                                          Subcategory Molded Case Circuit Breakers
                                                          Product Family E150
                                                          Breaker Type TED
                                                          Rated Current 150 A
                                                          Number of Poles 3
                                                          Phase Three-phase
                                                          Maximum AC Voltage 600 Vac
                                                          AC Interrupting Ratings 18 kA at 240 Vac; 18 kA at 480 Vac; 14 kA at 600 Vac
                                                          DC Interrupting Ratings 10 kA at 250/500 VDC; prescribed pole wiring required
                                                          Trip Technology Thermal-magnetic
                                                          Trip Functions LI: Long-time and instantaneous
                                                          Trip Adjustment Fixed
                                                          Trip Unit Construction Non-interchangeable
                                                          Mounting Style Bolt-on; compatible mounting hardware required
                                                          Reverse Feed Suitable
                                                          Conductor Temperature Rating 75°C for this current rating
                                                          Weight 4.09 lb (1.86 kg)



                                                          Information About TED136150

                                                          The TED136150 is part of the General Electric E150 thermal-magnetic circuit breaker family. Its LI protection combines long-time overload response with instantaneous magnetic tripping. The fixed, non-interchangeable trip configuration provides predetermined protection settings for appropriately matched circuits. The manufacturer distinguishes the base catalog number from the WL version, which specifies copper/aluminum line and load lugs.

                                                          Key Features:

                                                                                                                  • Current Rating: Provides a 150 A rating for compatible branch or feeder circuits.
                                                                                                                  • Three-Pole Operation: Provides common-trip disconnection across three circuit poles.
                                                                                                                  • Thermal Protection: Responds to sustained overload conditions through the thermal trip mechanism.
                                                                                                                  • Magnetic Protection: Provides instantaneous tripping for sufficiently high fault currents.
                                                                                                                  • AC Voltage Capability: Supports applications rated up to 600 Vac.
                                                                                                                  • Interrupting Ratings: Specifies 18 kA at 240/480 Vac and 14 kA at 600 Vac.
                                                                                                                  • Fixed Trip Configuration: Incorporates non-adjustable long-time and instantaneous protection.
                                                                                                                  • Reverse-Feed Suitability: Identified by the manufacturer as suitable for reverse-feed applications.

                                                                                                                  The TED136150 delivers the reliability and precision required for overload and short-circuit protection in compatible electrical distribution installations.

                                                                                                                  Check Out These Related Products