General Electric THN3364 Heavy Duty Non-Fusible Safety Disconnect Switch for Indoor Industrial Applications
- Regular price
- $745.00
- Sale price
- $745.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: THN3364
Description
The General Electric THN3364 is a heavy-duty, non-fusible safety switch for manually disconnecting power to commercial and industrial equipment. Its 200 A rating, three-pole construction, and NEMA 1 enclosure suit indoor installations requiring a dedicated disconnecting point.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Electrical Distribution |
| Part Number | THN3364 |
| Subcategory | Safety Disconnect Switches |
| Product Range | Spec-Setter |
| Duty Classification | Heavy duty |
| Rated Current | 200 A |
| AC Voltage Rating | 600 Vac |
| DC Voltage Rating | 250 VDC, subject to specified wiring configuration |
| Number of Poles | 3 |
| Number of Wires | 3 |
| Fuse Configuration | Non-fusible |
| Enclosure Rating | NEMA 1, indoor |
| Conductor Range | 2 AWG–250 kcmil, copper or aluminum |
| Three-Phase Motor Ratings | 60 hp at 240 Vac; 125 hp at 480 Vac; 150 hp at 600 Vac |
| DC Motor Rating | 40 hp at 250 VDC |
| Approximate Enclosure Dimensions | 31.5 in H × 13.3 in W × 5.1 in D, excluding handle |
| Listings | UL and cUL |
| Weight | 32 lb |
Information About THN3364
The THN3364 is part of the General Electric Spec-Setter safety switch range. Its three-pole, three-wire arrangement supports compatible power circuits rated up to 600 Vac. The non-fusible configuration provides switching and isolation, with overcurrent protection supplied elsewhere in the circuit. Its enclosed construction is intended for indoor mounting in accordance with the equipment’s installation requirements.
Key Features:
- Heavy-Duty Construction: Designed for commercial and industrial power-disconnection applications.
- Current Rating: Supports circuits requiring a 200 A rated safety switch.
- Three-Pole Switching: Disconnects three circuit conductors through a common operating mechanism.
- Non-Fusible Design: Provides a disconnecting function without integral fuse provisions.
- AC Voltage Rating: Rated for compatible circuits up to 600 Vac.
- Indoor Enclosure: Features a NEMA 1 enclosure for appropriate indoor locations.
- Motor Applications: Carries published horsepower ratings for compatible AC and DC motor circuits.
- Listed Equipment: Identified in the manufacturer’s catalog as UL and cUL listed.
The THN3364 delivers the reliability and precision required for manual power switching and equipment isolation in industrial electrical installations.
Description
The General Electric THN3364 is a heavy-duty, non-fusible safety switch for manually disconnecting power to commercial and industrial equipment. Its 200 A rating, three-pole construction, and NEMA 1 enclosure suit indoor installations requiring a dedicated disconnecting point.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Electrical Distribution |
| Part Number | THN3364 |
| Subcategory | Safety Disconnect Switches |
| Product Range | Spec-Setter |
| Duty Classification | Heavy duty |
| Rated Current | 200 A |
| AC Voltage Rating | 600 Vac |
| DC Voltage Rating | 250 VDC, subject to specified wiring configuration |
| Number of Poles | 3 |
| Number of Wires | 3 |
| Fuse Configuration | Non-fusible |
| Enclosure Rating | NEMA 1, indoor |
| Conductor Range | 2 AWG–250 kcmil, copper or aluminum |
| Three-Phase Motor Ratings | 60 hp at 240 Vac; 125 hp at 480 Vac; 150 hp at 600 Vac |
| DC Motor Rating | 40 hp at 250 VDC |
| Approximate Enclosure Dimensions | 31.5 in H × 13.3 in W × 5.1 in D, excluding handle |
| Listings | UL and cUL |
| Weight | 32 lb |
Information About THN3364
The THN3364 is part of the General Electric Spec-Setter safety switch range. Its three-pole, three-wire arrangement supports compatible power circuits rated up to 600 Vac. The non-fusible configuration provides switching and isolation, with overcurrent protection supplied elsewhere in the circuit. Its enclosed construction is intended for indoor mounting in accordance with the equipment’s installation requirements.
Key Features:
- Heavy-Duty Construction: Designed for commercial and industrial power-disconnection applications.
- Current Rating: Supports circuits requiring a 200 A rated safety switch.
- Three-Pole Switching: Disconnects three circuit conductors through a common operating mechanism.
- Non-Fusible Design: Provides a disconnecting function without integral fuse provisions.
- AC Voltage Rating: Rated for compatible circuits up to 600 Vac.
- Indoor Enclosure: Features a NEMA 1 enclosure for appropriate indoor locations.
- Motor Applications: Carries published horsepower ratings for compatible AC and DC motor circuits.
- Listed Equipment: Identified in the manufacturer’s catalog as UL and cUL listed.
The THN3364 delivers the reliability and precision required for manual power switching and equipment isolation in industrial electrical installations.