General Electric TP1616SS Power Break I Insulated Case Circuit Breaker with MicroVersaTrip Plus Protection
- Regular price
- $9,999.00
- Sale price
- $9,999.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: TP1616SS
Description
The General Electric TP1616SS is a Power Break I insulated case circuit breaker for protecting high-current industrial distribution circuits. The supplied configuration combines a 1600 A frame and trip rating with a MicroVersaTrip Plus C216LSIGR trip unit providing long-time, short-time, instantaneous, and ground-fault protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Electrical Distribution |
| Part Number | TP1616SS |
| Subcategory | Insulated Case Circuit Breakers |
| Product Family | Power Break I |
| Breaker Type | TP |
| Frame Rating | 1600 A |
| Supplied Trip Rating | 1600 A; verify installed rating plug |
| Number of Poles | 3 |
| Phase | Three-phase |
| Maximum Voltage Rating | 600 Vac |
| Specified Interrupting Rating | 65 kA at 480 Vac; verify breaker nameplate |
| Trip Technology | Electronic, solid-state |
| Supplied Trip Unit | MicroVersaTrip Plus |
| Trip Unit Model | C216LSIGR |
| Trip Functions | LSIG: Long-time, short-time, instantaneous, and ground fault |
| Operator Type | Manual |
| Mounting Style | Stationary, bolt-on |
| Case Construction | Insulated case |
| Weight | 81 lb (36.74 kg) |
Information About TP1616SS
The TP1616SS is part of the General Electric Power Break I family and uses a stationary, bolt-on mounting arrangement. Its three-pole construction supports coordinated interruption of compatible three-phase power circuits. The supplied unit is identified with a manually operated mechanism and a maximum voltage rating of 600 Vac. Protection settings and effective current rating depend on the installed trip unit, rating plug, and associated system configuration.
Key Features:
- High-Current Frame: Provides a 1600 A frame rating for compatible industrial distribution equipment.
- Three-Pole Construction: Opens three circuit poles through a common operating mechanism.
- Electronic Trip Unit: Incorporates the specified MicroVersaTrip Plus C216LSIGR programmer.
- Long-Time Protection: Responds to sustained overload conditions according to the configured settings.
- Short-Time Protection: Provides delayed overcurrent response for coordination with downstream devices.
- Instantaneous Protection: Responds to sufficiently high fault currents without an intentional time delay.
- Ground-Fault Protection: Provides the ground-fault function identified by the LSIG configuration.
- Manual Operation: Uses a manually operated mechanism within the stationary breaker assembly.
The TP1616SS delivers the reliability and precision required for coordinated overcurrent and ground-fault protection in industrial power distribution systems.
Description
The General Electric TP1616SS is a Power Break I insulated case circuit breaker for protecting high-current industrial distribution circuits. The supplied configuration combines a 1600 A frame and trip rating with a MicroVersaTrip Plus C216LSIGR trip unit providing long-time, short-time, instantaneous, and ground-fault protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | General Electric |
| Category | Electrical Distribution |
| Part Number | TP1616SS |
| Subcategory | Insulated Case Circuit Breakers |
| Product Family | Power Break I |
| Breaker Type | TP |
| Frame Rating | 1600 A |
| Supplied Trip Rating | 1600 A; verify installed rating plug |
| Number of Poles | 3 |
| Phase | Three-phase |
| Maximum Voltage Rating | 600 Vac |
| Specified Interrupting Rating | 65 kA at 480 Vac; verify breaker nameplate |
| Trip Technology | Electronic, solid-state |
| Supplied Trip Unit | MicroVersaTrip Plus |
| Trip Unit Model | C216LSIGR |
| Trip Functions | LSIG: Long-time, short-time, instantaneous, and ground fault |
| Operator Type | Manual |
| Mounting Style | Stationary, bolt-on |
| Case Construction | Insulated case |
| Weight | 81 lb (36.74 kg) |
Information About TP1616SS
The TP1616SS is part of the General Electric Power Break I family and uses a stationary, bolt-on mounting arrangement. Its three-pole construction supports coordinated interruption of compatible three-phase power circuits. The supplied unit is identified with a manually operated mechanism and a maximum voltage rating of 600 Vac. Protection settings and effective current rating depend on the installed trip unit, rating plug, and associated system configuration.
Key Features:
- High-Current Frame: Provides a 1600 A frame rating for compatible industrial distribution equipment.
- Three-Pole Construction: Opens three circuit poles through a common operating mechanism.
- Electronic Trip Unit: Incorporates the specified MicroVersaTrip Plus C216LSIGR programmer.
- Long-Time Protection: Responds to sustained overload conditions according to the configured settings.
- Short-Time Protection: Provides delayed overcurrent response for coordination with downstream devices.
- Instantaneous Protection: Responds to sufficiently high fault currents without an intentional time delay.
- Ground-Fault Protection: Provides the ground-fault function identified by the LSIG configuration.
- Manual Operation: Uses a manually operated mechanism within the stationary breaker assembly.
The TP1616SS delivers the reliability and precision required for coordinated overcurrent and ground-fault protection in industrial power distribution systems.