Product Description P/N: GV3P50
Description
The Schneider Electric GV3P50 is a robust non-reversing manual motor starter designed for reliable protection and control of three-phase motors. With an adjustable thermal overload range of 37 to 50 A, it supports motor ratings up to 40 HP and includes a rotary-knob interface for straightforward manual operation. Its compact IP20/IK09 enclosure and ambient-compensated bimetal relay ensure dependable performance across demanding industrial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Contactors & Starters |
| Part Number | GV3P50 |
| Subcategory | Starter |
| Series | GV3 |
| Type | Non-Reversing Manual Motor Starter |
| Phase | 3-Phase |
| Voltage Rating | 600 VAC |
| Frequency Rating | 50/60 Hz |
| Amperage Rating | 37–50 A (adjustable) |
| Number of Poles | 3 |
| Motor Power | 3 HP, 7.5 HP, 10 HP, 30 HP, 40 HP |
| Control Type | Rotary knob |
| Reset Type | Manual |
| Overload Relay Type | Ambient-compensated bimetal |
| Connection Type | Screw clamp |
| Operating Cycles | 50,000 cycles |
| Enclosure Type | IP20 / IK09 |
| Operating Temperature | –20 to 60 °C |
| Dimensions | 55 mm W × 136 mm D × 132 mm H (2.17 in × 5.35 in × 5.2 in) |
Information About GV3P50
The GV3P50 is part of Schneider Electric’s TeSys GV3 range, engineered to combine manual motor control, thermal overload protection, and circuit isolation into one compact device. Supporting motor full-load currents up to 50 A, it accommodates multiple horsepower levels across a wide motor range, making it suitable for pumps, conveyors, compressors, and various industrial machines. Its ambient-compensated bimetallic overload relay maintains accuracy despite temperature changes, helping ensure dependable motor protection. The rotary-knob design provides intuitive start/stop control, while its rugged IP20/IK09 enclosure enhances durability in industrial environments. With high endurance up to 50,000 operating cycles and compliance with global standards, the GV3P50 integrates easily into control panels requiring reliable motor circuit protection.
Key Features:
- Adjustable thermal overload range (37–50 A): enables precise protection for motors across multiple horsepower ratings.
- Integrated manual motor control: combines isolation, overload protection, and on/off control in a single three-pole device.
- Ambient-compensated bimetal relay: maintains accurate trip characteristics under varying temperature conditions.
- Rotary-knob operation: provides straightforward start/stop control and manual reset functionality.
- High mechanical endurance: rated for 50,000 AC-3 cycles to support long-term industrial operation.
- IP20/IK09 enclosure: ensures reliable protection in control panel environments with enhanced impact resistance.
- Wide application range: supports motors from 3 HP to 40 HP across 600 VAC three-phase power systems.
- Screw-clamp terminals: ensure secure and stable wiring connections for industrial installations.
The GV3P50 delivers the reliability and precision required for dependable manual motor control, consistent overload protection, and long-service performance in industrial motor-driven systems.
Description
The Schneider Electric GV3P50 is a robust non-reversing manual motor starter designed for reliable protection and control of three-phase motors. With an adjustable thermal overload range of 37 to 50 A, it supports motor ratings up to 40 HP and includes a rotary-knob interface for straightforward manual operation. Its compact IP20/IK09 enclosure and ambient-compensated bimetal relay ensure dependable performance across demanding industrial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Contactors & Starters |
| Part Number | GV3P50 |
| Subcategory | Starter |
| Series | GV3 |
| Type | Non-Reversing Manual Motor Starter |
| Phase | 3-Phase |
| Voltage Rating | 600 VAC |
| Frequency Rating | 50/60 Hz |
| Amperage Rating | 37–50 A (adjustable) |
| Number of Poles | 3 |
| Motor Power | 3 HP, 7.5 HP, 10 HP, 30 HP, 40 HP |
| Control Type | Rotary knob |
| Reset Type | Manual |
| Overload Relay Type | Ambient-compensated bimetal |
| Connection Type | Screw clamp |
| Operating Cycles | 50,000 cycles |
| Enclosure Type | IP20 / IK09 |
| Operating Temperature | –20 to 60 °C |
| Dimensions | 55 mm W × 136 mm D × 132 mm H (2.17 in × 5.35 in × 5.2 in) |
Information About GV3P50
The GV3P50 is part of Schneider Electric’s TeSys GV3 range, engineered to combine manual motor control, thermal overload protection, and circuit isolation into one compact device. Supporting motor full-load currents up to 50 A, it accommodates multiple horsepower levels across a wide motor range, making it suitable for pumps, conveyors, compressors, and various industrial machines. Its ambient-compensated bimetallic overload relay maintains accuracy despite temperature changes, helping ensure dependable motor protection. The rotary-knob design provides intuitive start/stop control, while its rugged IP20/IK09 enclosure enhances durability in industrial environments. With high endurance up to 50,000 operating cycles and compliance with global standards, the GV3P50 integrates easily into control panels requiring reliable motor circuit protection.
Key Features:
- Adjustable thermal overload range (37–50 A): enables precise protection for motors across multiple horsepower ratings.
- Integrated manual motor control: combines isolation, overload protection, and on/off control in a single three-pole device.
- Ambient-compensated bimetal relay: maintains accurate trip characteristics under varying temperature conditions.
- Rotary-knob operation: provides straightforward start/stop control and manual reset functionality.
- High mechanical endurance: rated for 50,000 AC-3 cycles to support long-term industrial operation.
- IP20/IK09 enclosure: ensures reliable protection in control panel environments with enhanced impact resistance.
- Wide application range: supports motors from 3 HP to 40 HP across 600 VAC three-phase power systems.
- Screw-clamp terminals: ensure secure and stable wiring connections for industrial installations.
The GV3P50 delivers the reliability and precision required for dependable manual motor control, consistent overload protection, and long-service performance in industrial motor-driven systems.