HDA36030 | Schneider Electric Circuit Breaker
- Regular price
- $729.00
- Sale price
- $729.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: HDA36030
Description
PowerPacT H-Frame circuit breakers are engineered to safeguard electrical systems against overloads and short circuits. These circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. The HDA36030 PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers feature dual-break rotating contacts that minimize peak current during a short circuit event.ย
ย
ย
Technical Specifications
|
Part Numberย |
HDA36030ย |
|
Categoryย |
Circuit Breakerย |
|
Subcategoryย |
Molded Case Circuit Breakerย |
|
Rangeย |
PowerPactย |
|
Product nameย |
PowerPact Hย |
|
Product or Component Typeย |
Circuit breakerย |
|
Device Applicationย |
Distributionย |
|
Line Rated Currentย |
30 Aย |
|
Number of Polesย |
3Pย |
|
Protected poles descriptionย |
3tย |
|
Control Typeย |
Toggleย |
|
Breaking capacity codeย |
Dย |
|
[Ue] rated operational voltageย |
690 V AC 50/60 Hz IEC 60947-3ย |
|
Network Frequencyย |
50/60 Hzย |
|
[Uimp] rated impulse withstand voltageย |
8 kV IEC 60947-2ย |
|
Trip unit technologyย |
Thermal-magneticย |
|
Magnetic tripping currentย |
750 Aย |
|
Magnetic hold currentย |
350 Aย |
|
Continuous current ratingย |
80 %ย |
|
[Ui] rated insulation voltageย |
750 V IEC 60947-2ย |
|
Suitability for isolationย |
Yes IEC 60947-2ย |
|
Utilisation categoryย |
Category Aย |
|
AWG gaugeย |
AWG 14...AWG 3/0 aluminium/copper terminalย |
|
Local signallingย |
Switched off (OFF) 1 trip indicator greenย |
|
Mounting modeย |
I-Line bracketย |
|
Mounting Supportย |
Bracketย |
ย
ย
Information About HDA36030
The HDA36030 is a PowerPacT H-Frame circuit breaker. It is rated at 30A and designed with 3 poles for electrical system protection against overloads and short circuits. The unit operates at 600VAC with a breaking capacity of 14kA. PowerPacT H-Frame circuit breakers are offered with thermal magnetic or Micrologic electronic trip protection units. This specific model utilizes thermal magnetic trip technology. All PowerPacT H-Frame circuit breakers are designed with dual-break rotating contacts that effectively minimize peak current during a short circuit fault.ย
This circuit breaker includes an integral push-to-trip button on the cover, which allows manual tripping of the breaker. PowerPacT H-Frame circuit breakers are available in both 2-pole and 3-pole configurations, with options for unit mount and I-Line constructions. The HDA36030 is built for I-Line construction, which simplifies installation and removal in I-Line applications. The circuit breaker is equipped with I-Line terminations on the line side and mechanical lugs on the load side.ย
Description
PowerPacT H-Frame circuit breakers are engineered to safeguard electrical systems against overloads and short circuits. These circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. The HDA36030 PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers feature dual-break rotating contacts that minimize peak current during a short circuit event.ย
ย
ย
Technical Specifications
|
Part Numberย |
HDA36030ย |
|
Categoryย |
Circuit Breakerย |
|
Subcategoryย |
Molded Case Circuit Breakerย |
|
Rangeย |
PowerPactย |
|
Product nameย |
PowerPact Hย |
|
Product or Component Typeย |
Circuit breakerย |
|
Device Applicationย |
Distributionย |
|
Line Rated Currentย |
30 Aย |
|
Number of Polesย |
3Pย |
|
Protected poles descriptionย |
3tย |
|
Control Typeย |
Toggleย |
|
Breaking capacity codeย |
Dย |
|
[Ue] rated operational voltageย |
690 V AC 50/60 Hz IEC 60947-3ย |
|
Network Frequencyย |
50/60 Hzย |
|
[Uimp] rated impulse withstand voltageย |
8 kV IEC 60947-2ย |
|
Trip unit technologyย |
Thermal-magneticย |
|
Magnetic tripping currentย |
750 Aย |
|
Magnetic hold currentย |
350 Aย |
|
Continuous current ratingย |
80 %ย |
|
[Ui] rated insulation voltageย |
750 V IEC 60947-2ย |
|
Suitability for isolationย |
Yes IEC 60947-2ย |
|
Utilisation categoryย |
Category Aย |
|
AWG gaugeย |
AWG 14...AWG 3/0 aluminium/copper terminalย |
|
Local signallingย |
Switched off (OFF) 1 trip indicator greenย |
|
Mounting modeย |
I-Line bracketย |
|
Mounting Supportย |
Bracketย |
ย
ย
Information About HDA36030
The HDA36030 is a PowerPacT H-Frame circuit breaker. It is rated at 30A and designed with 3 poles for electrical system protection against overloads and short circuits. The unit operates at 600VAC with a breaking capacity of 14kA. PowerPacT H-Frame circuit breakers are offered with thermal magnetic or Micrologic electronic trip protection units. This specific model utilizes thermal magnetic trip technology. All PowerPacT H-Frame circuit breakers are designed with dual-break rotating contacts that effectively minimize peak current during a short circuit fault.ย
This circuit breaker includes an integral push-to-trip button on the cover, which allows manual tripping of the breaker. PowerPacT H-Frame circuit breakers are available in both 2-pole and 3-pole configurations, with options for unit mount and I-Line constructions. The HDA36030 is built for I-Line construction, which simplifies installation and removal in I-Line applications. The circuit breaker is equipped with I-Line terminations on the line side and mechanical lugs on the load side.ย