HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch
HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch
HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch
    HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch
HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch

HK06NB123 | Carrier 1.81" WC SPST Furnace Air Pressure Switch

Part #: HK06NB123 Manufactured by: Carrier
Regular price
$87.00
Sale price
$87.00
Regular price
32 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
HK06NB123 - Furnace Air Pressure Switch Replaces Carrier Bryant Payne
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: HK06NB123
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Carrier
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: HK06NB123

Description / Specifications

Description 

The Carrier HK06NB123 is a furnace air pressure switch designed to monitor system airflow and support safe ignition sequencing. Built to Carrier specifications, it replaces older pressure switch models while maintaining proper combustion operation. The HK06NB123 ensures the furnace activates only when correct draft and pressure conditions are present.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Carrier
Category Sensors & Switches
Part Number HK06NB123
Subcategory Pressure Switch
Switch Type SPST (Single-Pole Single-Throw)
Pressure Rating 1.81" WC
Function Airflow and draft pressure monitoring
Application Residential furnace safety circuit
Compatibility Carrier and BDP furnace systems
Electrical Terminals Standard spade connectors
Tubing Connection Standard furnace pressure tubing
Housing Style Enclosed pressure-actuated switch
Operation Mode Opens/closes based on sensed pressure
Use Case Combustion safety and airflow verification

  

 

Information About HK06NB123

The HK06NB123 is part of Carrier’s line of furnace pressure switches and is engineered to control airflow verification within the heating system. Featuring a single-pole, single-throw (SPST) design rated at 1.81 inches water column, it responds to changes in draft pressure with reliable switching accuracy. The component integrates readily with compatible Carrier furnaces, using standard tubing and wiring connections for straightforward installation. Commonly applied in residential heating systems, it supports combustion safety and airflow integrity by preventing operation under improper pressure conditions.

Key Features:

  • 1.81" WC rating: Calibrated for proper draft pressure detection in Carrier furnaces.
  • SPST switch configuration: Provides simple and reliable open/close control.
  • Safety interlock function: Ensures furnace operation only under correct airflow conditions.
  • OEM-compatible design: Matches Carrier specifications for replacement applications.
  • Durable housing: Resistant to typical furnace heat and environmental conditions.
  • Standard tubing and terminals: Supports quick installation and service.
  • Accurate pressure response: Maintains proper combustion and system performance.
  • Suitable for residential systems: Aligns with common Carrier heating models.

The HK06NB123 delivers the reliability and precision required for consistent furnace airflow monitoring and safe ignition control.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Carrier HK06NB123 is a furnace air pressure switch designed to monitor system airflow and support safe ignition sequencing. Built to Carrier specifications, it replaces older pressure switch models while maintaining proper combustion operation. The HK06NB123 ensures the furnace activates only when correct draft and pressure conditions are present.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Carrier
Category Sensors & Switches
Part Number HK06NB123
Subcategory Pressure Switch
Switch Type SPST (Single-Pole Single-Throw)
Pressure Rating 1.81" WC
Function Airflow and draft pressure monitoring
Application Residential furnace safety circuit
Compatibility Carrier and BDP furnace systems
Electrical Terminals Standard spade connectors
Tubing Connection Standard furnace pressure tubing
Housing Style Enclosed pressure-actuated switch
Operation Mode Opens/closes based on sensed pressure
Use Case Combustion safety and airflow verification

  

 

Information About HK06NB123

The HK06NB123 is part of Carrier’s line of furnace pressure switches and is engineered to control airflow verification within the heating system. Featuring a single-pole, single-throw (SPST) design rated at 1.81 inches water column, it responds to changes in draft pressure with reliable switching accuracy. The component integrates readily with compatible Carrier furnaces, using standard tubing and wiring connections for straightforward installation. Commonly applied in residential heating systems, it supports combustion safety and airflow integrity by preventing operation under improper pressure conditions.

Key Features:

  • 1.81" WC rating: Calibrated for proper draft pressure detection in Carrier furnaces.
  • SPST switch configuration: Provides simple and reliable open/close control.
  • Safety interlock function: Ensures furnace operation only under correct airflow conditions.
  • OEM-compatible design: Matches Carrier specifications for replacement applications.
  • Durable housing: Resistant to typical furnace heat and environmental conditions.
  • Standard tubing and terminals: Supports quick installation and service.
  • Accurate pressure response: Maintains proper combustion and system performance.
  • Suitable for residential systems: Aligns with common Carrier heating models.

The HK06NB123 delivers the reliability and precision required for consistent furnace airflow monitoring and safe ignition control.

Check Out These Related Products