Product Description P/N: HLD3600
Description
The Eaton HLD3600 is a three-pole molded case circuit breaker designed for high-capacity protection of three-phase electrical distribution systems. It is rated for 600 amps at 600 volts and provides thermal magnetic protection with long-time and instantaneous trip functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton |
| Category | Circuit Breaker |
| Part Number | HLD3600 |
| Subcategory | Molded Case Circuit Breaker |
| Family | Series C |
| Type | HLD |
| Frame Type | L Frame |
| Rated Voltage | 600 VAC |
| Rated Current | 600 A |
| Interrupt Rating | 65 kA at 480 V |
| Protection Type | Thermal Magnetic |
| Trip Functions | Long-Time and Instantaneous (LI) |
| Number of Poles | 3 |
| Phase | Three-phase |
| Connection Type | Feed-Thru |
Information About HLD3600
The HLD3600 is part of Eaton’s Series C molded case circuit breaker lineup, engineered for demanding industrial and commercial power distribution applications. Its L-frame construction supports high current ratings while maintaining mechanical strength and thermal stability. The non-interchangeable thermal magnetic trip unit delivers consistent long-time overload protection combined with instantaneous short-circuit interruption. This circuit breaker is commonly installed in switchboards and distribution panels where feed-thru wiring and high interrupting capacity are required.
Key Features
- Three-pole molded case design: Provides coordinated protection and isolation across all phases in three-phase electrical systems.
- 600 amp continuous current rating: Suitable for main and feeder circuit applications with high load requirements.
- Thermal magnetic protection system: Combines long-time overload sensing with instantaneous magnetic short-circuit response.
- Long-time and instantaneous trip functions: Ensures dependable response to sustained overcurrent and sudden fault conditions.
- High interrupting capacity: Rated at 65 kA at 480 V for use in systems with high available fault current.
- Feed-thru connection configuration: Allows efficient conductor routing through the breaker for streamlined panel layouts.
- L-frame Series C construction: Delivers durability and reliable performance in harsh industrial environments.
The HLD3600 delivers the reliability and precision required for protecting high-capacity three-phase electrical distribution systems in industrial and commercial power applications.
Description
The Eaton HLD3600 is a three-pole molded case circuit breaker designed for high-capacity protection of three-phase electrical distribution systems. It is rated for 600 amps at 600 volts and provides thermal magnetic protection with long-time and instantaneous trip functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Eaton |
| Category | Circuit Breaker |
| Part Number | HLD3600 |
| Subcategory | Molded Case Circuit Breaker |
| Family | Series C |
| Type | HLD |
| Frame Type | L Frame |
| Rated Voltage | 600 VAC |
| Rated Current | 600 A |
| Interrupt Rating | 65 kA at 480 V |
| Protection Type | Thermal Magnetic |
| Trip Functions | Long-Time and Instantaneous (LI) |
| Number of Poles | 3 |
| Phase | Three-phase |
| Connection Type | Feed-Thru |
Information About HLD3600
The HLD3600 is part of Eaton’s Series C molded case circuit breaker lineup, engineered for demanding industrial and commercial power distribution applications. Its L-frame construction supports high current ratings while maintaining mechanical strength and thermal stability. The non-interchangeable thermal magnetic trip unit delivers consistent long-time overload protection combined with instantaneous short-circuit interruption. This circuit breaker is commonly installed in switchboards and distribution panels where feed-thru wiring and high interrupting capacity are required.
Key Features
- Three-pole molded case design: Provides coordinated protection and isolation across all phases in three-phase electrical systems.
- 600 amp continuous current rating: Suitable for main and feeder circuit applications with high load requirements.
- Thermal magnetic protection system: Combines long-time overload sensing with instantaneous magnetic short-circuit response.
- Long-time and instantaneous trip functions: Ensures dependable response to sustained overcurrent and sudden fault conditions.
- High interrupting capacity: Rated at 65 kA at 480 V for use in systems with high available fault current.
- Feed-thru connection configuration: Allows efficient conductor routing through the breaker for streamlined panel layouts.
- L-frame Series C construction: Delivers durability and reliable performance in harsh industrial environments.
The HLD3600 delivers the reliability and precision required for protecting high-capacity three-phase electrical distribution systems in industrial and commercial power applications.