Product Description P/N: HOM220GFI
Description
The Schneider Electric HOM220GFI is a Homeline series miniature circuit breaker designed to provide combined overcurrent and ground fault protection. This 2-pole breaker is rated at 20 A and operates at 120/240 V AC with a 10 kA interrupting capacity. It incorporates Class A GFCI functionality to enhance personnel safety in residential and light commercial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | HOM220GFI |
| Subcategory | Molded Case Circuit Breaker |
| Series / Range | Homeline |
| Breaker Type | Miniature circuit breaker |
| Current Rating | 20 A |
| Voltage Rating | 120/240 V AC |
| Number of Poles | 2 |
| Mounting Type | Plug-in |
| Short Circuit Current Rating | 10 kA |
| Ground Fault Protection | Class A (6 mA) |
| Number of Spaces Required | 2 |
| HACR Rated | Yes |
| Certifications | UL Listed |
| Electrical Connection | Screw clamp terminals |
Information About HOM220GFI
The HOM220GFI is a Schneider Electric Homeline circuit breaker engineered for use in compatible Homeline load centers. It features a compact two-pole design that supports efficient installation while maintaining dependable electrical performance. The breaker integrates Class A ground fault protection to detect leakage currents exceeding 6 mA, in addition to standard overload and short-circuit protection. It is commonly used in residential and light commercial systems where enhanced safety and standardized Homeline compatibility are required.
Key Features
- Homeline Series Design: Developed for use in Schneider Electric Homeline load centers, ensuring proper fit and reliable performance.
- 20 Amp Continuous Rating: Suitable for branch circuits requiring combined overcurrent and ground fault protection.
- Two-Pole Configuration: Supports 120/240 V multi-wire and two-pole circuit applications.
- Class A GFCI Protection: Trips at ground fault currents above 6 mA to reduce the risk of electric shock.
- 10 kA Interrupting Capacity: Provides effective fault interruption for residential and light commercial installations.
- Plug-In Mounting: Allows fast, secure installation without additional mounting hardware.
- HACR Rated Construction: Approved for heating, air conditioning, and refrigeration circuit applications.
The HOM220GFI delivers the reliability and precision required for integrated ground fault and overcurrent protection in Schneider Electric Homeline electrical distribution systems.
Description
The Schneider Electric HOM220GFI is a Homeline series miniature circuit breaker designed to provide combined overcurrent and ground fault protection. This 2-pole breaker is rated at 20 A and operates at 120/240 V AC with a 10 kA interrupting capacity. It incorporates Class A GFCI functionality to enhance personnel safety in residential and light commercial applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | HOM220GFI |
| Subcategory | Molded Case Circuit Breaker |
| Series / Range | Homeline |
| Breaker Type | Miniature circuit breaker |
| Current Rating | 20 A |
| Voltage Rating | 120/240 V AC |
| Number of Poles | 2 |
| Mounting Type | Plug-in |
| Short Circuit Current Rating | 10 kA |
| Ground Fault Protection | Class A (6 mA) |
| Number of Spaces Required | 2 |
| HACR Rated | Yes |
| Certifications | UL Listed |
| Electrical Connection | Screw clamp terminals |
Information About HOM220GFI
The HOM220GFI is a Schneider Electric Homeline circuit breaker engineered for use in compatible Homeline load centers. It features a compact two-pole design that supports efficient installation while maintaining dependable electrical performance. The breaker integrates Class A ground fault protection to detect leakage currents exceeding 6 mA, in addition to standard overload and short-circuit protection. It is commonly used in residential and light commercial systems where enhanced safety and standardized Homeline compatibility are required.
Key Features
- Homeline Series Design: Developed for use in Schneider Electric Homeline load centers, ensuring proper fit and reliable performance.
- 20 Amp Continuous Rating: Suitable for branch circuits requiring combined overcurrent and ground fault protection.
- Two-Pole Configuration: Supports 120/240 V multi-wire and two-pole circuit applications.
- Class A GFCI Protection: Trips at ground fault currents above 6 mA to reduce the risk of electric shock.
- 10 kA Interrupting Capacity: Provides effective fault interruption for residential and light commercial installations.
- Plug-In Mounting: Allows fast, secure installation without additional mounting hardware.
- HACR Rated Construction: Approved for heating, air conditioning, and refrigeration circuit applications.
The HOM220GFI delivers the reliability and precision required for integrated ground fault and overcurrent protection in Schneider Electric Homeline electrical distribution systems.