Part #: HON-DACT-DS Manufactured by: Honeywell
Regular price
$1,259.00
Sale price
$1,259.00
Regular price
$0.00
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The HON-DACT-DS is a fire-alarm communicator module engineered to provide dual-line telephone reporting from compatible Ho...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: HON-DACT-DS
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Honeywell
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: HON-DACT-DS

Description / Specifications

Description 

The Honeywell HON-DACT-DS DS Dialer is a dual-line fire alarm communicator designed to report system status from a fire alarm control panel to a central monitoring station. It supports integration with listed fire alarm panels and provides secure, automatic reporting over the public switched telephone network.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category Fire Safety
Part Number HON-DACT-DS
Subcategory Fire Alarm Control
Communication Lines 2 (primary and backup POTS lines)
Protocol Supported Ademco® Contact ID
Operating Voltage Range 18 VDC – 30 VDC
Typical Current Draw ~200 mA @ 18 V, ~150 mA @ 24 V
Operating Temperature 32 °F to 120 °F (0 °C to 49 °C)
Storage Temperature 14 °F to 140 °F (-10 °C to +60 °C)
Relative Humidity 1% – 93% non-condensing
Listings & Approvals ETL Listed (Control No. 5025335) for UL 864; FCC ID 1W6AL02ACGWMB
Dimensions (H×W×D) 10 in × 2¾ in × 8 in
Weight 2 lbs

 

 

Information About HON-DACT-DS

The HON-DACT-DS is a dedicated dialer unit from Honeywell’s fire-life safety communications product line, engineered to interface with compatible fire alarm control panels such as the NOTIFIER ONYX series, INSPIRE series and the Gamewell‑FCI E3/S3 series. It comes in a red surface-mount enclosure and occupies two POTS (plain old telephone service) lines for primary and backup communications. The unit monitors line voltage, seizes the line if needed, sends centrally-station-formatted signals (Contact ID protocol) for alarms, troubles, supervisories and AC power loss, and provides LED status indicators for connectivity and fault conditions.

Key Features:

  • Dual Telephone-Line Support: Provides primary and backup line paths for reliable central station reporting.
  • Contact ID Protocol Compliance: Supports prevailing central-station reporting format for fire alarm communications.
  • Line Seizure Capability: Automatically seizes the local phone line to ensure prompt reporting over POTS.
  • Line-Voltage Monitoring: Detects loss or sag of the telephone line and reports as a trouble condition.
  • Compatible Panel Support: Designed to interface out-of-the-box with Notifier ONYX/INSPIRE and Gamewell-FCI E3/S3 panels.
  • LED Status Indicators: Front panel LEDs show Lost Panel Connection, Central Station Handshake Signal and Communication Failure.
  • Compact Surface Mount Enclosure: Housed in a red cabinet, external to the fire alarm panel, for ease of installation.
  • Comprehensive Event Reporting: Reports alarms, troubles, supervisory signals, NAC trouble, panel off-normal, and AC power loss.
  • UL/ETL and FCC Approvals: Electro-mechanical listing to UL 864 standard and FCC ID compliance for telecom interface.
  • Seismic Mounting-Capable: Accepts seismic mounting hardware for installation in IBC/IBC-zone locations when required.

The HON-DACT-DS DS Dialer delivers the required communication reliability and compatibility for monitored fire alarm installations.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Honeywell HON-DACT-DS DS Dialer is a dual-line fire alarm communicator designed to report system status from a fire alarm control panel to a central monitoring station. It supports integration with listed fire alarm panels and provides secure, automatic reporting over the public switched telephone network.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category Fire Safety
Part Number HON-DACT-DS
Subcategory Fire Alarm Control
Communication Lines 2 (primary and backup POTS lines)
Protocol Supported Ademco® Contact ID
Operating Voltage Range 18 VDC – 30 VDC
Typical Current Draw ~200 mA @ 18 V, ~150 mA @ 24 V
Operating Temperature 32 °F to 120 °F (0 °C to 49 °C)
Storage Temperature 14 °F to 140 °F (-10 °C to +60 °C)
Relative Humidity 1% – 93% non-condensing
Listings & Approvals ETL Listed (Control No. 5025335) for UL 864; FCC ID 1W6AL02ACGWMB
Dimensions (H×W×D) 10 in × 2¾ in × 8 in
Weight 2 lbs

 

 

Information About HON-DACT-DS

The HON-DACT-DS is a dedicated dialer unit from Honeywell’s fire-life safety communications product line, engineered to interface with compatible fire alarm control panels such as the NOTIFIER ONYX series, INSPIRE series and the Gamewell‑FCI E3/S3 series. It comes in a red surface-mount enclosure and occupies two POTS (plain old telephone service) lines for primary and backup communications. The unit monitors line voltage, seizes the line if needed, sends centrally-station-formatted signals (Contact ID protocol) for alarms, troubles, supervisories and AC power loss, and provides LED status indicators for connectivity and fault conditions.

Key Features:

  • Dual Telephone-Line Support: Provides primary and backup line paths for reliable central station reporting.
  • Contact ID Protocol Compliance: Supports prevailing central-station reporting format for fire alarm communications.
  • Line Seizure Capability: Automatically seizes the local phone line to ensure prompt reporting over POTS.
  • Line-Voltage Monitoring: Detects loss or sag of the telephone line and reports as a trouble condition.
  • Compatible Panel Support: Designed to interface out-of-the-box with Notifier ONYX/INSPIRE and Gamewell-FCI E3/S3 panels.
  • LED Status Indicators: Front panel LEDs show Lost Panel Connection, Central Station Handshake Signal and Communication Failure.
  • Compact Surface Mount Enclosure: Housed in a red cabinet, external to the fire alarm panel, for ease of installation.
  • Comprehensive Event Reporting: Reports alarms, troubles, supervisory signals, NAC trouble, panel off-normal, and AC power loss.
  • UL/ETL and FCC Approvals: Electro-mechanical listing to UL 864 standard and FCC ID compliance for telecom interface.
  • Seismic Mounting-Capable: Accepts seismic mounting hardware for installation in IBC/IBC-zone locations when required.

The HON-DACT-DS DS Dialer delivers the required communication reliability and compatibility for monitored fire alarm installations.