Product Description P/N: C7061M1008
Description
The Honeywell C7061M1008 is a dynamic, self-checking ultraviolet (UV) flame detector designed to monitor the combustion process in large industrial gas and oil burners. Operating in conjunction with a primary burner management system, this sensor continuously scans for the UV radiation emitted by open flames. By utilizing a continuous mechanical shutter mechanism to verify its own operational integrity, the detector ensures the rapid and safe shutdown of fuel valves in the event of a dangerous flameout.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | HVAC Parts |
| Part Number | C7061M1008 |
| Subcategory | Flame Detectors |
| Sensor Type | Ultraviolet (UV) |
| Safety Feature | Dynamic Self-Checking (Mechanical Shutter) |
| Operating Voltage | 120 VAC, 50/60 Hz |
| System Compatibility | Honeywell Dynamic Burner Controls |
| Housing Material | Cast Aluminum |
| Mounting Connection | NPT Threaded Flange |
| Weight | 2.5 lbs |
Information About C7061M1008BCM-MS/TP
The C7061M1008 is an integral safety component within Honeywell’s comprehensive burner control architecture. It is engineered with a built-in oscillating shutter that briefly blocks the UV sensor every few seconds; this allows the connected programming control module to verify that the sensor tube has not short-circuited and is functioning correctly. Combustion engineers utilize this 120 VAC dynamic self-checking feature to comply with stringent industrial safety codes for continuously operating commercial boilers and heavy-duty industrial furnaces. The detector is housed in a rugged, cast-metal enclosure that protects the sensitive quartz viewing window and internal electronics from the extreme heat and vibration of the burner front.
Key Features:
● Dynamic Self-Checking: Incorporates a mechanical shutter that continuously verifies sensor integrity, preventing false positive flame readings due to internal short circuits.
● Ultraviolet Flame Detection: Highly sensitive to the specific UV radiation produced by gas and oil combustion, ensuring accurate flame discrimination.
● 120 VAC Operation: Runs seamlessly on standard industrial line voltage, integrating directly with compatible Honeywell dynamic programming controls.
● Rugged Cast-Metal Housing: Built with a heavy-duty exterior to endure the severe thermal conditions, industrial grime, and mechanical shock of burner operation.
● Field-Replaceable Sensor Tube: Designed with a removable UV sensing tube, allowing maintenance technicians to quickly service the unit without replacing the entire housing.
● Secure Mounting Flange: Features a standardized threaded connection to ensure proper alignment and a secure mechanical seal against the combustion chamber viewing port.
Description
The Honeywell C7061M1008 is a dynamic, self-checking ultraviolet (UV) flame detector designed to monitor the combustion process in large industrial gas and oil burners. Operating in conjunction with a primary burner management system, this sensor continuously scans for the UV radiation emitted by open flames. By utilizing a continuous mechanical shutter mechanism to verify its own operational integrity, the detector ensures the rapid and safe shutdown of fuel valves in the event of a dangerous flameout.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | HVAC Parts |
| Part Number | C7061M1008 |
| Subcategory | Flame Detectors |
| Sensor Type | Ultraviolet (UV) |
| Safety Feature | Dynamic Self-Checking (Mechanical Shutter) |
| Operating Voltage | 120 VAC, 50/60 Hz |
| System Compatibility | Honeywell Dynamic Burner Controls |
| Housing Material | Cast Aluminum |
| Mounting Connection | NPT Threaded Flange |
| Weight | 2.5 lbs |
Information About C7061M1008BCM-MS/TP
The C7061M1008 is an integral safety component within Honeywell’s comprehensive burner control architecture. It is engineered with a built-in oscillating shutter that briefly blocks the UV sensor every few seconds; this allows the connected programming control module to verify that the sensor tube has not short-circuited and is functioning correctly. Combustion engineers utilize this 120 VAC dynamic self-checking feature to comply with stringent industrial safety codes for continuously operating commercial boilers and heavy-duty industrial furnaces. The detector is housed in a rugged, cast-metal enclosure that protects the sensitive quartz viewing window and internal electronics from the extreme heat and vibration of the burner front.
Key Features:
● Dynamic Self-Checking: Incorporates a mechanical shutter that continuously verifies sensor integrity, preventing false positive flame readings due to internal short circuits.
● Ultraviolet Flame Detection: Highly sensitive to the specific UV radiation produced by gas and oil combustion, ensuring accurate flame discrimination.
● 120 VAC Operation: Runs seamlessly on standard industrial line voltage, integrating directly with compatible Honeywell dynamic programming controls.
● Rugged Cast-Metal Housing: Built with a heavy-duty exterior to endure the severe thermal conditions, industrial grime, and mechanical shock of burner operation.
● Field-Replaceable Sensor Tube: Designed with a removable UV sensing tube, allowing maintenance technicians to quickly service the unit without replacing the entire housing.
● Secure Mounting Flange: Features a standardized threaded connection to ensure proper alignment and a secure mechanical seal against the combustion chamber viewing port.