HS-NCM-W-2 | Notifier Network Communication Module
- Regular price
- $2,587.00
- Sale price
- $2,587.00
- Regular price
-
Couldn't load pickup availability
Do you need help?

Product Description P/N: HS-NCM-W-2
Description
The HS‑NCM‑W‑2 is part of Notifier’s High‑Speed Network Communications Module family, designed for seamless integration across Notifier fire alarm networks.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Notifier |
Category | Fire Safety |
Part Number | HS-NCM-W-2 |
Subcategory | Fire Alarm Control |
Type | High-Speed Network Communication Module |
Supported Medium | Twisted-pair wire |
Network Operation Modes | NFPA Style 4 (Class B) or NFPA Style 7 (Class A) |
Electrical Isolation | Transformer coupling between nodes |
Wiring Connection | Pluggable terminal wiring with strain relief |
Service Connector | Pluggable bypass connector to pass signal through if power is removed from a node |
Transmission Rate | 12 Mb |
Data Handling | Data regenerated at each node |
Network Ports | Two—simultaneous connection to fire alarm control panel and programming computer |
Software Support | Enables software/database upload/download over High-Speed NOTI•FIRE•NET™ |
Max. Distance Between Nodes | Up to 3,000 ft (914.4 m) point-to-point (varies with cable quality) |
Weight | 0.65 lbs |
Information About HS-NCM-W-2
The HS-NCM-W-2 is part of Notifier’s high-speed network communication solutions, engineered to provide reliable, isolated, and high-capacity data transfer across fire alarm control networks. Designed for use with twisted-pair wiring, this module supports NFPA Style 4 (Class B) and Style 7 (Class A) network configurations, ensuring flexibility in system topology. Operating at a 12 Mb transmission rate with data regeneration at each node, the HS-NCM-W-2 enables seamless integration into NOTI•FIRE•NET™ networks for both new and expanded installations. With dual network ports, transformer-coupled isolation, and up to 3,000 ft between nodes, it delivers robust communication performance for complex fire protection systems.
Key Features:
- Twisted-Pair Communication: Supports twisted-pair wire medium for versatile installation.
- Flexible Network Operation: Compatible with NFPA Style 4 (Class B) and Style 7 (Class A) wiring configurations.
- Electrical Isolation: Transformer coupling between nodes provides protection and signal integrity.
- Tool-Free Wiring: Pluggable terminal connections with strain relief for quick, secure installation.
- Service Connector: Passes network signal through even when module power is removed, maintaining communication integrity.
- High-Speed Transmission: Operates at 12 Mb with automatic data regeneration at each node for consistent performance.
- Dual Network Ports: Allows simultaneous connection to the fire alarm control panel and a programming computer.
- Programming Capability: Supports software/database upload and download over high-speed NOTI•FIRE•NET™.
- Long-Distance Support: Operates up to 3,000 ft (914.4 m) point-to-point, distance dependent on cable quality.
- Upgrade Path: Replaces the earlier HS-NCM-W model with enhanced speed and reliability.
The Notifier HS-NCM-W-2 delivers high-speed, reliable, and isolated network communication for large or distributed fire alarm systems. With its flexible configuration options, long-distance capability, and robust performance, it is an ideal choice for mission-critical installations requiring fast and dependable system connectivity.
Description
The HS‑NCM‑W‑2 is part of Notifier’s High‑Speed Network Communications Module family, designed for seamless integration across Notifier fire alarm networks.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Notifier |
Category | Fire Safety |
Part Number | HS-NCM-W-2 |
Subcategory | Fire Alarm Control |
Type | High-Speed Network Communication Module |
Supported Medium | Twisted-pair wire |
Network Operation Modes | NFPA Style 4 (Class B) or NFPA Style 7 (Class A) |
Electrical Isolation | Transformer coupling between nodes |
Wiring Connection | Pluggable terminal wiring with strain relief |
Service Connector | Pluggable bypass connector to pass signal through if power is removed from a node |
Transmission Rate | 12 Mb |
Data Handling | Data regenerated at each node |
Network Ports | Two—simultaneous connection to fire alarm control panel and programming computer |
Software Support | Enables software/database upload/download over High-Speed NOTI•FIRE•NET™ |
Max. Distance Between Nodes | Up to 3,000 ft (914.4 m) point-to-point (varies with cable quality) |
Weight | 0.65 lbs |
Information About HS-NCM-W-2
The HS-NCM-W-2 is part of Notifier’s high-speed network communication solutions, engineered to provide reliable, isolated, and high-capacity data transfer across fire alarm control networks. Designed for use with twisted-pair wiring, this module supports NFPA Style 4 (Class B) and Style 7 (Class A) network configurations, ensuring flexibility in system topology. Operating at a 12 Mb transmission rate with data regeneration at each node, the HS-NCM-W-2 enables seamless integration into NOTI•FIRE•NET™ networks for both new and expanded installations. With dual network ports, transformer-coupled isolation, and up to 3,000 ft between nodes, it delivers robust communication performance for complex fire protection systems.
Key Features:
- Twisted-Pair Communication: Supports twisted-pair wire medium for versatile installation.
- Flexible Network Operation: Compatible with NFPA Style 4 (Class B) and Style 7 (Class A) wiring configurations.
- Electrical Isolation: Transformer coupling between nodes provides protection and signal integrity.
- Tool-Free Wiring: Pluggable terminal connections with strain relief for quick, secure installation.
- Service Connector: Passes network signal through even when module power is removed, maintaining communication integrity.
- High-Speed Transmission: Operates at 12 Mb with automatic data regeneration at each node for consistent performance.
- Dual Network Ports: Allows simultaneous connection to the fire alarm control panel and a programming computer.
- Programming Capability: Supports software/database upload and download over high-speed NOTI•FIRE•NET™.
- Long-Distance Support: Operates up to 3,000 ft (914.4 m) point-to-point, distance dependent on cable quality.
- Upgrade Path: Replaces the earlier HS-NCM-W model with enhanced speed and reliability.
The Notifier HS-NCM-W-2 delivers high-speed, reliable, and isolated network communication for large or distributed fire alarm systems. With its flexible configuration options, long-distance capability, and robust performance, it is an ideal choice for mission-critical installations requiring fast and dependable system connectivity.