JGA36250 | Schneider Electric PowerPacT J-Frame 250A 3-Pole Thermal-Magnetic Circuit Breaker
- Regular price
- $1,455.00
- Sale price
- $1,455.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: JGA36250
Description
The JGA36250 from Schneider Electric is a PowerPacT J-Frame molded case circuit breaker engineered to provide dependable thermal-magnetic protection for distribution systems. Rated at 250 amps with a 3-pole configuration, it delivers effective protection against overloads and short-circuit conditions in industrial and commercial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | JGA36250 |
| Subcategory | Molded Case Circuit Breaker |
| Product Series | PowerPacT J |
| Rated Current | 250 A |
| Number of Poles | 3 |
| Trip Unit Technology | Thermal-Magnetic |
| Breaking Capacity Code | G |
| Interrupt Rating | 18 kA @ 600 VAC |
| Rated Operational Voltage | 600 VAC 50/60 Hz |
| Rated Insulation Voltage | 750 V |
| Impulse Withstand Voltage | 8 kV |
| Magnetic Hold Current | 1250 A |
| Magnetic Trip Current | 2500 A |
| Continuous Current Rating | 80% |
| Mounting Mode | I-Line Bracket |
| Electrical Connection | I-Line (Line), Lugs (Load) |
| Wire Size | AWG 3/0–350 kcmil Copper / Aluminum |
| Phase Connection | ABC |
| Height | 7.52 in (191 mm) |
| Width | 4.09 in (104 mm) |
| Depth | 3.39 in (86 mm) |
| Weight | 5.29 lb (2.4 kg) |
Information About JGA36250
The JGA36250 is part of the Schneider Electric PowerPacT J series, designed for high-performance power distribution applications requiring robust protection and compact construction. It utilizes dual-break rotating contacts to reduce peak let-through current during fault conditions, improving system reliability and breaker longevity. This model is configured for I-Line mounting on the line side with mechanical lugs on the load side, supporting efficient installation and secure connections. It is commonly installed in switchboards and panelboards where high current capacity and standardized PowerPacT accessories are required.
Key Features
- Thermal-magnetic trip unit: Provides coordinated protection against overloads and short circuits.
- PowerPacT J-Frame construction: Designed for demanding industrial and commercial distribution systems.
- Dual-break rotating contacts: Minimizes peak current during short-circuit interruption.
- 3-pole configuration: Supports three-phase power distribution.
- Push-to-trip button: Enables manual tripping without exposure to live parts.
- I-Line mounting capability: Allows fast installation and removal in compatible systems.
- High interrupting capacity: Rated at 18 kA at 600 VAC for reliable fault protection.
The JGA36250 delivers the reliability and precision required for high-current three-phase distribution circuit protection.
Description
The JGA36250 from Schneider Electric is a PowerPacT J-Frame molded case circuit breaker engineered to provide dependable thermal-magnetic protection for distribution systems. Rated at 250 amps with a 3-pole configuration, it delivers effective protection against overloads and short-circuit conditions in industrial and commercial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | JGA36250 |
| Subcategory | Molded Case Circuit Breaker |
| Product Series | PowerPacT J |
| Rated Current | 250 A |
| Number of Poles | 3 |
| Trip Unit Technology | Thermal-Magnetic |
| Breaking Capacity Code | G |
| Interrupt Rating | 18 kA @ 600 VAC |
| Rated Operational Voltage | 600 VAC 50/60 Hz |
| Rated Insulation Voltage | 750 V |
| Impulse Withstand Voltage | 8 kV |
| Magnetic Hold Current | 1250 A |
| Magnetic Trip Current | 2500 A |
| Continuous Current Rating | 80% |
| Mounting Mode | I-Line Bracket |
| Electrical Connection | I-Line (Line), Lugs (Load) |
| Wire Size | AWG 3/0–350 kcmil Copper / Aluminum |
| Phase Connection | ABC |
| Height | 7.52 in (191 mm) |
| Width | 4.09 in (104 mm) |
| Depth | 3.39 in (86 mm) |
| Weight | 5.29 lb (2.4 kg) |
Information About JGA36250
The JGA36250 is part of the Schneider Electric PowerPacT J series, designed for high-performance power distribution applications requiring robust protection and compact construction. It utilizes dual-break rotating contacts to reduce peak let-through current during fault conditions, improving system reliability and breaker longevity. This model is configured for I-Line mounting on the line side with mechanical lugs on the load side, supporting efficient installation and secure connections. It is commonly installed in switchboards and panelboards where high current capacity and standardized PowerPacT accessories are required.
Key Features
- Thermal-magnetic trip unit: Provides coordinated protection against overloads and short circuits.
- PowerPacT J-Frame construction: Designed for demanding industrial and commercial distribution systems.
- Dual-break rotating contacts: Minimizes peak current during short-circuit interruption.
- 3-pole configuration: Supports three-phase power distribution.
- Push-to-trip button: Enables manual tripping without exposure to live parts.
- I-Line mounting capability: Allows fast installation and removal in compatible systems.
- High interrupting capacity: Rated at 18 kA at 600 VAC for reliable fault protection.
The JGA36250 delivers the reliability and precision required for high-current three-phase distribution circuit protection.