Description
The Kidde KI-HDT is a handheld diagnostic tool designed for initializing, testing, and troubleshooting intelligent Signaling Line Circuits (SLC) used in Kidde fire alarm systems. The KI-HDT provides technicians with a portable solution for commissioning new installations, diagnosing existing loops, and verifying connected devices through an intuitive touchscreen interface and integrated diagnostic functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Kidde |
| Category | Test Equipment |
| Part Number | KI-HDT |
| Subcategory | Handheld Diagnostic Tool |
| Product Type | Standalone Handheld Diagnostic Tool |
| Application | Intelligent Fire Alarm Signaling Line Circuit (SLC) Diagnostics |
| Power Source | Rechargeable Lithium-Ion Battery |
| Charging Interface | USB 2.0 / Micro-USB |
| Display | Touchscreen Graphical User Interface |
| Loop Functions | Initialize, Restore, Map Analysis, Loop Diagnostics |
| Diagnostic Functions | Wiring Fault Detection, Ground Fault Detection, Dirty Detector Analysis |
| PC Compatibility | Windows 7 and Windows 10 Diagnostic Software |
| Communication Ports | USB Flash Drive Port, Micro-USB Port |
| Typical Use | Installation, Commissioning, Maintenance, Troubleshooting |
| Included Accessories | USB Flash Drive, USB Cable, AC Adapter, Terminal Blocks, Lithium-Ion Battery |
| Dimensions | 5.25 × 3.25 × 1.75 in (133.3 × 82.5 × 44.5 mm) |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Weight | 0.7 kg (1.54 lbs) |
Information About KI-HDT
The KI-HDT is a standalone, battery-operated handheld diagnostic tool developed for Kidde intelligent fire alarm systems utilizing Signaling Line Circuits. It enables installers and service personnel to initialize SLC loops, analyze device mapping, detect wiring faults, evaluate detector contamination levels, and program device addresses without requiring connection to a fire alarm control panel. The unit features a rechargeable lithium-ion battery, a color touchscreen display, USB and Micro-USB interfaces, and PC-compatible software for report generation and data management. Designed for field service applications, the KI-HDT simplifies installation, maintenance, commissioning, and troubleshooting of compatible Kidde intelligent detectors and modules.
Key Features:
- Standalone Operation: Functions independently using an internal rechargeable lithium-ion battery.
- SLC Initialization: Identifies and initializes all devices connected to an intelligent Signaling Line Circuit.
- Advanced Diagnostics: Performs comprehensive loop analysis to identify wiring faults and communication issues.
- Device Address Programming: Programs addresses for compatible intelligent detectors and modules.
- Detector Maintenance Analysis: Evaluates detector contamination levels to identify units requiring cleaning.
- Touchscreen Interface: Bright graphical display provides intuitive navigation and real-time diagnostic information.
- USB Connectivity: Supports PC software, firmware updates, report generation, and data transfer through USB interfaces.
- Portable Field Tool: Compact handheld design simplifies commissioning, maintenance, and service operations.
The KI-HDT delivers the reliability and precision required for commissioning, troubleshooting, and maintaining intelligent fire alarm Signaling Line Circuits.
Description
The Kidde KI-HDT is a handheld diagnostic tool designed for initializing, testing, and troubleshooting intelligent Signaling Line Circuits (SLC) used in Kidde fire alarm systems. The KI-HDT provides technicians with a portable solution for commissioning new installations, diagnosing existing loops, and verifying connected devices through an intuitive touchscreen interface and integrated diagnostic functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Kidde |
| Category | Test Equipment |
| Part Number | KI-HDT |
| Subcategory | Handheld Diagnostic Tool |
| Product Type | Standalone Handheld Diagnostic Tool |
| Application | Intelligent Fire Alarm Signaling Line Circuit (SLC) Diagnostics |
| Power Source | Rechargeable Lithium-Ion Battery |
| Charging Interface | USB 2.0 / Micro-USB |
| Display | Touchscreen Graphical User Interface |
| Loop Functions | Initialize, Restore, Map Analysis, Loop Diagnostics |
| Diagnostic Functions | Wiring Fault Detection, Ground Fault Detection, Dirty Detector Analysis |
| PC Compatibility | Windows 7 and Windows 10 Diagnostic Software |
| Communication Ports | USB Flash Drive Port, Micro-USB Port |
| Typical Use | Installation, Commissioning, Maintenance, Troubleshooting |
| Included Accessories | USB Flash Drive, USB Cable, AC Adapter, Terminal Blocks, Lithium-Ion Battery |
| Dimensions | 5.25 × 3.25 × 1.75 in (133.3 × 82.5 × 44.5 mm) |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Weight | 0.7 kg (1.54 lbs) |
Information About KI-HDT
The KI-HDT is a standalone, battery-operated handheld diagnostic tool developed for Kidde intelligent fire alarm systems utilizing Signaling Line Circuits. It enables installers and service personnel to initialize SLC loops, analyze device mapping, detect wiring faults, evaluate detector contamination levels, and program device addresses without requiring connection to a fire alarm control panel. The unit features a rechargeable lithium-ion battery, a color touchscreen display, USB and Micro-USB interfaces, and PC-compatible software for report generation and data management. Designed for field service applications, the KI-HDT simplifies installation, maintenance, commissioning, and troubleshooting of compatible Kidde intelligent detectors and modules.
Key Features:
- Standalone Operation: Functions independently using an internal rechargeable lithium-ion battery.
- SLC Initialization: Identifies and initializes all devices connected to an intelligent Signaling Line Circuit.
- Advanced Diagnostics: Performs comprehensive loop analysis to identify wiring faults and communication issues.
- Device Address Programming: Programs addresses for compatible intelligent detectors and modules.
- Detector Maintenance Analysis: Evaluates detector contamination levels to identify units requiring cleaning.
- Touchscreen Interface: Bright graphical display provides intuitive navigation and real-time diagnostic information.
- USB Connectivity: Supports PC software, firmware updates, report generation, and data transfer through USB interfaces.
- Portable Field Tool: Compact handheld design simplifies commissioning, maintenance, and service operations.
The KI-HDT delivers the reliability and precision required for commissioning, troubleshooting, and maintaining intelligent fire alarm Signaling Line Circuits.