MAMAC Systems VA-921-VDC-7 Wall-Mount Humidity Sensor
- Regular price
- $247.00
- Sale price
- $247.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: VA-921-VDC-7
Description
The MAMAC Systems VA-921-VDC-7 is a wall-mounted humidity sensor designed to monitor relative humidity in HVAC and building automation systems. It uses a resistive polymer sensing element to provide humidity measurements for ventilation control, indoor air-quality monitoring, and environmental regulation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | MAMAC Systems |
| Category | HVAC & Building Automation |
| Part Number | VA-921-VDC-7 |
| Subcategory | Humidity Sensors |
| Series | VA-921 |
| Sensor Type | Relative Humidity Sensor |
| Measurement Range | 0–100% RH |
| Accuracy | ±3% RH (30–70% RH range) |
| Sensing Element | Resistive Polymer |
| Output Signal | 0–5 VDC / 0–10 VDC, Field Selectable |
| Mounting | Wall Mount |
| Temperature Compensation | -30°F to 130°F (-35°C to 55°C) |
| Application | HVAC, Building Automation, Environmental Monitoring |
| Weight | 0.16 lb |
Information About VA-921-VDC-7
The VA-921-VDC-7 belongs to the MAMAC Systems VA-921 Series of wall-mounted humidity sensors. It measures relative humidity across a 0–100% RH range, with an accuracy of approximately ±3% over the 30–70% RH range. The sensor uses a resistive polymer sensing element and provides an analog voltage output for integration with compatible HVAC controllers. Its wall-mount design makes it suitable for commercial buildings, environmental chambers, and industrial monitoring applications.
Key Features:
-
Relative Humidity Measurement: Monitors humidity across a 0–100% RH measurement range for indoor environmental control.
-
Resistive Polymer Sensing: Uses a polymer sensing element designed to provide responsive humidity detection.
-
Measurement Accuracy: Provides approximately ±3% RH accuracy over the 30–70% RH range.
-
Analog Voltage Output: Offers field-selectable 0–5 VDC or 0–10 VDC output options, according to the available product listing.
-
Wall-Mount Installation: Designed for convenient installation on interior walls in HVAC and building automation environments.
-
Temperature Compensation: Designed to operate across a compensated temperature range of approximately -30°F to 130°F.
-
Moisture Protection: Features protected electronics and sensing components intended for humid operating environments.
-
HVAC Integration: Suitable for humidity monitoring, ventilation control, and environmental regulation systems.
The VA-921-VDC-7 provides reliable relative humidity monitoring and analog signal integration for building automation and environmental control applications.
Description
The MAMAC Systems VA-921-VDC-7 is a wall-mounted humidity sensor designed to monitor relative humidity in HVAC and building automation systems. It uses a resistive polymer sensing element to provide humidity measurements for ventilation control, indoor air-quality monitoring, and environmental regulation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | MAMAC Systems |
| Category | HVAC & Building Automation |
| Part Number | VA-921-VDC-7 |
| Subcategory | Humidity Sensors |
| Series | VA-921 |
| Sensor Type | Relative Humidity Sensor |
| Measurement Range | 0–100% RH |
| Accuracy | ±3% RH (30–70% RH range) |
| Sensing Element | Resistive Polymer |
| Output Signal | 0–5 VDC / 0–10 VDC, Field Selectable |
| Mounting | Wall Mount |
| Temperature Compensation | -30°F to 130°F (-35°C to 55°C) |
| Application | HVAC, Building Automation, Environmental Monitoring |
| Weight | 0.16 lb |
Information About VA-921-VDC-7
The VA-921-VDC-7 belongs to the MAMAC Systems VA-921 Series of wall-mounted humidity sensors. It measures relative humidity across a 0–100% RH range, with an accuracy of approximately ±3% over the 30–70% RH range. The sensor uses a resistive polymer sensing element and provides an analog voltage output for integration with compatible HVAC controllers. Its wall-mount design makes it suitable for commercial buildings, environmental chambers, and industrial monitoring applications.
Key Features:
-
Relative Humidity Measurement: Monitors humidity across a 0–100% RH measurement range for indoor environmental control.
-
Resistive Polymer Sensing: Uses a polymer sensing element designed to provide responsive humidity detection.
-
Measurement Accuracy: Provides approximately ±3% RH accuracy over the 30–70% RH range.
-
Analog Voltage Output: Offers field-selectable 0–5 VDC or 0–10 VDC output options, according to the available product listing.
-
Wall-Mount Installation: Designed for convenient installation on interior walls in HVAC and building automation environments.
-
Temperature Compensation: Designed to operate across a compensated temperature range of approximately -30°F to 130°F.
-
Moisture Protection: Features protected electronics and sensing components intended for humid operating environments.
-
HVAC Integration: Suitable for humidity monitoring, ventilation control, and environmental regulation systems.
The VA-921-VDC-7 provides reliable relative humidity monitoring and analog signal integration for building automation and environmental control applications.