MRP-2002 | Fire-Lite Six-Zone Agent Release Control Panel
- Regular price
- $1,999.00
- Sale price
- $1,999.00
- Regular price
-
Couldn't load pickup availability
Do you need help?

Product Description P/N: MRP-2002
Description
The Fire-Lite MRP-2002 is a six-zone fire alarm control panel (FACP) designed for single and dual hazard agent releasing applications. It provides reliable fire detection, signaling, and suppression control in commercial, industrial, and institutional facilities. With flexible compatibility and integrated programming options, the MRP-2002 ensures dependable performance in agent-based releasing systems.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Fire-Lite |
Category | Fire Safety |
Part Number | MRP-2002 |
Subcategory | Agent Release Control Panel |
Zones | Six Style B (Class B) or Style D (Class A) circuits |
Outputs | Four programmable Style Y (Class B) circuits |
Relays | Three Form-C (Alarm, Trouble, Supervisory) |
Compatible Detectors | System Sensor® i3 two-wire and four-wire detectors |
Special Functions | Adjustable pre-discharge, discharge, and waterflow timers |
Cross-Zone Capability | Double-interlock operation supported |
Power Input | 110/120 VAC (MRP-2002) or 220/240 VAC (MRP-2002E) |
Built-In Programmer | Yes |
NAC Synchronization | System Sensor®, Wheelock®, Gentex®, Faraday®, Amseco® |
Supervision | AC power, battery, charger, and wiring supervision |
Compliance | Meets IBC seismic requirements |
Dimensions | 8.50 × 22.50 × 20.00 in |
Weight | 24.05 lbs |
Information About MRP-2002
The MRP-2002 is a member of Fire-Lite’s agent release control panel series, purpose-built for specialized fire suppression environments. It supports six initiating device circuits that can be configured as Style B (Class B) or Style D (Class A) with optional modules. The panel integrates with System Sensor® i3 smoke detectors, enabling maintenance trouble and freeze condition monitoring. Additionally, it accommodates a wide range of conventional input devices including pull stations, waterflow detectors, and tamper switches. With built-in NAC synchronization and customizable timers, the MRP-2002 simplifies setup while maintaining compliance with industry codes and standards.
Key Features
- Six-Zone Capacity: Supports up to six Style B or Style D initiating device circuits.
- Programmable Outputs: Four outputs configurable as notification appliance circuits or releasing circuits.
- Dual Hazard Operation: Enables independent control for two separate hazards.
- Integrated Timers: Adjustable pre-discharge, discharge, and waterflow delay timers enhance flexibility.
- Cross-Zone Functionality: Supports double-interlock operation for higher safety assurance.
- Device Compatibility: Works with System Sensor® i3 smoke detectors and a wide range of input devices.
- Built-In Synchronization: NAC synchronization for System Sensor®, Wheelock®, Gentex®, Faraday®, and Amseco® devices.
- Onboard Relays: Includes three programmable Form-C relays for alarm, trouble, and supervisory outputs.
The MRP-2002 delivers the reliability and precision required for agent-based fire detection and releasing system applications.
Description
The Fire-Lite MRP-2002 is a six-zone fire alarm control panel (FACP) designed for single and dual hazard agent releasing applications. It provides reliable fire detection, signaling, and suppression control in commercial, industrial, and institutional facilities. With flexible compatibility and integrated programming options, the MRP-2002 ensures dependable performance in agent-based releasing systems.
Technical Specifications
Condition | New/Never Used Surplus |
Brand | Fire-Lite |
Category | Fire Safety |
Part Number | MRP-2002 |
Subcategory | Agent Release Control Panel |
Zones | Six Style B (Class B) or Style D (Class A) circuits |
Outputs | Four programmable Style Y (Class B) circuits |
Relays | Three Form-C (Alarm, Trouble, Supervisory) |
Compatible Detectors | System Sensor® i3 two-wire and four-wire detectors |
Special Functions | Adjustable pre-discharge, discharge, and waterflow timers |
Cross-Zone Capability | Double-interlock operation supported |
Power Input | 110/120 VAC (MRP-2002) or 220/240 VAC (MRP-2002E) |
Built-In Programmer | Yes |
NAC Synchronization | System Sensor®, Wheelock®, Gentex®, Faraday®, Amseco® |
Supervision | AC power, battery, charger, and wiring supervision |
Compliance | Meets IBC seismic requirements |
Dimensions | 8.50 × 22.50 × 20.00 in |
Weight | 24.05 lbs |
Information About MRP-2002
The MRP-2002 is a member of Fire-Lite’s agent release control panel series, purpose-built for specialized fire suppression environments. It supports six initiating device circuits that can be configured as Style B (Class B) or Style D (Class A) with optional modules. The panel integrates with System Sensor® i3 smoke detectors, enabling maintenance trouble and freeze condition monitoring. Additionally, it accommodates a wide range of conventional input devices including pull stations, waterflow detectors, and tamper switches. With built-in NAC synchronization and customizable timers, the MRP-2002 simplifies setup while maintaining compliance with industry codes and standards.
Key Features
- Six-Zone Capacity: Supports up to six Style B or Style D initiating device circuits.
- Programmable Outputs: Four outputs configurable as notification appliance circuits or releasing circuits.
- Dual Hazard Operation: Enables independent control for two separate hazards.
- Integrated Timers: Adjustable pre-discharge, discharge, and waterflow delay timers enhance flexibility.
- Cross-Zone Functionality: Supports double-interlock operation for higher safety assurance.
- Device Compatibility: Works with System Sensor® i3 smoke detectors and a wide range of input devices.
- Built-In Synchronization: NAC synchronization for System Sensor®, Wheelock®, Gentex®, Faraday®, and Amseco® devices.
- Onboard Relays: Includes three programmable Form-C relays for alarm, trouble, and supervisory outputs.
The MRP-2002 delivers the reliability and precision required for agent-based fire detection and releasing system applications.