MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module
MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module
MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module
    MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module
MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module

MVI69-MNET | Allen-Bradley ProSoft Technology Modbus TCP/IP Client/Server Communication Module

Part #: MVI69-MNET Manufactured by: Allen-Bradley
Regular price
$2,117.00
Sale price
$2,117.00
Regular price
4 in Stock
Condition: New – Open box
Shipping calculated at checkout.
Product Overview
The ProSoft MVI69-MNET Modbus TCP/IP Communication Module has 1 Slot and 5000 max. Registers. It also has Ladder Logic Dat...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 12:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: MVI69-MNET
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro is Not an authorized distributor for Allen-Bradley
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: MVI69-MNET

Description / Specifications

Description 

The ProSoft MVI69-MNET is a Modbus TCP/IP communication module designed for CompactLogix and MicroLogix platforms, enabling seamless integration with Modbus-compatible devices. This single-slot module provides both client and server functionality, allowing controllers to exchange data with a wide range of Modbus TCP/IP networks. It is widely used in industrial automation systems where reliable and high-speed interoperability between Rockwell Automation controllers and third-party devices is required.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand ProSoft Technology
Category Communication Modules
Part Number MVI69-MNET
Subcategory Modbus TCP/IP Communication Module
Compatible Controllers CompactLogix, MicroLogix 1500 LRP (excludes 1769-QBFC1B, 1769-L16x, 1769-L18x)
Module Type Single-slot 1769 backplane module
Client Connections Up to 5
Server Connections Up to 5 (Modbus TCP/IP Server Port 502)
Command Capacity Up to 100 Client commands
Register Space 5000 × 16-bit registers
Ethernet Interface 10/100 Base-T auto-negotiating
Data Mapping Start Modbus register 40001
Operating Temperature 0…60°C (32…140°F)
Storage Temperature –40…85°C (–40…185°F)
Humidity 5–95% non-condensing
Current Load 800 mA @ 5 VDC
CFG Port RJ45 (DB-9 adapter supplied), RS-232 only
Application Port 10/100 Ethernet with isolation
LED Indicators Power, module, CFG, app port, Ethernet activity, error
Included Accessories RJ45-to-DB9 cable, 6-ft RS-232 configuration cable
Agency Approvals CE, UL, cUL, and other industrial certifications

  

 

Information About MVI69-MNET

The MVI69-MNET module is engineered as a 1769 backplane-compatible device that acts as an I/O module, giving it direct access to the processor’s memory for fast data exchange. It supports up to 5000 registers through block-transfer mechanisms, ensuring efficient communication between the PLC and external devices. The module can function as a Modbus TCP/IP Client or Server, handling multiple simultaneous connections and up to 100 client commands directed at one or more target servers. Configurable through text-based configuration files and supported by sample ladder logic, it simplifies integration into diverse network architectures. With an operating range of 0–60°C and robust Ethernet isolation, it is suitable for demanding industrial environments where stable, secure Modbus connectivity is essential.

Key Features:

  • Dual Modbus Roles: Supports both Modbus TCP/IP Client and Server functions for maximum integration flexibility.
  • High Register Capacity: Handles up to 5000 registers for large data exchange requirements between PLC and Modbus devices.
  • 1769 Backplane Compatible: Single-slot design works seamlessly with CompactLogix and MicroLogix 1500 LRP systems.
  • Flexible Connection Support: Allows multiple server connections and up to five client links simultaneously.
  • Command Handling: Supports up to 100 active Modbus client commands directed to one or more devices.
  • 10/100 Mbps Ethernet Interface: Provides reliable, auto-negotiating Ethernet connectivity with broadcast storm resilience.
  • User-Configurable Memory: Allows custom data mapping and memory allocation for specialized applications.
  • Floating-Point Support: Compatible with Enron, Daniels, and various extended floating-point formats.
  • Robust Diagnostics: Offers port status, activity monitoring, error codes, and communication counters.
  • Easy Configuration: Uses text-based configuration files and comes with sample ladder logic to accelerate deployment.

The MVI69-MNET delivers the reliability and performance required for Modbus TCP/IP integration in modern industrial control systems.

Frequently Asked Questions about MVI69-MNET
Question: What is the primary function of the MVI69-MNET module?
Date Update:05/06/2025
Answer:

The MVI69-MNET module serves as a bridge between Rockwell Automation's CompactLogix or MicroLogix 1500 controllers and Modbus TCP/IP networks. It allows these controllers to communicate with Modbus TCP/IP-compatible devices, facilitating data exchange and integration within industrial automation systems.

Question: Which controllers are compatible with the MVI69-MNET module?
Date Update:05/06/2025
Answer:

The MVI69-MNET module is designed for use with:

  • CompactLogix processors
  • MicroLogix 1500 LRP processors

Note: Compatibility may vary based on specific processor models and firmware versions. It's essential to consult the module's user manual for detailed compatibility information.

Question: What is the difference between the MVI69-MNET and MVI69-MCM modules?
Date Update:05/06/2025
Answer:
  • MVI69-MNET: Supports Modbus TCP/IP communication over Ethernet networks.
  • MVI69-MCM: Supports Modbus RTU/ASCII communication over serial connections (RS-232, RS-422, RS-485).

Choose the module that aligns with your network's communication protocol requirements.

Question: How do I update the firmware of the MVI69-MNET module?
Date Update:05/06/2025
Answer:

Firmware updates can be performed using the ProSoft Configuration Builder (PCB) software. Connect to the module via the serial debug port and follow the instructions provided in the user manual to complete the firmware update process.

Question: What should I do if I encounter issues downloading the configuration to the MVI69-MNET module?
Date Update:05/06/2025
Answer:

If you experience difficulties downloading the configuration:

  • Ensure that the correct COM port is selected in the PCB software.
  • Verify that the serial cable is properly connected to the module's debug port.
  • Check for any firewall or antivirus settings that may be blocking communication.
IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The ProSoft MVI69-MNET is a Modbus TCP/IP communication module designed for CompactLogix and MicroLogix platforms, enabling seamless integration with Modbus-compatible devices. This single-slot module provides both client and server functionality, allowing controllers to exchange data with a wide range of Modbus TCP/IP networks. It is widely used in industrial automation systems where reliable and high-speed interoperability between Rockwell Automation controllers and third-party devices is required.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand ProSoft Technology
Category Communication Modules
Part Number MVI69-MNET
Subcategory Modbus TCP/IP Communication Module
Compatible Controllers CompactLogix, MicroLogix 1500 LRP (excludes 1769-QBFC1B, 1769-L16x, 1769-L18x)
Module Type Single-slot 1769 backplane module
Client Connections Up to 5
Server Connections Up to 5 (Modbus TCP/IP Server Port 502)
Command Capacity Up to 100 Client commands
Register Space 5000 × 16-bit registers
Ethernet Interface 10/100 Base-T auto-negotiating
Data Mapping Start Modbus register 40001
Operating Temperature 0…60°C (32…140°F)
Storage Temperature –40…85°C (–40…185°F)
Humidity 5–95% non-condensing
Current Load 800 mA @ 5 VDC
CFG Port RJ45 (DB-9 adapter supplied), RS-232 only
Application Port 10/100 Ethernet with isolation
LED Indicators Power, module, CFG, app port, Ethernet activity, error
Included Accessories RJ45-to-DB9 cable, 6-ft RS-232 configuration cable
Agency Approvals CE, UL, cUL, and other industrial certifications

  

 

Information About MVI69-MNET

The MVI69-MNET module is engineered as a 1769 backplane-compatible device that acts as an I/O module, giving it direct access to the processor’s memory for fast data exchange. It supports up to 5000 registers through block-transfer mechanisms, ensuring efficient communication between the PLC and external devices. The module can function as a Modbus TCP/IP Client or Server, handling multiple simultaneous connections and up to 100 client commands directed at one or more target servers. Configurable through text-based configuration files and supported by sample ladder logic, it simplifies integration into diverse network architectures. With an operating range of 0–60°C and robust Ethernet isolation, it is suitable for demanding industrial environments where stable, secure Modbus connectivity is essential.

Key Features:

  • Dual Modbus Roles: Supports both Modbus TCP/IP Client and Server functions for maximum integration flexibility.
  • High Register Capacity: Handles up to 5000 registers for large data exchange requirements between PLC and Modbus devices.
  • 1769 Backplane Compatible: Single-slot design works seamlessly with CompactLogix and MicroLogix 1500 LRP systems.
  • Flexible Connection Support: Allows multiple server connections and up to five client links simultaneously.
  • Command Handling: Supports up to 100 active Modbus client commands directed to one or more devices.
  • 10/100 Mbps Ethernet Interface: Provides reliable, auto-negotiating Ethernet connectivity with broadcast storm resilience.
  • User-Configurable Memory: Allows custom data mapping and memory allocation for specialized applications.
  • Floating-Point Support: Compatible with Enron, Daniels, and various extended floating-point formats.
  • Robust Diagnostics: Offers port status, activity monitoring, error codes, and communication counters.
  • Easy Configuration: Uses text-based configuration files and comes with sample ladder logic to accelerate deployment.

The MVI69-MNET delivers the reliability and performance required for Modbus TCP/IP integration in modern industrial control systems.

Check Out These Related Products