Product Description P/N: MVI69-MNET
Description
The ProSoft MVI69-MNET is a Modbus TCP/IP communication module designed for CompactLogix and MicroLogix platforms, enabling seamless integration with Modbus-compatible devices. This single-slot module provides both client and server functionality, allowing controllers to exchange data with a wide range of Modbus TCP/IP networks. It is widely used in industrial automation systems where reliable and high-speed interoperability between Rockwell Automation controllers and third-party devices is required.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | ProSoft Technology |
| Category | Communication Modules |
| Part Number | MVI69-MNET |
| Subcategory | Modbus TCP/IP Communication Module |
| Compatible Controllers | CompactLogix, MicroLogix 1500 LRP (excludes 1769-QBFC1B, 1769-L16x, 1769-L18x) |
| Module Type | Single-slot 1769 backplane module |
| Client Connections | Up to 5 |
| Server Connections | Up to 5 (Modbus TCP/IP Server Port 502) |
| Command Capacity | Up to 100 Client commands |
| Register Space | 5000 × 16-bit registers |
| Ethernet Interface | 10/100 Base-T auto-negotiating |
| Data Mapping Start | Modbus register 40001 |
| Operating Temperature | 0…60°C (32…140°F) |
| Storage Temperature | –40…85°C (–40…185°F) |
| Humidity | 5–95% non-condensing |
| Current Load | 800 mA @ 5 VDC |
| CFG Port | RJ45 (DB-9 adapter supplied), RS-232 only |
| Application Port | 10/100 Ethernet with isolation |
| LED Indicators | Power, module, CFG, app port, Ethernet activity, error |
| Included Accessories | RJ45-to-DB9 cable, 6-ft RS-232 configuration cable |
| Agency Approvals | CE, UL, cUL, and other industrial certifications |
Information About MVI69-MNET
The MVI69-MNET module is engineered as a 1769 backplane-compatible device that acts as an I/O module, giving it direct access to the processor’s memory for fast data exchange. It supports up to 5000 registers through block-transfer mechanisms, ensuring efficient communication between the PLC and external devices. The module can function as a Modbus TCP/IP Client or Server, handling multiple simultaneous connections and up to 100 client commands directed at one or more target servers. Configurable through text-based configuration files and supported by sample ladder logic, it simplifies integration into diverse network architectures. With an operating range of 0–60°C and robust Ethernet isolation, it is suitable for demanding industrial environments where stable, secure Modbus connectivity is essential.
Key Features:
- Dual Modbus Roles: Supports both Modbus TCP/IP Client and Server functions for maximum integration flexibility.
- High Register Capacity: Handles up to 5000 registers for large data exchange requirements between PLC and Modbus devices.
- 1769 Backplane Compatible: Single-slot design works seamlessly with CompactLogix and MicroLogix 1500 LRP systems.
- Flexible Connection Support: Allows multiple server connections and up to five client links simultaneously.
- Command Handling: Supports up to 100 active Modbus client commands directed to one or more devices.
- 10/100 Mbps Ethernet Interface: Provides reliable, auto-negotiating Ethernet connectivity with broadcast storm resilience.
- User-Configurable Memory: Allows custom data mapping and memory allocation for specialized applications.
- Floating-Point Support: Compatible with Enron, Daniels, and various extended floating-point formats.
- Robust Diagnostics: Offers port status, activity monitoring, error codes, and communication counters.
- Easy Configuration: Uses text-based configuration files and comes with sample ladder logic to accelerate deployment.
The MVI69-MNET delivers the reliability and performance required for Modbus TCP/IP integration in modern industrial control systems.
Description
The ProSoft MVI69-MNET is a Modbus TCP/IP communication module designed for CompactLogix and MicroLogix platforms, enabling seamless integration with Modbus-compatible devices. This single-slot module provides both client and server functionality, allowing controllers to exchange data with a wide range of Modbus TCP/IP networks. It is widely used in industrial automation systems where reliable and high-speed interoperability between Rockwell Automation controllers and third-party devices is required.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | ProSoft Technology |
| Category | Communication Modules |
| Part Number | MVI69-MNET |
| Subcategory | Modbus TCP/IP Communication Module |
| Compatible Controllers | CompactLogix, MicroLogix 1500 LRP (excludes 1769-QBFC1B, 1769-L16x, 1769-L18x) |
| Module Type | Single-slot 1769 backplane module |
| Client Connections | Up to 5 |
| Server Connections | Up to 5 (Modbus TCP/IP Server Port 502) |
| Command Capacity | Up to 100 Client commands |
| Register Space | 5000 × 16-bit registers |
| Ethernet Interface | 10/100 Base-T auto-negotiating |
| Data Mapping Start | Modbus register 40001 |
| Operating Temperature | 0…60°C (32…140°F) |
| Storage Temperature | –40…85°C (–40…185°F) |
| Humidity | 5–95% non-condensing |
| Current Load | 800 mA @ 5 VDC |
| CFG Port | RJ45 (DB-9 adapter supplied), RS-232 only |
| Application Port | 10/100 Ethernet with isolation |
| LED Indicators | Power, module, CFG, app port, Ethernet activity, error |
| Included Accessories | RJ45-to-DB9 cable, 6-ft RS-232 configuration cable |
| Agency Approvals | CE, UL, cUL, and other industrial certifications |
Information About MVI69-MNET
The MVI69-MNET module is engineered as a 1769 backplane-compatible device that acts as an I/O module, giving it direct access to the processor’s memory for fast data exchange. It supports up to 5000 registers through block-transfer mechanisms, ensuring efficient communication between the PLC and external devices. The module can function as a Modbus TCP/IP Client or Server, handling multiple simultaneous connections and up to 100 client commands directed at one or more target servers. Configurable through text-based configuration files and supported by sample ladder logic, it simplifies integration into diverse network architectures. With an operating range of 0–60°C and robust Ethernet isolation, it is suitable for demanding industrial environments where stable, secure Modbus connectivity is essential.
Key Features:
- Dual Modbus Roles: Supports both Modbus TCP/IP Client and Server functions for maximum integration flexibility.
- High Register Capacity: Handles up to 5000 registers for large data exchange requirements between PLC and Modbus devices.
- 1769 Backplane Compatible: Single-slot design works seamlessly with CompactLogix and MicroLogix 1500 LRP systems.
- Flexible Connection Support: Allows multiple server connections and up to five client links simultaneously.
- Command Handling: Supports up to 100 active Modbus client commands directed to one or more devices.
- 10/100 Mbps Ethernet Interface: Provides reliable, auto-negotiating Ethernet connectivity with broadcast storm resilience.
- User-Configurable Memory: Allows custom data mapping and memory allocation for specialized applications.
- Floating-Point Support: Compatible with Enron, Daniels, and various extended floating-point formats.
- Robust Diagnostics: Offers port status, activity monitoring, error codes, and communication counters.
- Easy Configuration: Uses text-based configuration files and comes with sample ladder logic to accelerate deployment.
The MVI69-MNET delivers the reliability and performance required for Modbus TCP/IP integration in modern industrial control systems.