Product Description P/N: cDAQ-9174
Description
The National Instruments cDAQ-9174 is a four-slot USB CompactDAQ chassis for building modular measurement and control systems. It connects compatible C Series modules to a computer and provides hardware timing, data streaming, and counter resources for coordinated acquisition and signal generation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | National Instruments |
| Category | Data Acquisition |
| Part Number | cDAQ-9174 |
| Subcategory | CompactDAQ Chassis |
| Module Slots | 4 |
| Host Interface | USB 2.0 Hi-Speed |
| Module Compatibility | Supported National Instruments C Series modules |
| Input Power Requirement | 9–30 VDC; 15 W maximum; NEC Class 2 power source |
| Power Connector | Two-position, 3.5 mm pitch pluggable screw terminal with screw locks |
| Timing Resolution | 12.5 ns |
| Timing Accuracy | 50 ppm |
| Analog Input FIFO | 127 samples per slot |
| Analog Input Rate and Channels | Determined by installed C Series modules |
| Analog Output Regeneration | Up to 16 channels; 1.6 MS/s maximum aggregate rate, subject to module capability |
| Analog Output FIFO | 8,191 samples shared during onboard regeneration; 127 samples per slot without regeneration |
| Counters and Timers | Four, 32-bit; internal base clocks of 80 MHz, 20 MHz, and 100 kHz |
| High-Performance Data Streams | 7 |
| Enclosure and Operating Temperature | IP30; −20 to +55 °C; indoor use |
| Dimensions | 159.5 × 88.1 × 58.9 mm (6.28 × 3.47 × 2.3 in), unloaded |
| Weight | 574 g (20.2 oz; 1.27 lb) |
Information About cDAQ-9174
The cDAQ-9174 is designed to combine different C Series measurement functions within one externally powered chassis. Its USB 2.0 Hi-Speed interface supports seven high-performance data streams for compatible input, output, and counter tasks. Four onboard 32-bit counters provide resources for pulse measurement, event counting, and position tracking through suitable module connections. The installed modules determine signal compatibility, channel counts, and achievable acquisition rates.
Key Features:
- Four Module Slots: Accommodates up to four compatible National Instruments C Series modules.
- USB Host Connection: Uses USB 2.0 Hi-Speed communication for computer-based operation.
- Hardware Timing: Provides 12.5 ns timing resolution for supported acquisition and generation functions.
- Four Counters: Includes four 32-bit general-purpose counters and timers.
- Multiple Data Streams: Supports seven high-performance streams for compatible measurement tasks.
- Analog Output Regeneration: Supports waveform generation from onboard memory with suitable output modules.
- Module-Based Triggering: Routes supported digital triggers through module PFI terminals.
- External DC Power: Operates from a 9–30 VDC supply with a maximum required input power of 15 W.
The cDAQ-9174 delivers the reliability and precision required for modular data acquisition and coordinated test system operation.
Description
The National Instruments cDAQ-9174 is a four-slot USB CompactDAQ chassis for building modular measurement and control systems. It connects compatible C Series modules to a computer and provides hardware timing, data streaming, and counter resources for coordinated acquisition and signal generation.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | National Instruments |
| Category | Data Acquisition |
| Part Number | cDAQ-9174 |
| Subcategory | CompactDAQ Chassis |
| Module Slots | 4 |
| Host Interface | USB 2.0 Hi-Speed |
| Module Compatibility | Supported National Instruments C Series modules |
| Input Power Requirement | 9–30 VDC; 15 W maximum; NEC Class 2 power source |
| Power Connector | Two-position, 3.5 mm pitch pluggable screw terminal with screw locks |
| Timing Resolution | 12.5 ns |
| Timing Accuracy | 50 ppm |
| Analog Input FIFO | 127 samples per slot |
| Analog Input Rate and Channels | Determined by installed C Series modules |
| Analog Output Regeneration | Up to 16 channels; 1.6 MS/s maximum aggregate rate, subject to module capability |
| Analog Output FIFO | 8,191 samples shared during onboard regeneration; 127 samples per slot without regeneration |
| Counters and Timers | Four, 32-bit; internal base clocks of 80 MHz, 20 MHz, and 100 kHz |
| High-Performance Data Streams | 7 |
| Enclosure and Operating Temperature | IP30; −20 to +55 °C; indoor use |
| Dimensions | 159.5 × 88.1 × 58.9 mm (6.28 × 3.47 × 2.3 in), unloaded |
| Weight | 574 g (20.2 oz; 1.27 lb) |
Information About cDAQ-9174
The cDAQ-9174 is designed to combine different C Series measurement functions within one externally powered chassis. Its USB 2.0 Hi-Speed interface supports seven high-performance data streams for compatible input, output, and counter tasks. Four onboard 32-bit counters provide resources for pulse measurement, event counting, and position tracking through suitable module connections. The installed modules determine signal compatibility, channel counts, and achievable acquisition rates.
Key Features:
- Four Module Slots: Accommodates up to four compatible National Instruments C Series modules.
- USB Host Connection: Uses USB 2.0 Hi-Speed communication for computer-based operation.
- Hardware Timing: Provides 12.5 ns timing resolution for supported acquisition and generation functions.
- Four Counters: Includes four 32-bit general-purpose counters and timers.
- Multiple Data Streams: Supports seven high-performance streams for compatible measurement tasks.
- Analog Output Regeneration: Supports waveform generation from onboard memory with suitable output modules.
- Module-Based Triggering: Routes supported digital triggers through module PFI terminals.
- External DC Power: Operates from a 9–30 VDC supply with a maximum required input power of 15 W.
The cDAQ-9174 delivers the reliability and precision required for modular data acquisition and coordinated test system operation.