National Instruments PXI-5112 Two-Channel PXI Digitizer with Deep Memory and Simultaneous Waveform Acquisition
- Regular price
- $5,199.00
- Sale price
- $5,199.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: PXI-5112
Description
The National Instruments PXI-5112 is a two-channel digitizer for capturing and analyzing electrical waveforms in compatible PXI test systems. It combines 100 MHz analog bandwidth with 8-bit resolution and simultaneous real-time sampling at up to 100 MS/s per channel.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | National Instruments |
| Category | Test and Measurement |
| Part Number | PXI-5112 |
| Subcategory | PXI Digitizers and Oscilloscopes |
| Product Type | Two-channel high-speed digitizer |
| Analog Input Channels | 2, single-ended |
| Sampling Mode | Simultaneous |
| ADC Resolution | 8 bit |
| Maximum Analog Bandwidth | 100 MHz |
| Bandwidth Limit Setting | 20 MHz typical when enabled |
| Real-Time Sample Rate | 1 S/s to 100 MS/s |
| Maximum RIS Sample Rate | 2.5 GS/s effective, repetitive signals only |
| Onboard Sample Memory | 16 or 32 MB per channel; configuration dependent |
| Calibrated Vertical Ranges | ±25 mV to ±25 V in 10% steps |
| Input Coupling | AC or DC, software-selectable |
| Input Impedance | 1 MΩ in parallel with 30 pF, or 50 Ω |
| Analog Input Connectors | Two BNC female connectors |
| Operating Temperature | 0 to +40 °C |
| Module Dimensions | 100 × 160 mm (3.9 × 6.3 in) |
| Weight | 1 lb |
Information About PXI-5112
The PXI-5112 provides onboard acquisition memory of 16 or 32 MB per channel, depending on the installed option. Its software-selectable input coupling and impedance support different signal measurement requirements. Random-interleaved sampling provides effective rates up to 2.5 GS/s for repetitive signals. Multiple-record acquisition and configurable triggering support the capture of separate waveform events without transferring each record immediately to the host.
Key Features:
- Dual-Channel Acquisition: Samples two single-ended analog inputs simultaneously.
- Wide Analog Bandwidth: Supports signal bandwidths up to 100 MHz.
- Real-Time Sampling: Acquires transient or repetitive signals at up to 100 MS/s.
- Repetitive Signal Sampling: Provides effective rates up to 2.5 GS/s using random-interleaved sampling.
- Deep Acquisition Memory: Offers 16 or 32 MB per channel, depending on configuration.
- Adjustable Vertical Range: Supports calibrated ranges from ±25 mV to ±25 V.
- Multiple-Record Capture: Stores successive triggered waveform records in onboard memory.
- Flexible Input Settings: Provides software-selectable AC/DC coupling and 50 Ω or 1 MΩ input impedance.
The PXI-5112 delivers the reliability and precision required for waveform acquisition and signal analysis in automated test systems.
Description
The National Instruments PXI-5112 is a two-channel digitizer for capturing and analyzing electrical waveforms in compatible PXI test systems. It combines 100 MHz analog bandwidth with 8-bit resolution and simultaneous real-time sampling at up to 100 MS/s per channel.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | National Instruments |
| Category | Test and Measurement |
| Part Number | PXI-5112 |
| Subcategory | PXI Digitizers and Oscilloscopes |
| Product Type | Two-channel high-speed digitizer |
| Analog Input Channels | 2, single-ended |
| Sampling Mode | Simultaneous |
| ADC Resolution | 8 bit |
| Maximum Analog Bandwidth | 100 MHz |
| Bandwidth Limit Setting | 20 MHz typical when enabled |
| Real-Time Sample Rate | 1 S/s to 100 MS/s |
| Maximum RIS Sample Rate | 2.5 GS/s effective, repetitive signals only |
| Onboard Sample Memory | 16 or 32 MB per channel; configuration dependent |
| Calibrated Vertical Ranges | ±25 mV to ±25 V in 10% steps |
| Input Coupling | AC or DC, software-selectable |
| Input Impedance | 1 MΩ in parallel with 30 pF, or 50 Ω |
| Analog Input Connectors | Two BNC female connectors |
| Operating Temperature | 0 to +40 °C |
| Module Dimensions | 100 × 160 mm (3.9 × 6.3 in) |
| Weight | 1 lb |
Information About PXI-5112
The PXI-5112 provides onboard acquisition memory of 16 or 32 MB per channel, depending on the installed option. Its software-selectable input coupling and impedance support different signal measurement requirements. Random-interleaved sampling provides effective rates up to 2.5 GS/s for repetitive signals. Multiple-record acquisition and configurable triggering support the capture of separate waveform events without transferring each record immediately to the host.
Key Features:
- Dual-Channel Acquisition: Samples two single-ended analog inputs simultaneously.
- Wide Analog Bandwidth: Supports signal bandwidths up to 100 MHz.
- Real-Time Sampling: Acquires transient or repetitive signals at up to 100 MS/s.
- Repetitive Signal Sampling: Provides effective rates up to 2.5 GS/s using random-interleaved sampling.
- Deep Acquisition Memory: Offers 16 or 32 MB per channel, depending on configuration.
- Adjustable Vertical Range: Supports calibrated ranges from ±25 mV to ±25 V.
- Multiple-Record Capture: Stores successive triggered waveform records in onboard memory.
- Flexible Input Settings: Provides software-selectable AC/DC coupling and 50 Ω or 1 MΩ input impedance.
The PXI-5112 delivers the reliability and precision required for waveform acquisition and signal analysis in automated test systems.