Notifier NCM-W NOTI-FIRE-NET Network Communications Module
- Regular price
- $797.00
- Sale price
- $797.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: NCM-W
Description
The Notifier NCM-W is a Network Communications Module designed to connect NOTIFIER intelligent fire alarm control panels and network annunciators through the NOTI•FIRE•NET™ communication network. It provides reliable data exchange over shielded twisted-pair wiring, allowing multiple fire alarm nodes, control panels, and network devices to operate as an integrated system. The module is used for distributed fire alarm monitoring, programming access, and network expansion in commercial life safety applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Notifier |
| Category | Fire Alarm Systems |
| Part Number | NCM-W |
| Subcategory | Network Communications Module |
| Product Type | NOTI•FIRE•NET™ Network Communications Module |
| Compatible Systems | NFS-640, NFS-3030, NFS2-3030, NCA, NCA-2 |
| Network Medium | Shielded twisted-pair copper |
| Communication Protocol | NOTI•FIRE•NET™ |
| Transmission Rate | 312.5 Kbaud |
| Wiring Style | NFPA Style 4 (Class B), NFPA Style 7 (Class A) |
| Maximum Distance Between Nodes | Up to 3,000 ft (914 m) |
| Network Ports | 2 communication ports |
| Network Topology | Open or closed loop operation |
| Isolation Method | Transformer-coupled inputs |
| Configuration Features | DIP-switch enabled ground fault detection and EOL resistors |
| Compatible Devices | MIB-W, MIB-WF, NAM-232W, NCM-W, NCS-W, RPT-W, RPT-WF |
| Terminal Connection | Pluggable terminal blocks with strain relief |
| Application | Commercial fire alarm network communication |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Weight | Approximately 0.75 lbs |
Information About NCM-W
The NCM-W is part of the NOTIFIER Network Communications Module family, providing a wired interface between NFS-640, NFS-3030, NFS2-3030 fire alarm control panels and NCA/NCA-2 network annunciators. The module uses transformer-coupled network connections, dual communication ports, and configurable switches for ground fault detection and end-of-line termination. It supports NOTI•FIRE•NET™ network architectures using shielded twisted-pair copper wiring with Class A or Class B configurations. The NCM-W is designed for integration with devices such as MIB-W, NAM-232W, RPT-W, NCS-W, and additional NCM modules in large-scale fire protection systems.
Key Features:
- NOTI•FIRE•NET™ Network Interface: Provides communication between intelligent NOTIFIER fire alarm panels and network control devices.
- Twisted-Pair Communication: Uses shielded copper wiring for reliable network data transmission between system nodes.
- Dual Network Ports: Includes two ports for flexible trunk connections and side-load programming configurations.
- Class A and Class B Support: Compatible with NFPA Style 7 (Class A) and NFPA Style 4 (Class B) network wiring.
- Extended Node Distance: Supports up to 3,000 ft (914 m) between adjacent network nodes.
- Transformer-Coupled Isolation: Provides electrical isolation between connected network nodes to improve system stability.
- Ground Fault Detection: Includes DIP-switch enabled ground fault monitoring for network troubleshooting.
- Built-In End-of-Line Resistors: Allows activation of onboard termination resistors through configuration switches.
- Flexible Network Topology: Supports open and closed loop network arrangements for different installation requirements.
- Broad System Compatibility: Works with NFS-640, NFS-3030, NFS2-3030, NCA, NCA-2, and compatible NOTIFIER network modules.
- Simplified Installation: Features pluggable terminal blocks with strain relief for secure field wiring.
- High Reliability Communication: Provides stable network connectivity for distributed fire alarm system operation.
The NCM-W delivers the reliability and precision required for NOTIFIER fire alarm network communication and multi-panel life safety system integration.
Description
The Notifier NCM-W is a Network Communications Module designed to connect NOTIFIER intelligent fire alarm control panels and network annunciators through the NOTI•FIRE•NET™ communication network. It provides reliable data exchange over shielded twisted-pair wiring, allowing multiple fire alarm nodes, control panels, and network devices to operate as an integrated system. The module is used for distributed fire alarm monitoring, programming access, and network expansion in commercial life safety applications.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Notifier |
| Category | Fire Alarm Systems |
| Part Number | NCM-W |
| Subcategory | Network Communications Module |
| Product Type | NOTI•FIRE•NET™ Network Communications Module |
| Compatible Systems | NFS-640, NFS-3030, NFS2-3030, NCA, NCA-2 |
| Network Medium | Shielded twisted-pair copper |
| Communication Protocol | NOTI•FIRE•NET™ |
| Transmission Rate | 312.5 Kbaud |
| Wiring Style | NFPA Style 4 (Class B), NFPA Style 7 (Class A) |
| Maximum Distance Between Nodes | Up to 3,000 ft (914 m) |
| Network Ports | 2 communication ports |
| Network Topology | Open or closed loop operation |
| Isolation Method | Transformer-coupled inputs |
| Configuration Features | DIP-switch enabled ground fault detection and EOL resistors |
| Compatible Devices | MIB-W, MIB-WF, NAM-232W, NCM-W, NCS-W, RPT-W, RPT-WF |
| Terminal Connection | Pluggable terminal blocks with strain relief |
| Application | Commercial fire alarm network communication |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Weight | Approximately 0.75 lbs |
Information About NCM-W
The NCM-W is part of the NOTIFIER Network Communications Module family, providing a wired interface between NFS-640, NFS-3030, NFS2-3030 fire alarm control panels and NCA/NCA-2 network annunciators. The module uses transformer-coupled network connections, dual communication ports, and configurable switches for ground fault detection and end-of-line termination. It supports NOTI•FIRE•NET™ network architectures using shielded twisted-pair copper wiring with Class A or Class B configurations. The NCM-W is designed for integration with devices such as MIB-W, NAM-232W, RPT-W, NCS-W, and additional NCM modules in large-scale fire protection systems.
Key Features:
- NOTI•FIRE•NET™ Network Interface: Provides communication between intelligent NOTIFIER fire alarm panels and network control devices.
- Twisted-Pair Communication: Uses shielded copper wiring for reliable network data transmission between system nodes.
- Dual Network Ports: Includes two ports for flexible trunk connections and side-load programming configurations.
- Class A and Class B Support: Compatible with NFPA Style 7 (Class A) and NFPA Style 4 (Class B) network wiring.
- Extended Node Distance: Supports up to 3,000 ft (914 m) between adjacent network nodes.
- Transformer-Coupled Isolation: Provides electrical isolation between connected network nodes to improve system stability.
- Ground Fault Detection: Includes DIP-switch enabled ground fault monitoring for network troubleshooting.
- Built-In End-of-Line Resistors: Allows activation of onboard termination resistors through configuration switches.
- Flexible Network Topology: Supports open and closed loop network arrangements for different installation requirements.
- Broad System Compatibility: Works with NFS-640, NFS-3030, NFS2-3030, NCA, NCA-2, and compatible NOTIFIER network modules.
- Simplified Installation: Features pluggable terminal blocks with strain relief for secure field wiring.
- High Reliability Communication: Provides stable network connectivity for distributed fire alarm system operation.
The NCM-W delivers the reliability and precision required for NOTIFIER fire alarm network communication and multi-panel life safety system integration.