Product Description P/N: PFC-6006
Description
Potter Electric Signal PFC-6006 is a conventional fire alarm control panel designed for small fire systems, including sprinkler monitoring. It provides six programmable initiating circuits, a notification appliance circuit, and onboard communication and Ethernet functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Potter Electric Signal |
| Category | Fire Alarm Control Panels |
| Part Number | PFC-6006 |
| Subcategory | Conventional Fire Panels |
| Initiating Device Circuits | 6 programmable circuits |
| Waterflow Circuit | Selectable Class A or Class B |
| Smoke Detector Compatibility | Two-wire smoke detectors on selectable circuits |
| Notification Circuit | 1 regulated circuit, 0.5 A |
| Power Supply | 1.0 A |
| AC Input | 120 VAC, 60 Hz |
| Auxiliary Power | 0.5 A, programmable constant or resettable |
| Display | 2 × 16 character LCD |
| Communication | Onboard dual-line DACT and Ethernet with listed IP communicator |
| Battery Capacity | Supports up to 18 Ah batteries |
| Enclosure Dimensions | 18½ × 14¼ × 4¾ in |
| Weight | 20 lb |
Information About PFC-6006
The PFC-6006 is part of Potter’s conventional fire panel range. Its first initiating circuit can be configured as a Class A or Class B waterflow input, while the other five circuits support selectable functions such as two-wire smoke detection. The panel includes a 1.0 A power supply, an onboard dual-line digital alarm communicator, and an Ethernet connection with an IP communicator. A 2 × 16 LCD, system LEDs, and keypad provide local status viewing and control.
Key Features:
- Six Programmable Circuits: Provides six initiating device circuits for fire system inputs and monitoring.
- Selectable Waterflow Circuit: Configures the first circuit for Class A or Class B waterflow monitoring.
- Two-Wire Smoke Support: Allows compatible two-wire smoke detection on selectable zones.
- Notification Appliance Circuit: Includes one regulated notification circuit rated at 0.5 A.
- Integrated Power Supply: Provides a 1.0 A supply for the panel, battery charging, and auxiliary power.
- Dual-Line Communicator: Includes an onboard digital alarm communicator for remote station communication.
- Local Status Interface: Uses a 2 × 16 LCD, status LEDs, and keypad for system information and controls
The PFC-6006 delivers the reliability and precision required for conventional fire alarm and sprinkler monitoring systems.
Description
Potter Electric Signal PFC-6006 is a conventional fire alarm control panel designed for small fire systems, including sprinkler monitoring. It provides six programmable initiating circuits, a notification appliance circuit, and onboard communication and Ethernet functions.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Potter Electric Signal |
| Category | Fire Alarm Control Panels |
| Part Number | PFC-6006 |
| Subcategory | Conventional Fire Panels |
| Initiating Device Circuits | 6 programmable circuits |
| Waterflow Circuit | Selectable Class A or Class B |
| Smoke Detector Compatibility | Two-wire smoke detectors on selectable circuits |
| Notification Circuit | 1 regulated circuit, 0.5 A |
| Power Supply | 1.0 A |
| AC Input | 120 VAC, 60 Hz |
| Auxiliary Power | 0.5 A, programmable constant or resettable |
| Display | 2 × 16 character LCD |
| Communication | Onboard dual-line DACT and Ethernet with listed IP communicator |
| Battery Capacity | Supports up to 18 Ah batteries |
| Enclosure Dimensions | 18½ × 14¼ × 4¾ in |
| Weight | 20 lb |
Information About PFC-6006
The PFC-6006 is part of Potter’s conventional fire panel range. Its first initiating circuit can be configured as a Class A or Class B waterflow input, while the other five circuits support selectable functions such as two-wire smoke detection. The panel includes a 1.0 A power supply, an onboard dual-line digital alarm communicator, and an Ethernet connection with an IP communicator. A 2 × 16 LCD, system LEDs, and keypad provide local status viewing and control.
Key Features:
- Six Programmable Circuits: Provides six initiating device circuits for fire system inputs and monitoring.
- Selectable Waterflow Circuit: Configures the first circuit for Class A or Class B waterflow monitoring.
- Two-Wire Smoke Support: Allows compatible two-wire smoke detection on selectable zones.
- Notification Appliance Circuit: Includes one regulated notification circuit rated at 0.5 A.
- Integrated Power Supply: Provides a 1.0 A supply for the panel, battery charging, and auxiliary power.
- Dual-Line Communicator: Includes an onboard digital alarm communicator for remote station communication.
- Local Status Interface: Uses a 2 × 16 LCD, status LEDs, and keypad for system information and controls
The PFC-6006 delivers the reliability and precision required for conventional fire alarm and sprinkler monitoring systems.