Product Description P/N: QF215A
Description
The Siemens QF215A is a two-pole GFCI circuit breaker designed to provide ground-fault protection for 240V branch circuits. Rated at 15 A with a 10 kA interrupting capacity, this breaker incorporates a self-test function and thermal magnetic trip technology to support reliable protection in compatible Siemens load centers.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Circuit Breaker |
| Part Number | QF215A |
| Subcategory | Molded Case Circuit Breaker |
| Breaker Series | Q / QP |
| Frame Type | QPF2 |
| Breaker Type | GFCI Circuit Breaker |
| Amperage Rating | 15 A |
| Voltage Rating | 240 VAC |
| Number of Poles | 2 |
| Phase | Single-Phase |
| Frequency Rating | 50/60 Hz |
| Trip Type | Thermal Magnetic |
| Ground Fault Trip Range | 0–5 mA |
| Interrupt Rating | 10 kA |
| Connection Type | Plug-In |
| Wire Size | AWG 14–10, AWG 12–8 |
| Temperature Rating | 40 °C |
| Certifications | UL Listed, CSA Licensed |
| HACR Rated | Yes |
| Dimensions | 7 in L × 5 in W × 5 in H |
Information About QF215A
The QF215A is a GFCI circuit breaker from the Siemens Q / QP family, engineered for enhanced personnel protection in 240V electrical circuits. It is designed for use in Siemens Type EQ, EQL, SEQ, EQG, PL, and ES series load centers, ensuring mechanical and electrical compatibility. The breaker features an integrated self-test function that continuously monitors GFCI operation to maintain protection integrity. Its thermal magnetic trip unit provides coordinated response to overloads, short circuits, and ground-fault conditions.
Key Features
- Siemens QPF2 GFCI Design: Developed for use in Siemens Q / QP series load centers and panelboards.
- 15A, 2-Pole Configuration: Suitable for 240V branch circuits requiring ground-fault protection.
- Integrated Self-Test Function: Continuously verifies GFCI functionality to ensure ongoing protection.
- 5 mA Ground Fault Sensitivity: Quickly interrupts power to reduce the risk of electrical shock.
- Thermal Magnetic Trip Unit: Provides combined overload and short-circuit protection.
- 10 kA Interrupting Capacity: Supports reliable fault current interruption.
- HACR Rated and Certified: UL Listed and CSA licensed for HVAC and refrigeration-related applications.
The QF215A delivers the reliability and precision required for ground-fault protection of 240V circuits in residential and commercial electrical systems.
Description
The Siemens QF215A is a two-pole GFCI circuit breaker designed to provide ground-fault protection for 240V branch circuits. Rated at 15 A with a 10 kA interrupting capacity, this breaker incorporates a self-test function and thermal magnetic trip technology to support reliable protection in compatible Siemens load centers.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Circuit Breaker |
| Part Number | QF215A |
| Subcategory | Molded Case Circuit Breaker |
| Breaker Series | Q / QP |
| Frame Type | QPF2 |
| Breaker Type | GFCI Circuit Breaker |
| Amperage Rating | 15 A |
| Voltage Rating | 240 VAC |
| Number of Poles | 2 |
| Phase | Single-Phase |
| Frequency Rating | 50/60 Hz |
| Trip Type | Thermal Magnetic |
| Ground Fault Trip Range | 0–5 mA |
| Interrupt Rating | 10 kA |
| Connection Type | Plug-In |
| Wire Size | AWG 14–10, AWG 12–8 |
| Temperature Rating | 40 °C |
| Certifications | UL Listed, CSA Licensed |
| HACR Rated | Yes |
| Dimensions | 7 in L × 5 in W × 5 in H |
Information About QF215A
The QF215A is a GFCI circuit breaker from the Siemens Q / QP family, engineered for enhanced personnel protection in 240V electrical circuits. It is designed for use in Siemens Type EQ, EQL, SEQ, EQG, PL, and ES series load centers, ensuring mechanical and electrical compatibility. The breaker features an integrated self-test function that continuously monitors GFCI operation to maintain protection integrity. Its thermal magnetic trip unit provides coordinated response to overloads, short circuits, and ground-fault conditions.
Key Features
- Siemens QPF2 GFCI Design: Developed for use in Siemens Q / QP series load centers and panelboards.
- 15A, 2-Pole Configuration: Suitable for 240V branch circuits requiring ground-fault protection.
- Integrated Self-Test Function: Continuously verifies GFCI functionality to ensure ongoing protection.
- 5 mA Ground Fault Sensitivity: Quickly interrupts power to reduce the risk of electrical shock.
- Thermal Magnetic Trip Unit: Provides combined overload and short-circuit protection.
- 10 kA Interrupting Capacity: Supports reliable fault current interruption.
- HACR Rated and Certified: UL Listed and CSA licensed for HVAC and refrigeration-related applications.
The QF215A delivers the reliability and precision required for ground-fault protection of 240V circuits in residential and commercial electrical systems.