R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
    R7795C1007 | Honeywell Electronic Programming Primary Burner Control
    R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control
R7795C1007 | Honeywell Electronic Programming Primary Burner Control

R7795C1007 | Honeywell Electronic Programming Primary Burner Control

Part #: R7795C1007 Manufactured by: Honeywell
Regular price
$4,884.00
Sale price
$4,884.00
Regular price
1 in Stock
Condition: New-Surplus Original Box
Shipping calculated at checkout.
Product Overview
The R7795C1007 is an electronic primary burner control that manages ignition safety, airflow proving, and flame supervisio...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Contact Us!

Talk to a real expert.

Mon–Sat, 7:00 AM – 8:00 PM (EST)
warranty
IQElectro 2-Year Warranty
Warranty for Product #: R7795C1007
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro BBB Business Review
IQElectro is Not an authorized distributor for Honeywell
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: R7795C1007

Description / Specifications

Description 

The Honeywell R7795C1007 is a solid-state primary safety control designed for intermittent pilot burner systems with ultraviolet flame detection. It provides fast flame failure response and reliable electronic flame safeguard protection for commercial and industrial single- or dual-fuel burners.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category Burner Controls
Part Number R7795C1007
Subcategory Primary Burner Controls
Control Type Electronic programming relay
Pilot Type Interrupted pilot
Flame Detection Ultraviolet (UV)
Supply Voltage 120 VAC
Supply Frequency 50/60 Hz
Flame Failure Response Time 3 seconds
Safety Switch Timing 10–15 seconds
Prepurge Timer Plug-in, selectable (1.5 / 7 / 10 / 30 / 60 / 90 s)
Airflow Switch Input Line voltage
Mounting Q795A wiring subbase
Operating Temperature -40 to +135 °F
Weight 2.1 lbs

 


Information About R7795C1007

The R7795C1007 is part of Honeywell’s electronic primary control lineup developed for robust flame safeguard protection in industrial combustion systems. It uses ultraviolet flame sensing with a purple-coded amplifier and requires a compatible plug-in prepurge timer to define purge duration. The control mounts on a Q795A wiring subbase and continuously monitors airflow from the start of prepurge through the run period. Built-in lockout logic prevents unsafe startup conditions if flame presence or flame-simulating faults are detected.

Key Features

  • Primary Flame Safeguard Control: Provides solid-state electronic protection for commercial and industrial burner applications.
  • Interrupted Pilot Operation: Supports controlled ignition sequences for interrupted pilot burner systems.
  • Ultraviolet Flame Detection: Uses UV sensing for reliable flame supervision in demanding combustion environments.
  • Fast Flame Failure Response: 3-second response time minimizes unsafe fuel conditions during flame loss.
  • Selectable Prepurge Timing: Requires plug-in timers offering multiple purge durations for application flexibility.
  • Airflow Proving Capability: Monitors a line-voltage airflow switch throughout prepurge and burner operation.
  • Wide Temperature Rating: Designed for operation from -40 to +135 °F in harsh industrial settings.

The R7795C1007 delivers the reliability and precision required for safe interrupted pilot burner control in industrial combustion systems.

Get fast quote and compatibility check
Compatibility check available   ·   Alternative parts suggested
Get a response to your request within 5 minutes
Talk to a real industrial automation specialist.
We verify compatibility, suggest alternatives, and provide fast quotes.
Something went wrong, please try again
Form image
Arty A.
Senior Sales Manager
Daniel S.
Parts Specialist
Request successfully sent!
Estimated response time: 1 to 5 minutes.
Description / Specifications

Description 

The Honeywell R7795C1007 is a solid-state primary safety control designed for intermittent pilot burner systems with ultraviolet flame detection. It provides fast flame failure response and reliable electronic flame safeguard protection for commercial and industrial single- or dual-fuel burners.

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category Burner Controls
Part Number R7795C1007
Subcategory Primary Burner Controls
Control Type Electronic programming relay
Pilot Type Interrupted pilot
Flame Detection Ultraviolet (UV)
Supply Voltage 120 VAC
Supply Frequency 50/60 Hz
Flame Failure Response Time 3 seconds
Safety Switch Timing 10–15 seconds
Prepurge Timer Plug-in, selectable (1.5 / 7 / 10 / 30 / 60 / 90 s)
Airflow Switch Input Line voltage
Mounting Q795A wiring subbase
Operating Temperature -40 to +135 °F
Weight 2.1 lbs

 


Information About R7795C1007

The R7795C1007 is part of Honeywell’s electronic primary control lineup developed for robust flame safeguard protection in industrial combustion systems. It uses ultraviolet flame sensing with a purple-coded amplifier and requires a compatible plug-in prepurge timer to define purge duration. The control mounts on a Q795A wiring subbase and continuously monitors airflow from the start of prepurge through the run period. Built-in lockout logic prevents unsafe startup conditions if flame presence or flame-simulating faults are detected.

Key Features

  • Primary Flame Safeguard Control: Provides solid-state electronic protection for commercial and industrial burner applications.
  • Interrupted Pilot Operation: Supports controlled ignition sequences for interrupted pilot burner systems.
  • Ultraviolet Flame Detection: Uses UV sensing for reliable flame supervision in demanding combustion environments.
  • Fast Flame Failure Response: 3-second response time minimizes unsafe fuel conditions during flame loss.
  • Selectable Prepurge Timing: Requires plug-in timers offering multiple purge durations for application flexibility.
  • Airflow Proving Capability: Monitors a line-voltage airflow switch throughout prepurge and burner operation.
  • Wide Temperature Rating: Designed for operation from -40 to +135 °F in harsh industrial settings.

The R7795C1007 delivers the reliability and precision required for safe interrupted pilot burner control in industrial combustion systems.