Product Overview
The Honeywell RM7838B1013 Burner Control 120V, 50/60 HZ. SELECTABLE INTERMITTENT OR INTERRUPTED Pilot. Pilot Valve HOLD, M...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: RM7838B1013
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Honeywell
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.
RM7838B1013 | Honeywell Burner Control
    RM7838B1013 | Honeywell Burner Control
RM7838B1013 | Honeywell Burner Control

Product Description P/N: RM7838B1013

Description / Specifications

Description 


Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.

 

Technical Specifications 

 

Brand Honeywell
Category Flame Safety Products
Sub-Category Flame Safety Amplifier
Part Number RM7838B1013
Application Semi Automatic Programming Control
Dimensions (in.) 5 in. wide x 5 in. high x 5 1/4 in. deep with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
Dimensions (mm) 127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase x 155 mm deep with Q7800B Subbase
Frequency 50 Hz; 60 Hz (±10%)
Voltage 120 Vac (+10, -15%)
Shipping and Storage Temperature Range (F) -40 F to +140 F
Shipping and Storage Temperature Range (C) -40 C to +60 C
Flame Establishing Period – Pilot 4 sec or 10 sec
Flame Establishing Period – Main 10 sec or Intermittent
Interlocks Lockout
Preignition Yes
PrePurge Determined by ST7800A Purge Timer Card
Early Spark Termination Yes, 5 sec
Required Components Q7800A,B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Pilot Type interrupted
Vibration 5 G environment

  

 

Information About RM7838B1013

Features

Functions include purge, burner pilot startup, flame supervision, system status indication, system or self diagnosis and troubleshooting.
Delays admission of fuel to combustion chamber until pilot flame has been proven and then monitors the flame through the run period while providing system status indication.
Includes Keyboard Display Module.
Five LEDs provide sequence information.
Intermittent pilot valve.
Interchangeable plug-in flame amplifier.
Access for external electrical voltage checks.
Nonvolatile memory retains history files and lockout status after loss of power.
Selectable pilot flame establishing period.
Provides application flexibility and optional communication interface capability.
Compatible with existing Honeywell flame detectors.



Manufacturer information

Honeywell, a global technology leader, specializes in diverse industries, including aerospace, automation, and safety solutions. With a legacy spanning over a century, Honeywell continues to innovate and provide cutting-edge technologies for a safer, more sustainable world. Their commitment to quality and excellence has made them a trusted brand worldwide.

IQElectro is not an authorized distributor.
QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 


Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.

 

Technical Specifications 

 

Brand Honeywell
Category Flame Safety Products
Sub-Category Flame Safety Amplifier
Part Number RM7838B1013
Application Semi Automatic Programming Control
Dimensions (in.) 5 in. wide x 5 in. high x 5 1/4 in. deep with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase
Dimensions (mm) 127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase x 155 mm deep with Q7800B Subbase
Frequency 50 Hz; 60 Hz (±10%)
Voltage 120 Vac (+10, -15%)
Shipping and Storage Temperature Range (F) -40 F to +140 F
Shipping and Storage Temperature Range (C) -40 C to +60 C
Flame Establishing Period – Pilot 4 sec or 10 sec
Flame Establishing Period – Main 10 sec or Intermittent
Interlocks Lockout
Preignition Yes
PrePurge Determined by ST7800A Purge Timer Card
Early Spark Termination Yes, 5 sec
Required Components Q7800A,B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card.
Pilot Type interrupted
Vibration 5 G environment

  

 

Information About RM7838B1013

Features

Functions include purge, burner pilot startup, flame supervision, system status indication, system or self diagnosis and troubleshooting.
Delays admission of fuel to combustion chamber until pilot flame has been proven and then monitors the flame through the run period while providing system status indication.
Includes Keyboard Display Module.
Five LEDs provide sequence information.
Intermittent pilot valve.
Interchangeable plug-in flame amplifier.
Access for external electrical voltage checks.
Nonvolatile memory retains history files and lockout status after loss of power.
Selectable pilot flame establishing period.
Provides application flexibility and optional communication interface capability.
Compatible with existing Honeywell flame detectors.



Manufacturer information

Honeywell, a global technology leader, specializes in diverse industries, including aerospace, automation, and safety solutions. With a legacy spanning over a century, Honeywell continues to innovate and provide cutting-edge technologies for a safer, more sustainable world. Their commitment to quality and excellence has made them a trusted brand worldwide.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)