Product Description P/N: RM7838B1013
Description
Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.
Technical Specifications
Brand | Honeywell |
Category | Flame Safety Products |
Sub-Category | Flame Safety Amplifier |
Part Number | RM7838B1013 |
Application | Semi Automatic Programming Control |
Dimensions (in.) | 5 in. wide x 5 in. high x 5 1/4 in. deep with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase |
Dimensions (mm) | 127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase x 155 mm deep with Q7800B Subbase |
Frequency | 50 Hz; 60 Hz (±10%) |
Voltage | 120 Vac (+10, -15%) |
Shipping and Storage Temperature Range (F) | -40 F to +140 F |
Shipping and Storage Temperature Range (C) | -40 C to +60 C |
Flame Establishing Period – Pilot | 4 sec or 10 sec |
Flame Establishing Period – Main | 10 sec or Intermittent |
Interlocks | Lockout |
Preignition | Yes |
PrePurge | Determined by ST7800A Purge Timer Card |
Early Spark Termination | Yes, 5 sec |
Required Components | Q7800A,B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card. |
Pilot Type | interrupted |
Vibration | 5 G environment |
Information About RM7838B1013
Features
Functions include purge, burner pilot startup, flame supervision, system status indication, system or self diagnosis and troubleshooting.
Delays admission of fuel to combustion chamber until pilot flame has been proven and then monitors the flame through the run period while providing system status indication.
Includes Keyboard Display Module.
Five LEDs provide sequence information.
Intermittent pilot valve.
Interchangeable plug-in flame amplifier.
Access for external electrical voltage checks.
Nonvolatile memory retains history files and lockout status after loss of power.
Selectable pilot flame establishing period.
Provides application flexibility and optional communication interface capability.
Compatible with existing Honeywell flame detectors.
Manufacturer information
Honeywell, a global technology leader, specializes in diverse industries, including aerospace, automation, and safety solutions. With a legacy spanning over a century, Honeywell continues to innovate and provide cutting-edge technologies for a safer, more sustainable world. Their commitment to quality and excellence has made them a trusted brand worldwide.
Description
Microprocessor-based integrated burner control for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications. Provides level of safety, functional capability and features beyond conventional controls.
Technical Specifications
Brand | Honeywell |
Category | Flame Safety Products |
Sub-Category | Flame Safety Amplifier |
Part Number | RM7838B1013 |
Application | Semi Automatic Programming Control |
Dimensions (in.) | 5 in. wide x 5 in. high x 5 1/4 in. deep with Q7800A Subbase x 6 3/32 in. deep with Q7800B Subbase |
Dimensions (mm) | 127 mm wide x 127 mm high x 133 mm deep with Q7800A Subbase x 155 mm deep with Q7800B Subbase |
Frequency | 50 Hz; 60 Hz (±10%) |
Voltage | 120 Vac (+10, -15%) |
Shipping and Storage Temperature Range (F) | -40 F to +140 F |
Shipping and Storage Temperature Range (C) | -40 C to +60 C |
Flame Establishing Period – Pilot | 4 sec or 10 sec |
Flame Establishing Period – Main | 10 sec or Intermittent |
Interlocks | Lockout |
Preignition | Yes |
PrePurge | Determined by ST7800A Purge Timer Card |
Early Spark Termination | Yes, 5 sec |
Required Components | Q7800A,B Universal Wiring Subbases. R7847, R7848, R7849, R7851, R7852, R7861, or R7886 Flame Signal Amplifier. ST7800A Plug-in Purge Timer Card. |
Pilot Type | interrupted |
Vibration | 5 G environment |
Information About RM7838B1013
Features
Functions include purge, burner pilot startup, flame supervision, system status indication, system or self diagnosis and troubleshooting.
Delays admission of fuel to combustion chamber until pilot flame has been proven and then monitors the flame through the run period while providing system status indication.
Includes Keyboard Display Module.
Five LEDs provide sequence information.
Intermittent pilot valve.
Interchangeable plug-in flame amplifier.
Access for external electrical voltage checks.
Nonvolatile memory retains history files and lockout status after loss of power.
Selectable pilot flame establishing period.
Provides application flexibility and optional communication interface capability.
Compatible with existing Honeywell flame detectors.
Manufacturer information
Honeywell, a global technology leader, specializes in diverse industries, including aerospace, automation, and safety solutions. With a legacy spanning over a century, Honeywell continues to innovate and provide cutting-edge technologies for a safer, more sustainable world. Their commitment to quality and excellence has made them a trusted brand worldwide.