Product Overview
The Honeywell RM7890 A 1056 Burner Control is engineered to provide safe start-up, flame monitoring, and system shut-down ...  Read more
We accept:
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
warranty
IQElectro 2-Year Warranty
Warranty for Product #: RM7890 A
IQElectro offers a free 2-year warranty on all products. You can trust that every purchase is a reliable investment in the future of your company. Warranty Terms
2-3 Day Free Shipping
Packed Ready to Ship
24/7 Expert Support
Return within 30-Days
IQElectro LLC BBB Business Review
IQElectro is Not an authorized distributor for Honeywell
Original Manufacturer's Warranty Not Covered, This Product is SURPLUS.

Product Description P/N: RM7890 A

Description / Specifications

Description 

The Honeywell RM7890 A is an advanced On/Off primary burner control unit designed for safety monitoring of industrial gas and oil burners. Engineered to provide reliable flame safeguard and sequencing for single or dual fuel burners, it supports an extensive set of operational diagnostics and annunciation features. 

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category
Burner Management Systems
Part Number RM7890 A
Subcategory Flame Safeguard Controllers
Application On/Off Primary Control
Voltage 120 VAC
Pilot Flame Establishing Period 4 sec or 10 sec
Main Flame Establishing Period Intermittent
Interlocks Selectable (Running, Lockout)
Display Included No
Mounting Panel-mounted
Power Consumption 6 VA
Weight 2.5 lbs

  

 

Information About RM7890 A

The RM7890 A is part of Honeywell’s 7800 Series burner control family and is configured as a primary On/Off controller for automatic burner sequencing. It supports burner safety management through integrated fault annunciation LEDs and retains operation history after power loss via nonvolatile memory. The controller operates with intermittent pilot systems, offers selectable interlock options, and supports remote annunciation for system alerts. Advanced modular expandability allows integration with keyboard displays and remote reset modules for greater flexibility in complex systems.

Key Features:

  • Integrated self-diagnostics with blinking LED fault annunciation.
  • Supports modular accessories like keyboard displays and remote display modules.
  • Intermittent pilot operation with 4 or 10-second flame establishing period.
  • Stores sequence and alarm history through nonvolatile memory.
  • Selectable recycle or lockout based on flame/airflow loss.
  • Compatible with plug-in flame amplifiers and shutter drives.
  • Airflow switch check and delayed main valve control.
  • Designed for panel mounting with screw terminal connections.
  • Fully programmable post-purge and interlock configuration.

The RM7890 A ensures safe and precise burner operation by integrating intelligent fault detection and modular adaptability.

IQElectro is not an authorized distributor.
IQElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply. IQElectro sells SURPLUS only and DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Description / Specifications

Description 

The Honeywell RM7890 A is an advanced On/Off primary burner control unit designed for safety monitoring of industrial gas and oil burners. Engineered to provide reliable flame safeguard and sequencing for single or dual fuel burners, it supports an extensive set of operational diagnostics and annunciation features. 

 

 

Technical Specifications 

Condition New/Never Used Surplus
Brand Honeywell
Category
Burner Management Systems
Part Number RM7890 A
Subcategory Flame Safeguard Controllers
Application On/Off Primary Control
Voltage 120 VAC
Pilot Flame Establishing Period 4 sec or 10 sec
Main Flame Establishing Period Intermittent
Interlocks Selectable (Running, Lockout)
Display Included No
Mounting Panel-mounted
Power Consumption 6 VA
Weight 2.5 lbs

  

 

Information About RM7890 A

The RM7890 A is part of Honeywell’s 7800 Series burner control family and is configured as a primary On/Off controller for automatic burner sequencing. It supports burner safety management through integrated fault annunciation LEDs and retains operation history after power loss via nonvolatile memory. The controller operates with intermittent pilot systems, offers selectable interlock options, and supports remote annunciation for system alerts. Advanced modular expandability allows integration with keyboard displays and remote reset modules for greater flexibility in complex systems.

Key Features:

  • Integrated self-diagnostics with blinking LED fault annunciation.
  • Supports modular accessories like keyboard displays and remote display modules.
  • Intermittent pilot operation with 4 or 10-second flame establishing period.
  • Stores sequence and alarm history through nonvolatile memory.
  • Selectable recycle or lockout based on flame/airflow loss.
  • Compatible with plug-in flame amplifiers and shutter drives.
  • Airflow switch check and delayed main valve control.
  • Designed for panel mounting with screw terminal connections.
  • Fully programmable post-purge and interlock configuration.

The RM7890 A ensures safe and precise burner operation by integrating intelligent fault detection and modular adaptability.

Check Out These Related Products

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)