RM7895A1030 | Honeywell Fulton RM7800 Primary Burner Control
- Regular price
- $961.40
- Sale price
- $961.40
- Regular price
-
Couldn't load pickup availability
Product Description P/N: RM7895A1030
Description
The Honeywell Fulton RM7895A1030 is an on-off primary burner control designed for safe and reliable burner sequencing within RM7800 flame safeguard systems. It operates on 120 VAC and supports intermittent pilot operation with integrated airflow safety checks and prepurge capability.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | Flame Safeguard & Burner Controls |
| Part Number | RM7895A1030 |
| Subcategory | Primary Burner Controls |
| Product Series | RM7800 (Fulton Edition) |
| Control Type | On-Off Primary Burner Control |
| Supply Voltage | 120 VAC (+10%, -15%) |
| Frequency | 50/60 Hz (±10%) |
| Pilot Type | Intermittent |
| Pilot Flame Establishing Period | 4 or 10 Seconds (Limited) |
| Main Flame Establishing Period | Intermittent |
| Prepurge Control | ST7800A Purge Timer Card |
| Airflow Switch Check | Included |
| Interlocks | Selectable |
| Compatible Flame Amplifiers | R7847, R7848, R7849, R7851, R7852, R7861, R7886 |
| Required Subbase | Q7800A or Q7800B |
| Vibration Tolerance | 5 G Environment |
| Storage Temperature | -40 to +140 °F (-40 to +60 °C) |
| Weight | 1 lb 15 oz (0.9 kg) |
Information About RM7895A1030
The RM7895A1030 is part of the Honeywell RM7800 Series, specifically configured for Fulton burner applications requiring dependable on-off combustion control. It coordinates burner startup, flame supervision, and shutdown while supporting configurable safety interlocks and airflow verification. The module operates with interchangeable flame amplifiers and external purge timing cards to allow system flexibility. Nonvolatile memory preserves operating history and sequencing data to assist with diagnostics and maintenance.
Key Features
- Automatic Burner Sequencing: Controls safe startup, operation, and shutdown of on-off burner systems.
- Prepurge Capability: Supports controlled prepurge timing through the ST7800A purge timer card.
- Intermittent Pilot Support: Manages pilot and main flame establishing periods for compliant burner operation.
- Dynamic Airflow Verification: Includes airflow switch checking to confirm safe combustion conditions.
- Modular Flame Detection: Accepts multiple interchangeable flame amplifiers for application flexibility.
- Integrated Diagnostics: Five LED indicators provide real-time status, sequence, and fault information.
- Nonvolatile Memory Storage: Retains history and sequencing data after power interruptions.
The RM7895A1030 delivers the reliability and precision required for safe primary burner control in commercial and industrial combustion systems.
Description
The Honeywell Fulton RM7895A1030 is an on-off primary burner control designed for safe and reliable burner sequencing within RM7800 flame safeguard systems. It operates on 120 VAC and supports intermittent pilot operation with integrated airflow safety checks and prepurge capability.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | Flame Safeguard & Burner Controls |
| Part Number | RM7895A1030 |
| Subcategory | Primary Burner Controls |
| Product Series | RM7800 (Fulton Edition) |
| Control Type | On-Off Primary Burner Control |
| Supply Voltage | 120 VAC (+10%, -15%) |
| Frequency | 50/60 Hz (±10%) |
| Pilot Type | Intermittent |
| Pilot Flame Establishing Period | 4 or 10 Seconds (Limited) |
| Main Flame Establishing Period | Intermittent |
| Prepurge Control | ST7800A Purge Timer Card |
| Airflow Switch Check | Included |
| Interlocks | Selectable |
| Compatible Flame Amplifiers | R7847, R7848, R7849, R7851, R7852, R7861, R7886 |
| Required Subbase | Q7800A or Q7800B |
| Vibration Tolerance | 5 G Environment |
| Storage Temperature | -40 to +140 °F (-40 to +60 °C) |
| Weight | 1 lb 15 oz (0.9 kg) |
Information About RM7895A1030
The RM7895A1030 is part of the Honeywell RM7800 Series, specifically configured for Fulton burner applications requiring dependable on-off combustion control. It coordinates burner startup, flame supervision, and shutdown while supporting configurable safety interlocks and airflow verification. The module operates with interchangeable flame amplifiers and external purge timing cards to allow system flexibility. Nonvolatile memory preserves operating history and sequencing data to assist with diagnostics and maintenance.
Key Features
- Automatic Burner Sequencing: Controls safe startup, operation, and shutdown of on-off burner systems.
- Prepurge Capability: Supports controlled prepurge timing through the ST7800A purge timer card.
- Intermittent Pilot Support: Manages pilot and main flame establishing periods for compliant burner operation.
- Dynamic Airflow Verification: Includes airflow switch checking to confirm safe combustion conditions.
- Modular Flame Detection: Accepts multiple interchangeable flame amplifiers for application flexibility.
- Integrated Diagnostics: Five LED indicators provide real-time status, sequence, and fault information.
- Nonvolatile Memory Storage: Retains history and sequencing data after power interruptions.
The RM7895A1030 delivers the reliability and precision required for safe primary burner control in commercial and industrial combustion systems.