Product Description P/N: RM7895B1013
Description
The Honeywell RM7895B1013 is an on/off primary burner control module designed to manage automatic burner sequencing with prepurge and intermittent pilot operation. It operates on 120 VAC and incorporates dynamic airflow safety checks to support reliable flame supervision and system protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | Flame Safeguard & Burner Controls |
| Part Number | RM7895B1013 |
| Subcategory | Burner Control Modules |
| Product Series | 7800 Series |
| Control Type | On/Off Primary Control |
| Supply Voltage | 120 VAC |
| Frequency | 50/60 Hz |
| Pilot Type | Intermittent |
| Flame Establishing Period | 4 to 10 Seconds |
| Prepurge | Required (External Timer) |
| Airflow Monitoring | Dynamic Airflow Switch Check |
| Interlocks | Selectable |
| Flame Amplifier | Interchangeable Plug-In Type |
| Indicators | Five LED Status Indicators |
| Memory Type | Nonvolatile Memory |
| Mounting | Plug-In Relay Module with Subbase |
| Operating Function | Burner Sequencing and Flame Supervision |
| Weight | 2.10 lbs |
Information About RM7895B1013
The RM7895B1013 is part of Honeywell’s 7800 Series flame safeguard controls developed for commercial and industrial burner applications. It provides coordinated burner sequencing, flame monitoring, and safety interlock management using modular components such as a required subbase, flame amplifier, and prepurge timer. The control supports system diagnostics, historical data retention, and optional local or remote annunciation through compatible display and communication modules. Its architecture allows flexible configuration to meet a wide range of combustion system requirements.
Key Features
- Automatic Burner Sequencing: Manages safe startup, operation, and shutdown of on/off burner systems.
- Dynamic Airflow Safety Check: Verifies airflow switch status to ensure proper combustion air conditions.
- Intermittent Pilot Operation: Supports intermittent pilot systems with selectable flame establishing periods.
- Modular System Design: Uses interchangeable flame amplifiers and external subbase components for flexibility.
- Integrated Diagnostics: Provides system status, fault information, and troubleshooting support via LEDs and optional displays.
- Nonvolatile Memory Storage: Retains operating history and sequencing status after loss of power.
- Selectable Flame Response: Allows configuration for relight or lockout on loss of flame.
The RM7895B1013 delivers the reliability and precision required for safe burner management in commercial and industrial combustion systems.
Description
The Honeywell RM7895B1013 is an on/off primary burner control module designed to manage automatic burner sequencing with prepurge and intermittent pilot operation. It operates on 120 VAC and incorporates dynamic airflow safety checks to support reliable flame supervision and system protection.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Honeywell |
| Category | Flame Safeguard & Burner Controls |
| Part Number | RM7895B1013 |
| Subcategory | Burner Control Modules |
| Product Series | 7800 Series |
| Control Type | On/Off Primary Control |
| Supply Voltage | 120 VAC |
| Frequency | 50/60 Hz |
| Pilot Type | Intermittent |
| Flame Establishing Period | 4 to 10 Seconds |
| Prepurge | Required (External Timer) |
| Airflow Monitoring | Dynamic Airflow Switch Check |
| Interlocks | Selectable |
| Flame Amplifier | Interchangeable Plug-In Type |
| Indicators | Five LED Status Indicators |
| Memory Type | Nonvolatile Memory |
| Mounting | Plug-In Relay Module with Subbase |
| Operating Function | Burner Sequencing and Flame Supervision |
| Weight | 2.10 lbs |
Information About RM7895B1013
The RM7895B1013 is part of Honeywell’s 7800 Series flame safeguard controls developed for commercial and industrial burner applications. It provides coordinated burner sequencing, flame monitoring, and safety interlock management using modular components such as a required subbase, flame amplifier, and prepurge timer. The control supports system diagnostics, historical data retention, and optional local or remote annunciation through compatible display and communication modules. Its architecture allows flexible configuration to meet a wide range of combustion system requirements.
Key Features
- Automatic Burner Sequencing: Manages safe startup, operation, and shutdown of on/off burner systems.
- Dynamic Airflow Safety Check: Verifies airflow switch status to ensure proper combustion air conditions.
- Intermittent Pilot Operation: Supports intermittent pilot systems with selectable flame establishing periods.
- Modular System Design: Uses interchangeable flame amplifiers and external subbase components for flexibility.
- Integrated Diagnostics: Provides system status, fault information, and troubleshooting support via LEDs and optional displays.
- Nonvolatile Memory Storage: Retains operating history and sequencing status after loss of power.
- Selectable Flame Response: Allows configuration for relight or lockout on loss of flame.
The RM7895B1013 delivers the reliability and precision required for safe burner management in commercial and industrial combustion systems.