S12-403P8LU | Reliance Electric 2HP 390-480V AC Drive
- Regular price
- $772.00
- Sale price
- $772.00
- Regular price
-
Do you need help?
Product Description P/N: S12-403P8LU
Description
S12-403P8LU is an AC SP120 drive that is manufactured by Reliance Electric. The voltage rating is 460 VAC for this three-phase drive. The enclosure type is a protected IP20 chassis. This drive includes a keypad. The output current is 3.8 A. The horsepower is 2.0 HP (1.5 kW) at 460 V.
Technical Specifications
Brand | Reliance Electric |
Category | Drives |
Part Number | S12-403P8LU |
Subcategory | Drive |
Series | SP120 |
HP | 2 HP |
Input Voltage | 390-480 VAC |
Enclosure | Protected Chassis (IP 20) |
Keypad/Display | Keypad |
kW | 1.5kW |
Hz | 50/60Hz |
Labeling | UL Listed, IEC Certified |
Information About S12-403P8LU
There are a number of adjustable parameters on the drive. The Automatic Start After a Fault parameters include the Restart Mode Select, the Power Loss Time, and the Restart Time. The range of b01 (Restart Mode Select) is 00 to 03, and the factory default is 00. The range of b02 (Power Loss Time) is 0.3 to 25.0 seconds, and the factory default is 1.0 second. The range of b03 (Restart Time) is 0.3 to 100.0 seconds, and the factory default is 1.0 second. The Electronic Motor Protection parameters include the Motor Overload Current and the Motor Overload Select. The range of b12 (Motor Overload Current) is 5 to 120% of the rated current amps, and the factory default is 115% of the drive rating. The range of b13 (Motor Overload Select) is 00 to 01, and the factory default is 01.
The Current Limit parameters include the Current Limit Select, the Current Limit, and the Current Limit Decel Time. The range of b21 (Current Limit Select) is 00 to 02, and the factory default is 01. The range of b22 (Current Limit) is 50 to 150% of the rated current amps, and the factory default is 150% of the drive rating. The range of b23 (Current Limit Decel Time) is 0.3 to 30.0 seconds, and the factory default is 1.0 second.
Manufacturer information
Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.
Description
S12-403P8LU is an AC SP120 drive that is manufactured by Reliance Electric. The voltage rating is 460 VAC for this three-phase drive. The enclosure type is a protected IP20 chassis. This drive includes a keypad. The output current is 3.8 A. The horsepower is 2.0 HP (1.5 kW) at 460 V.
Technical Specifications
Brand | Reliance Electric |
Category | Drives |
Part Number | S12-403P8LU |
Subcategory | Drive |
Series | SP120 |
HP | 2 HP |
Input Voltage | 390-480 VAC |
Enclosure | Protected Chassis (IP 20) |
Keypad/Display | Keypad |
kW | 1.5kW |
Hz | 50/60Hz |
Labeling | UL Listed, IEC Certified |
Information About S12-403P8LU
There are a number of adjustable parameters on the drive. The Automatic Start After a Fault parameters include the Restart Mode Select, the Power Loss Time, and the Restart Time. The range of b01 (Restart Mode Select) is 00 to 03, and the factory default is 00. The range of b02 (Power Loss Time) is 0.3 to 25.0 seconds, and the factory default is 1.0 second. The range of b03 (Restart Time) is 0.3 to 100.0 seconds, and the factory default is 1.0 second. The Electronic Motor Protection parameters include the Motor Overload Current and the Motor Overload Select. The range of b12 (Motor Overload Current) is 5 to 120% of the rated current amps, and the factory default is 115% of the drive rating. The range of b13 (Motor Overload Select) is 00 to 01, and the factory default is 01.
The Current Limit parameters include the Current Limit Select, the Current Limit, and the Current Limit Decel Time. The range of b21 (Current Limit Select) is 00 to 02, and the factory default is 01. The range of b22 (Current Limit) is 50 to 150% of the rated current amps, and the factory default is 150% of the drive rating. The range of b23 (Current Limit Decel Time) is 0.3 to 30.0 seconds, and the factory default is 1.0 second.
Manufacturer information
Reliance Electric, a pioneering electrical equipment manufacturer, was founded in 1904. Acquired by Rockwell Automation, it specialized in motors, drives, and industrial automation solutions. Known for innovation, Reliance played a key role in advancing industrial technology.