EDB34035 | Schneider Electric Square D E-Frame 3-Pole Mini Circuit Breaker 35 A 480Y/277 Vac
- Regular price
- $219.00
- Sale price
- $219.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: EDB34035
Description
The Schneider Electric EDB34035 is a 3-pole E-Frame mini molded case circuit breaker rated at 35 A for use in NF panelboards. It provides thermal-magnetic protection against overloads and short circuits in lighting and power distribution systems up to 480Y/277 Vac.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | EDB34035 |
| Subcategory | Molded Case Circuit Breaker |
| Series / Range | 125 A Frame EDB–EGB–EJB |
| Frame Type | E-Frame |
| Rated Current | 35 A |
| Number of Poles | 3 |
| Maximum Operating Voltage | 480Y/277 Vac |
| Trip Unit Technology | Thermal-magnetic |
| Trip Unit Rating | 1800 A |
| Holding Current | 630 A |
| Protection Type | Overload, Short-circuit |
| Breaking Capacity Code | D |
| Mounting Mode | Bolt-on |
| Product Destination | NF panelboard |
| Local Signaling | Trip indicator |
| Conductor Size | AWG 12…2/0 Al, AWG 14…2/0 Cu |
| Height | 5.66 in (143.76 mm) |
| Width | 2.94 in (74.68 mm) |
| Depth | 4.05 in (102.87 mm) |
| Weight | 4 lb (1.81 kg) |
Information About EDB34035
The EDB34035 is a mini molded case circuit breaker from Schneider Electric’s Square D E-Frame family, engineered specifically for NF panelboard applications. Its compact bolt-on design supports efficient installation while maintaining robust electrical and mechanical performance. The breaker incorporates a thermal-magnetic trip unit to deliver dependable response to both sustained overloads and instantaneous short-circuit conditions. Designed for demanding lighting and distribution environments, it supports compliance with application requirements such as HID and HACR ratings.
Key Features:
- E-Frame mini MCCB design: Provides compact, panelboard-optimized protection within Square D NF panelboards.
- Thermal-magnetic trip unit: Ensures accurate long-time overload protection combined with fast magnetic short-circuit response.
- 35 A, 3-pole configuration: Supports three-phase circuits used in lighting and power distribution applications.
- High voltage capability: Rated for operation up to 480Y/277 Vac to accommodate common commercial systems.
- Integrated trip indicator: Offers clear visual indication when a trip event has occurred for faster diagnostics.
- HID and HACR ratings: Suitable for high-intensity discharge lighting and HVAC-related loads.
- Bolt-on mounting method: Enables secure mechanical attachment and reliable electrical contact within panelboards.
The EDB34035 delivers the reliability and precision required for controlled protection of three-phase lighting and distribution circuits in NF panelboard systems.
Description
The Schneider Electric EDB34035 is a 3-pole E-Frame mini molded case circuit breaker rated at 35 A for use in NF panelboards. It provides thermal-magnetic protection against overloads and short circuits in lighting and power distribution systems up to 480Y/277 Vac.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | EDB34035 |
| Subcategory | Molded Case Circuit Breaker |
| Series / Range | 125 A Frame EDB–EGB–EJB |
| Frame Type | E-Frame |
| Rated Current | 35 A |
| Number of Poles | 3 |
| Maximum Operating Voltage | 480Y/277 Vac |
| Trip Unit Technology | Thermal-magnetic |
| Trip Unit Rating | 1800 A |
| Holding Current | 630 A |
| Protection Type | Overload, Short-circuit |
| Breaking Capacity Code | D |
| Mounting Mode | Bolt-on |
| Product Destination | NF panelboard |
| Local Signaling | Trip indicator |
| Conductor Size | AWG 12…2/0 Al, AWG 14…2/0 Cu |
| Height | 5.66 in (143.76 mm) |
| Width | 2.94 in (74.68 mm) |
| Depth | 4.05 in (102.87 mm) |
| Weight | 4 lb (1.81 kg) |
Information About EDB34035
The EDB34035 is a mini molded case circuit breaker from Schneider Electric’s Square D E-Frame family, engineered specifically for NF panelboard applications. Its compact bolt-on design supports efficient installation while maintaining robust electrical and mechanical performance. The breaker incorporates a thermal-magnetic trip unit to deliver dependable response to both sustained overloads and instantaneous short-circuit conditions. Designed for demanding lighting and distribution environments, it supports compliance with application requirements such as HID and HACR ratings.
Key Features:
- E-Frame mini MCCB design: Provides compact, panelboard-optimized protection within Square D NF panelboards.
- Thermal-magnetic trip unit: Ensures accurate long-time overload protection combined with fast magnetic short-circuit response.
- 35 A, 3-pole configuration: Supports three-phase circuits used in lighting and power distribution applications.
- High voltage capability: Rated for operation up to 480Y/277 Vac to accommodate common commercial systems.
- Integrated trip indicator: Offers clear visual indication when a trip event has occurred for faster diagnostics.
- HID and HACR ratings: Suitable for high-intensity discharge lighting and HVAC-related loads.
- Bolt-on mounting method: Enables secure mechanical attachment and reliable electrical contact within panelboards.
The EDB34035 delivers the reliability and precision required for controlled protection of three-phase lighting and distribution circuits in NF panelboard systems.