Product Description P/N: HGL36150
Description
The Schneider Electric HGL36150 is a 3-pole molded case circuit breaker designed to protect distribution lines from overloads and short circuits in low-voltage power systems. It uses a thermal-magnetic trip unit and supports reliable interruption performance in demanding commercial and industrial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | HGL36150 |
| Subcategory | Molded Case Circuit Breaker |
| Range | PowerPacT |
| Product Name | PowerPacT H |
| Product Type | Circuit Breaker |
| Device Application | Distribution Line |
| Rated Current | 150 A |
| Number of Poles | 3 |
| Protected Poles Description | 3t |
| Control Type | Toggle |
| Breaking Capacity Code | G |
| Rated Operational Voltage | 690 V AC, 50/60 Hz (IEC 60947-3) |
| Network Frequency | 50/60 Hz |
| Impulse Withstand Voltage | 8 kV (IEC 60947-2) |
| Trip Unit Technology | Thermal-Magnetic |
| Magnetic Tripping Current | 1700 A |
| Magnetic Hold Current | 900 A |
| Continuous Current Rating | 80% |
| Rated Insulation Voltage | 750 V (IEC 60947-2) |
| Suitability for Isolation | Yes (IEC 60947-2) |
| Utilisation Category | Category A |
| AWG Gauge | AWG 14 to AWG 3/0 Aluminum/Copper |
| Local Signalling | OFF / Trip Indicator (Green) |
| Mounting Mode | Unit Mount Lug |
| Mounting Support | Lug |
| Wire Stripping Length | 0.63 in (16 mm) |
| Color | Black |
| Height | 6.42 in (163 mm) |
| Width | 4.09 in (104 mm) |
| Depth | 3.39 in (86 mm) |
| Weight | 4.85 lb (2.2 kg) |
Information About HGL36150
The HGL36150 is part of the Schneider Electric PowerPacT H-Frame family, developed for reliable protection of low-voltage distribution systems. Its molded case construction and H-Frame design support stable performance under high electrical and mechanical stress. The breaker incorporates a thermal-magnetic trip unit that provides long-term overload protection and instantaneous response to short-circuit faults. Typical installations include commercial and industrial distribution panels where compact design, standardized IEC compliance, and dependable interruption capability are required.
Key Features:
- PowerPacT H-Frame Design: Engineered for compact, high-performance protection in low-voltage distribution systems.
- Thermal-Magnetic Trip Unit: Provides consistent overload protection and fast short-circuit interruption.
- Dual-Break Rotating Contacts: Reduces peak let-through current during fault conditions to enhance system protection.
- 18 kA Breaking Capacity: Rated to interrupt fault currents at 600 VAC in demanding electrical environments.
- Integral Push-to-Trip Button: Allows manual tripping for testing and maintenance operations.
- Three-Pole Configuration: Supports protection of three-phase distribution circuits.
- Line and Load Lugs Included: Enables secure and efficient conductor termination on both sides of the breaker.
- 80% Continuous Rating: Suitable for continuous-duty applications within rated operating limits.
The HGL36150 delivers the reliability and precision required for protecting low-voltage distribution circuits in commercial and industrial power systems.
Description
The Schneider Electric HGL36150 is a 3-pole molded case circuit breaker designed to protect distribution lines from overloads and short circuits in low-voltage power systems. It uses a thermal-magnetic trip unit and supports reliable interruption performance in demanding commercial and industrial environments.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Schneider Electric |
| Category | Circuit Breaker |
| Part Number | HGL36150 |
| Subcategory | Molded Case Circuit Breaker |
| Range | PowerPacT |
| Product Name | PowerPacT H |
| Product Type | Circuit Breaker |
| Device Application | Distribution Line |
| Rated Current | 150 A |
| Number of Poles | 3 |
| Protected Poles Description | 3t |
| Control Type | Toggle |
| Breaking Capacity Code | G |
| Rated Operational Voltage | 690 V AC, 50/60 Hz (IEC 60947-3) |
| Network Frequency | 50/60 Hz |
| Impulse Withstand Voltage | 8 kV (IEC 60947-2) |
| Trip Unit Technology | Thermal-Magnetic |
| Magnetic Tripping Current | 1700 A |
| Magnetic Hold Current | 900 A |
| Continuous Current Rating | 80% |
| Rated Insulation Voltage | 750 V (IEC 60947-2) |
| Suitability for Isolation | Yes (IEC 60947-2) |
| Utilisation Category | Category A |
| AWG Gauge | AWG 14 to AWG 3/0 Aluminum/Copper |
| Local Signalling | OFF / Trip Indicator (Green) |
| Mounting Mode | Unit Mount Lug |
| Mounting Support | Lug |
| Wire Stripping Length | 0.63 in (16 mm) |
| Color | Black |
| Height | 6.42 in (163 mm) |
| Width | 4.09 in (104 mm) |
| Depth | 3.39 in (86 mm) |
| Weight | 4.85 lb (2.2 kg) |
Information About HGL36150
The HGL36150 is part of the Schneider Electric PowerPacT H-Frame family, developed for reliable protection of low-voltage distribution systems. Its molded case construction and H-Frame design support stable performance under high electrical and mechanical stress. The breaker incorporates a thermal-magnetic trip unit that provides long-term overload protection and instantaneous response to short-circuit faults. Typical installations include commercial and industrial distribution panels where compact design, standardized IEC compliance, and dependable interruption capability are required.
Key Features:
- PowerPacT H-Frame Design: Engineered for compact, high-performance protection in low-voltage distribution systems.
- Thermal-Magnetic Trip Unit: Provides consistent overload protection and fast short-circuit interruption.
- Dual-Break Rotating Contacts: Reduces peak let-through current during fault conditions to enhance system protection.
- 18 kA Breaking Capacity: Rated to interrupt fault currents at 600 VAC in demanding electrical environments.
- Integral Push-to-Trip Button: Allows manual tripping for testing and maintenance operations.
- Three-Pole Configuration: Supports protection of three-phase distribution circuits.
- Line and Load Lugs Included: Enables secure and efficient conductor termination on both sides of the breaker.
- 80% Continuous Rating: Suitable for continuous-duty applications within rated operating limits.
The HGL36150 delivers the reliability and precision required for protecting low-voltage distribution circuits in commercial and industrial power systems.