Description
The Siemens FT2015-R3 is a red remote display terminal with integrated system controls for Cerberus PRO fire alarm systems. It provides a backlit LCD and dedicated status LEDs for displaying alarm, gas alarm, supervisory, and trouble events, with local controls for acknowledging, silencing, and resetting the system.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Detection |
| Part Number | FT2015-R3 |
| Product Type | Remote Display Terminal with Control |
| System Compatibility | Siemens Cerberus PRO |
| Display | 2 × 4.75 in. backlit LCD |
| Controls | 3 system control buttons + 3 programmable buttons |
| Key Switch | Integral key switch |
| Communication | RS-485 via FCA2016-U1 |
| Wiring | Class A Style 6 / Class B Style 4 |
| Power Requirement | 24 VDC @ 55 mA |
| Mounting | 2-gang or 4-inch square electrical box |
| Dimensions | Approximately 12.25 × 9 × 2.5 in. |
| Operating Environment | Indoor, dry locations |
| Operating Temperature | 32 ± 3°F to 120 ± 3°F (0 ± 2°C to 49 ± 2°C) |
| Approvals | UL 864, ULC, FM, CSFM, NYC Fire Department |
| Weight | 2.092 kg |
Information About FT2015-R3
The FT2015-R3 is part of the Siemens Cerberus PRO remote display terminal series and includes three control buttons plus an integral key switch. Its 2 × 4.75-inch backlit LCD displays event type, zone, custom messages, zone usage, acknowledgment status, and the total number of active events. Communication with compatible Cerberus PRO fire alarm control panels is provided through the FCA2016-U1 RS-485 interface, supporting Class A or Class B wiring. The terminal operates from 24 VDC and can be mounted in a two-gang or 4-inch square electrical box.
Key Features:
- Remote Display: Provides remote indication of Cerberus PRO system events.
- Backlit LCD: Displays detailed alphanumeric event and system information.
- Status LEDs: Dedicated indicators show alarm, gas alarm, supervisory, trouble, power, ground-fault, and audible circuit status.
- System Controls: Three control buttons support event acknowledgment, audible circuit silencing, and system reset.
- Key Switch: Integral key switch enables operation of the system control buttons.
- RS-485 Communication: Connects to Cerberus PRO panels through the FCA2016-U1 interface.
- Wiring Support: Supports Class A Style 6 and Class B Style 4 configurations.
- Local Sounder: Provides local audible indication when system events are present.
The FT2015-R3 delivers the reliability and precision required for remote fire alarm system monitoring and control.
Description
The Siemens FT2015-R3 is a red remote display terminal with integrated system controls for Cerberus PRO fire alarm systems. It provides a backlit LCD and dedicated status LEDs for displaying alarm, gas alarm, supervisory, and trouble events, with local controls for acknowledging, silencing, and resetting the system.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Detection |
| Part Number | FT2015-R3 |
| Product Type | Remote Display Terminal with Control |
| System Compatibility | Siemens Cerberus PRO |
| Display | 2 × 4.75 in. backlit LCD |
| Controls | 3 system control buttons + 3 programmable buttons |
| Key Switch | Integral key switch |
| Communication | RS-485 via FCA2016-U1 |
| Wiring | Class A Style 6 / Class B Style 4 |
| Power Requirement | 24 VDC @ 55 mA |
| Mounting | 2-gang or 4-inch square electrical box |
| Dimensions | Approximately 12.25 × 9 × 2.5 in. |
| Operating Environment | Indoor, dry locations |
| Operating Temperature | 32 ± 3°F to 120 ± 3°F (0 ± 2°C to 49 ± 2°C) |
| Approvals | UL 864, ULC, FM, CSFM, NYC Fire Department |
| Weight | 2.092 kg |
Information About FT2015-R3
The FT2015-R3 is part of the Siemens Cerberus PRO remote display terminal series and includes three control buttons plus an integral key switch. Its 2 × 4.75-inch backlit LCD displays event type, zone, custom messages, zone usage, acknowledgment status, and the total number of active events. Communication with compatible Cerberus PRO fire alarm control panels is provided through the FCA2016-U1 RS-485 interface, supporting Class A or Class B wiring. The terminal operates from 24 VDC and can be mounted in a two-gang or 4-inch square electrical box.
Key Features:
- Remote Display: Provides remote indication of Cerberus PRO system events.
- Backlit LCD: Displays detailed alphanumeric event and system information.
- Status LEDs: Dedicated indicators show alarm, gas alarm, supervisory, trouble, power, ground-fault, and audible circuit status.
- System Controls: Three control buttons support event acknowledgment, audible circuit silencing, and system reset.
- Key Switch: Integral key switch enables operation of the system control buttons.
- RS-485 Communication: Connects to Cerberus PRO panels through the FCA2016-U1 interface.
- Wiring Support: Supports Class A Style 6 and Class B Style 4 configurations.
- Local Sounder: Provides local audible indication when system events are present.
The FT2015-R3 delivers the reliability and precision required for remote fire alarm system monitoring and control.