Product Description P/N: ILT-1
Description
The Siemens ILT-1 is an intelligent thermal detector designed to detect excessive heat in compatible Cerberus Pyrotronics addressable fire alarm systems. It combines a 135°F rate-compensated/fixed-temperature sensor with microprocessor-based addressing, supervision, and bidirectional panel communication.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Alarm Systems |
| Part Number | ILT-1 |
| Subcategory | Intelligent Heat Detectors |
| Product Type | Intelligent Thermal Detector |
| Detection Type | Rate-Compensated / Fixed Temperature |
| Temperature Rating | 135°F (57°C) |
| Operation | Two-Wire |
| Technology | Microprocessor-Based |
| Communication | Bidirectional Addressable |
| Compatible Systems | Cerberus Pyrotronics IXL, MXL, XL3 |
| Programming Device | SensorLINK FPI-32 |
| Alarm Indication | Integrated LED |
| Mounting Base | DB-3S Surface Mounting Base or compatible ILT-series base |
| Approvals | UL Listed, ULC Listed, CSFM, NYMEA |
| Weight | 1.0 lb (0.45 kg) |
Information About ILT-1
The ILT-1 is a Siemens/Cerberus Pyrotronics intelligent two-wire thermal detector compatible with IXL, MXL, and XL3 fire alarm control panels. Its sensing assembly uses a 135°F (57°C) rate-compensation/fixed-temperature mechanism intended for areas where heat detection is preferable to other detection methods. An integrated microcomputer stores address and operating information while supporting supervised bidirectional communication with the associated control panel. Electronic addressing and functional testing are performed with the SensorLINK FPI-32 field programmer/tester, eliminating mechanical address switches or programming pins.
Key Features:
- 135°F Heat Detection: Uses a 135°F (57°C) rate-compensated/fixed-temperature thermal sensing element.
- Intelligent Addressing: Stores detector identification and address information electronically within the detector.
- Microprocessor-Based Design: Integrated processing supports intelligent detection, supervision, and panel communication.
- Two-Wire Operation: Connects to compatible addressable initiating circuits through a two-wire configuration.
- Bidirectional Communication: Exchanges operating and status information with compatible fire alarm control equipment.
- FPI-32 Programming: Supports electronic addressing and functional testing through the SensorLINK FPI-32 programmer/tester.
- Alarm LED: Integrated LED provides local visual indication when the detector enters an alarm condition.
- Multi-System Compatibility: Designed for compatible Cerberus Pyrotronics IXL, MXL, and XL3 control panels.
The ILT-1 delivers the reliability and precision required for intelligent fixed-temperature heat detection within compatible addressable fire alarm systems.
Description
The Siemens ILT-1 is an intelligent thermal detector designed to detect excessive heat in compatible Cerberus Pyrotronics addressable fire alarm systems. It combines a 135°F rate-compensated/fixed-temperature sensor with microprocessor-based addressing, supervision, and bidirectional panel communication.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Alarm Systems |
| Part Number | ILT-1 |
| Subcategory | Intelligent Heat Detectors |
| Product Type | Intelligent Thermal Detector |
| Detection Type | Rate-Compensated / Fixed Temperature |
| Temperature Rating | 135°F (57°C) |
| Operation | Two-Wire |
| Technology | Microprocessor-Based |
| Communication | Bidirectional Addressable |
| Compatible Systems | Cerberus Pyrotronics IXL, MXL, XL3 |
| Programming Device | SensorLINK FPI-32 |
| Alarm Indication | Integrated LED |
| Mounting Base | DB-3S Surface Mounting Base or compatible ILT-series base |
| Approvals | UL Listed, ULC Listed, CSFM, NYMEA |
| Weight | 1.0 lb (0.45 kg) |
Information About ILT-1
The ILT-1 is a Siemens/Cerberus Pyrotronics intelligent two-wire thermal detector compatible with IXL, MXL, and XL3 fire alarm control panels. Its sensing assembly uses a 135°F (57°C) rate-compensation/fixed-temperature mechanism intended for areas where heat detection is preferable to other detection methods. An integrated microcomputer stores address and operating information while supporting supervised bidirectional communication with the associated control panel. Electronic addressing and functional testing are performed with the SensorLINK FPI-32 field programmer/tester, eliminating mechanical address switches or programming pins.
Key Features:
- 135°F Heat Detection: Uses a 135°F (57°C) rate-compensated/fixed-temperature thermal sensing element.
- Intelligent Addressing: Stores detector identification and address information electronically within the detector.
- Microprocessor-Based Design: Integrated processing supports intelligent detection, supervision, and panel communication.
- Two-Wire Operation: Connects to compatible addressable initiating circuits through a two-wire configuration.
- Bidirectional Communication: Exchanges operating and status information with compatible fire alarm control equipment.
- FPI-32 Programming: Supports electronic addressing and functional testing through the SensorLINK FPI-32 programmer/tester.
- Alarm LED: Integrated LED provides local visual indication when the detector enters an alarm condition.
- Multi-System Compatibility: Designed for compatible Cerberus Pyrotronics IXL, MXL, and XL3 control panels.
The ILT-1 delivers the reliability and precision required for intelligent fixed-temperature heat detection within compatible addressable fire alarm systems.