Siemens NIC-C Fire Alarm HNET and CAN Network Interface Card
- Regular price
- $435.00
- Sale price
- $435.00
- Regular price
-
Couldn't load pickup availability
Product Description P/N: NIC-C
Description
The Siemens NIC-C is a Network Interface Card designed to provide network communication and system data exchange within compatible Siemens fire alarm systems. It supports HNET communication paths and CAN-based connections for coordinating networked control, input, output, and annunciation equipment.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Alarm Systems |
| Part Number | NIC-C |
| Subcategory | Network Interface Cards |
| Product Type | Network Interface Card |
| Network Protocol | HNET |
| Peripheral Communication | CAN |
| HNET Network Output | 8 V Peak-to-Peak Maximum |
| HNET Output Current | 75 mA Maximum During Message Transmission |
| 24 V Backplane Current | 120 mA |
| 24 V Screw Terminal Current | 60 mA |
| 24 V Standby Current | 120 mA |
| Installation Type | Internal System Card |
| Application | Fire Alarm Network Communication |
| Weight | 0.855 lb |
Information About NIC-C
The NIC-C is a Siemens network interface card designed for installation within compatible modular fire safety control systems. It provides network communication between system nodes and supports HNET connections used to exchange fire alarm status, commands, and control information. The card also communicates through CAN connections with compatible modules such as supervised input and output equipment. Its supervised network architecture and defined backplane power requirements allow the NIC-C to function as an integral communication component within distributed fire alarm installations.
Key Features:
- Network Interface Function: Provides communication between compatible Siemens fire alarm system nodes and modules.
- HNET Communication: Supports HNET network pairs for supervised system data transmission.
- CAN Connectivity: Provides CAN communication for compatible peripheral and interface modules.
- Dual HNET Paths: Supports network communication paths used for distributed fire alarm system configurations.
- Controlled Network Output: Each HNET network pair provides up to 8 V peak-to-peak during communication.
- Current-Limited Communication: HNET output is rated at a maximum of 75 mA during message transmission.
- Backplane Integration: Receives operating power through compatible system backplane and terminal connections.
- Modular System Design: Functions as an internal network communication card within supported Siemens fire safety equipment.
The NIC-C delivers the reliability and precision required for network communication and coordinated data exchange within compatible Siemens fire alarm systems.
Description
The Siemens NIC-C is a Network Interface Card designed to provide network communication and system data exchange within compatible Siemens fire alarm systems. It supports HNET communication paths and CAN-based connections for coordinating networked control, input, output, and annunciation equipment.
Technical Specifications
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Fire Alarm Systems |
| Part Number | NIC-C |
| Subcategory | Network Interface Cards |
| Product Type | Network Interface Card |
| Network Protocol | HNET |
| Peripheral Communication | CAN |
| HNET Network Output | 8 V Peak-to-Peak Maximum |
| HNET Output Current | 75 mA Maximum During Message Transmission |
| 24 V Backplane Current | 120 mA |
| 24 V Screw Terminal Current | 60 mA |
| 24 V Standby Current | 120 mA |
| Installation Type | Internal System Card |
| Application | Fire Alarm Network Communication |
| Weight | 0.855 lb |
Information About NIC-C
The NIC-C is a Siemens network interface card designed for installation within compatible modular fire safety control systems. It provides network communication between system nodes and supports HNET connections used to exchange fire alarm status, commands, and control information. The card also communicates through CAN connections with compatible modules such as supervised input and output equipment. Its supervised network architecture and defined backplane power requirements allow the NIC-C to function as an integral communication component within distributed fire alarm installations.
Key Features:
- Network Interface Function: Provides communication between compatible Siemens fire alarm system nodes and modules.
- HNET Communication: Supports HNET network pairs for supervised system data transmission.
- CAN Connectivity: Provides CAN communication for compatible peripheral and interface modules.
- Dual HNET Paths: Supports network communication paths used for distributed fire alarm system configurations.
- Controlled Network Output: Each HNET network pair provides up to 8 V peak-to-peak during communication.
- Current-Limited Communication: HNET output is rated at a maximum of 75 mA during message transmission.
- Backplane Integration: Receives operating power through compatible system backplane and terminal connections.
- Modular System Design: Functions as an internal network communication card within supported Siemens fire safety equipment.
The NIC-C delivers the reliability and precision required for network communication and coordinated data exchange within compatible Siemens fire alarm systems.